Literature DB >> 19944664

Anterior cruciate ligament reconstruction: assessment of the hamstring autograft femoral fixation using the EndoButton CL.

S Plaweski1, J Rossi, P Merloz.   

Abstract

UNLABELLED: The objective of this study was to evaluate the clinical and radiological results of a prospective, continuous series of 105 ACL reconstructions using the STG tendons fixed to the femur by an EndoButton CL, with more than 4 years of follow-up. HYPOTHESIS: The subjective and objective clinical results as well as the radiological results (tunnel enlargement) obtained by a cortical, extra-anatomic femoral fixation are at least equivalent to the results obtained with other types of femoral fixation systems.
MATERIAL AND METHODS: One hundred and five patients aged with a mean 26 years (range, 12-56 years) were operated on for an anterior cruciate ligament rupture using the same technique and by the same operator: four-strand STG fixed to the tibia by a double fixation--BioRCI-HA screw and staple--and on the femur by an EndoButton CL (Smith and Nephew). The results were assessed at 6 months, 1 and 2 years and then at a mean follow-up of 51 months, both clinically (IKDC, Lysholm, KT-1000) and radiologically (Telos laximetry, tunnel position, and morphological analysis).
RESULTS: No complications related to the use of the EndoButton were observed. No additional interference screw was necessary. According to the IKDC laxity classification, 91.4% of the patients were classified in category A or B, nine knees (8.6%) were classified C or D. Four failures required revision with a patellar tendon graft. On the final IKDC score, 63 patients (60%) were classified grade A, 37 grade B (35.3%), four grade C (3.8%), and one grade D (0.9%). On the Telos laximetry, 62 patients (59%) had a differential laxity less than or equal to 2 mm. The mean value was 1.8 mm (range, 0-11). Tibial tunnel enlargement was constant; femoral tunnel enlargement was significant (>2 mm) in 27.6% of the knees. No femoral tunnel diameter modification corresponding to the EndoButton passage was observed. DISCUSSION: The results of this series are comparable to the results of other series. Its reproducibility and the absence of iatrogenic complications for this femoral EndoButton CL fixation make it a top-choice technique, like the corticocancellous graft procedures, but without their disadvantages. No secondary elongation attributable to the EndoButton CL was observed. This femoral fixation procedure appeared necessary and sufficient to providing good mechanical stability for the graft in the femoral tunnel.

Entities:  

Mesh:

Year:  2009        PMID: 19944664     DOI: 10.1016/j.otsr.2009.09.011

Source DB:  PubMed          Journal:  Orthop Traumatol Surg Res        ISSN: 1877-0568            Impact factor:   2.256


  11 in total

1.  A prospective randomized comparison of irradiated and non-irradiated hamstring tendon allograft for ACL reconstruction.

Authors:  Kang Sun; Jihua Zhang; Yan Wang; Cailong Zhang; Changsuo Xia; Tengbo Yu; Shaoqi Tian
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-02-03       Impact factor: 4.342

2.  Long-term outcomes of medial CMI implant versus partial medial meniscectomy in patients with concomitant ACL reconstruction.

Authors:  Erica Bulgheroni; Alberto Grassi; Paolo Bulgheroni; Giulio Maria Marcheggiani Muccioli; Stefano Zaffagnini; Maurilio Marcacci
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-07-04       Impact factor: 4.342

3.  Anterior cruciate ligament reconstruction using a hamstring graft: a retrospective comparison of tunnel widening upon use of two different femoral fixation methods.

Authors:  Musa Ugur Mermerkaya; Ozgur Ahmet Atay; Burak Kaymaz; Senol Bekmez; Fatih Karaaslan; Mahmut Nedim Doral
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-05-13       Impact factor: 4.342

4.  Does an Adjustable-Loop Device Loosen following ACL Reconstruction with a Hamstring Graft? A Retrospective Study with a Follow-Up of Two Years.

Authors:  Mohammad Jesan Khan; Naiyer Asif; Mohd Hadi Aziz; Ariz Raza; Shahzad Anwar; Shibili Nuhmani; Ahmad H Alghadir; Masood Khan
Journal:  J Clin Med       Date:  2022-06-24       Impact factor: 4.964

5.  Prevalence and influence of tibial tunnel widening after isolated anterior cruciate ligament reconstruction using patella-bone-tendon-bone-graft: long-term follow-up.

Authors:  Johannes Struewer; Turgay Efe; Thomas Manfred Frangen; Tim Schwarting; Benjamin Buecking; Steffen Ruchholtz; Karl Friedrich Schüttler; Ewgeni Ziring
Journal:  Orthop Rev (Pavia)       Date:  2012-06-21

6.  Aerobic fitness in professional soccer players after anterior cruciate ligament reconstruction.

Authors:  Adriano Marques de Almeida; Paulo Roberto Santos Silva; André Pedrinelli; Arnaldo J Hernandez
Journal:  PLoS One       Date:  2018-03-22       Impact factor: 3.240

7.  Tunnel widening prevention with the allo-Achilles tendon graft in anterior cruciate ligament reconstruction: Surgical tips and short term followup.

Authors:  Dong Won Suh; Seung Beom Han; Woo Jin Yeo; Won Hee Lee; Jae Ho Kwon; Bong Soo Kyung
Journal:  Indian J Orthop       Date:  2017 Mar-Apr       Impact factor: 1.251

8.  Confirming Proper Button Deployment of Suspensory Fixation During ACL Reconstruction.

Authors:  Daniel F O'Brien; Lilah Fones; Victoria Stoj; Cory Edgar; Katherine Coyner; Robert A Arciero
Journal:  Orthop J Sports Med       Date:  2021-01-19

9.  Bone Tunnel Diameter Measured with CT after Anterior Cruciate Ligament Reconstruction Using Double-Bundle Auto-Hamstring Tendons: Clinical Implications.

Authors:  Soo Jeong Yoon; Young Cheol Yoon; So Young Bae; Joon Ho Wang
Journal:  Korean J Radiol       Date:  2015-10-26       Impact factor: 3.500

10.  Comparative Study after Hamstring Anterior Cruciate Ligament Reconstruction with Endobutton and Rigidfix: A Clinical Trial Study.

Authors:  Hamid Mousavi; Abdellah Maleki; Alireza Nobakht
Journal:  Adv Biomed Res       Date:  2017-11-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.