Literature DB >> 19944433

Long-term (5- to 20-year) patency of the radial artery for coronary bypass grafting.

Paul Achouh1, Redha Boutekadjirt, Daniel Toledano, Nadjib Hammoudi, Jean-Yves Pagny, Pascal Goube, Khaled Ould Isselmou, Bernard Lancelin, Régis Fouquet, Christophe Acar.   

Abstract

OBJECTIVE: The aim of this study was to assess the angiographic results of the radial artery as a coronary bypass conduit at long term (>5 years).
METHODS: Radial artery grafts were controlled in 202 patients at 10.1 years by conventional angiography (n = 79) and computed tomography (n = 123). Clinical or paraclinical evidence of ischemia was noted in 81 patients, whereas 121 patients were asymptomatic. Some 520 conduits were controlled: radial artery (n = 230), left internal thoracic artery (n = 190), right internal thoracic artery (n = 30), and veins (n = 70). Radial arteries were anastomosed to the right coronary (24%), marginal (58%), diagonal (16%), and left anterior descending (<1%) arteries, whereas left internal thoracic arteries were primarily anastomosed to the left anterior descending artery (95%). The mean number of antithrombotic and anti-anginal medications was 1.2 and 1.9 per patient, respectively.
RESULTS: The ejection fraction was slightly decreased compared with its preoperative value (54% +/- 11% vs 57% +/- 9%; P = .009). Nine reoperations were required at 10.5 years for valve replacement (n = 8) and isolated bypass (n = 1). Percutaneous intervention was performed in 48 patients (24%) at 7.6 years on a graft (28%) or a native coronary artery (72%). The 10-year patency of radial artery grafts was 83%, which was lower than the patency of left internal thoracic arteries (95%, P < .001) and similar to the patency of right internal thoracic arteries (87%, P = .66) and veins (81%, P = .50). No medication seemed to influence radial artery graft patency (aspirin: P = .26; calcium blockers: P = .36). All graft patency was lower when clinical or paraclinical evidence of ischemia was present than in asymptomatic cases (83% vs 90% P = .02). The patency of left anterior descending grafts was higher than that of non-left anterior descending grafts (96% vs 82% P < .001).
CONCLUSION: The radial artery-to-coronary bypass conduit provided a low coronary reoperation rate with an excellent patency (83%) up to 20 years postoperatively. 2010 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19944433     DOI: 10.1016/j.jtcvs.2009.09.032

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  11 in total

1.  Use of extended radial artery conduit for complete arterial revascularization.

Authors:  H Ibrahim Özdemir; Mohamed A Soliman Hamad; Joost F ter Woorst; Albert H M van Straten
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-02-27

2.  Twenty-year fate of the radial artery graft.

Authors:  Paul Achouh; Christophe Acar
Journal:  Ann Cardiothorac Surg       Date:  2013-07

Review 3.  Saphenous vein graft vs. radial artery graft searching for the best second coronary artery bypass graft.

Authors:  Hilal Ali Al-Sabti; Adil Al Kindi; Khalid Al-Rasadi; Yajnavalka Banerjee; Khamis Al-Hashmi; Ali Al-Hinai
Journal:  J Saudi Heart Assoc       Date:  2013-10

4.  Reappraisal of a 20-year experience with the radial artery as a conduit for coronary bypass grafting.

Authors:  Paul Achouh; Khaled Ould Isselmou; Redha Boutekadjirt; Cosimo D'Alessandro; Jean-Yves Pagny; Regis Fouquet; Jean-Noël Fabiani; Christophe Acar
Journal:  Eur J Cardiothorac Surg       Date:  2012-01       Impact factor: 4.191

5.  Hypoxia differentially regulates arterial and venous smooth muscle cell proliferation via PDGFR-β and VEGFR-2 expression.

Authors:  Alice Chanakira; Raini Dutta; Richard Charboneau; Roderick Barke; Steven M Santilli; Sabita Roy
Journal:  Am J Physiol Heart Circ Physiol       Date:  2011-12-09       Impact factor: 4.733

6.  Surgical technique for the implantation of tissue engineered vascular grafts and subsequent in vivo monitoring.

Authors:  Maxwell T Koobatian; Carmon Koenigsknecht; Sindhu Row; Stelios Andreadis; Daniel Swartz
Journal:  J Vis Exp       Date:  2015-04-03       Impact factor: 1.355

7.  Successful endothelialization and remodeling of a cell-free small-diameter arterial graft in a large animal model.

Authors:  Maxwell T Koobatian; Sindhu Row; Randall J Smith; Carmon Koenigsknecht; Stelios T Andreadis; Daniel D Swartz
Journal:  Biomaterials       Date:  2015-10-14       Impact factor: 12.479

Review 8.  The Use of Radial Artery for CABG: An Update.

Authors:  Francesco Nappi; Francesca Bellomo; Pierluigi Nappi; Camilla Chello; Adelaide Iervolino; Massimo Chello; Christophe Acar
Journal:  Biomed Res Int       Date:  2021-04-07       Impact factor: 3.411

9.  Coronary artery bypass graft surgery using the radial artery as a secondary conduit improves patient survival.

Authors:  John Lin; Wen Cheng; Lawrence S Czer; Michele A De Robertis; James Mirocha; Andrea Ruzza; Robert M Kass; Ali Khoynezhad; Danny Ramzy; Fardad Esmailian; Alfredo Trento
Journal:  J Am Heart Assoc       Date:  2013-08-22       Impact factor: 5.501

10.  Saphenous graft atherosclerosis as assessed by optical coherence tomography data for stenotic and non-stenotic lesions from the OCTOPUS registry.

Authors:  Grzegorz M Kubiak; Elżbieta Pociask; Wojciech Wańha; Magdalena Dobrolińska; Paweł Gąsior; Grzegorz Smolka; Andrzej Ochała; Zbigniew Gąsior; Wojciech Wojakowski; Tomasz Roleder
Journal:  Postepy Kardiol Interwencyjnej       Date:  2018-06-19       Impact factor: 1.426

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.