Literature DB >> 19941977

Fe-Mn alloys for metallic biodegradable stents: degradation and cell viability studies.

Hendra Hermawan1, Agung Purnama, Dominique Dube, Jacques Couet, Diego Mantovani.   

Abstract

Biodegradable stents have shown their potential to be a valid alternative for the treatment of coronary artery occlusion. This new class of stents requires materials having excellent mechanical properties and controllable degradation behaviour without inducing toxicological problems. The properties of the currently considered gold standard material for stents, stainless steel 316L, were approached by new Fe-Mn alloys. The degradation characteristics of these Fe-Mn alloys were investigated including in vitro cell viability. A specific test bench was used to investigate the degradation in flow conditions simulating those of coronary artery. A water-soluble tetrazolium test method was used to study the effect of the alloy's degradation product to the viability of fibroblast cells. These tests have revealed the corrosion mechanism of the alloys. The degradation products consist of metal hydroxides and calcium/phosphorus layers. The alloys have shown low inhibition to fibroblast cells' metabolic activities. It is concluded that they demonstrate their potential to be developed as degradable metallic biomaterials. Copyright (c) 2009 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19941977     DOI: 10.1016/j.actbio.2009.11.025

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  32 in total

1.  Electrical Interconnects Fabricated From Biodegradable Conductive Polymer Composites.

Authors:  Tao Zhang; Melissa Tsang; Lin Du; Minsoo Kim; Mark G Allen
Journal:  IEEE Trans Compon Packaging Manuf Technol       Date:  2019-03-14

2.  Characterization and in vivo evaluation of a bio-corrodible nitrided iron stent.

Authors:  Qimao Feng; Deyuan Zhang; Chaohua Xin; Xiangdong Liu; Wenjiao Lin; Wanqian Zhang; Sun Chen; Kun Sun
Journal:  J Mater Sci Mater Med       Date:  2012-11-27       Impact factor: 3.896

3.  Long-term surveillance of zinc implant in murine artery: Surprisingly steady biocorrosion rate.

Authors:  Adam J Drelich; Shan Zhao; Roger J Guillory; Jaroslaw W Drelich; Jeremy Goldman
Journal:  Acta Biomater       Date:  2017-05-19       Impact factor: 8.947

4.  In Vitro Cytotoxicity, Adhesion, and Proliferation of Human Vascular Cells Exposed to Zinc.

Authors:  Emily R Shearier; Patrick K Bowen; Weilue He; Adam Drelich; Jaroslaw Drelich; Jeremy Goldman; Feng Zhao
Journal:  ACS Biomater Sci Eng       Date:  2016-03-14

5.  Mechanical properties and in vivo performance of a novel sliding-lock bioabsorbable poly-p-dioxanone stent.

Authors:  Qimao Feng; Wenbo Jiang; Kun Sun; Kang Sun; Sun Chen; Lijiao Zhao; Ke Dai; Ning Ma
Journal:  J Mater Sci Mater Med       Date:  2011-08-06       Impact factor: 3.896

Review 6.  Iron and iron-based alloys for temporary cardiovascular applications.

Authors:  A Francis; Y Yang; S Virtanen; A R Boccaccini
Journal:  J Mater Sci Mater Med       Date:  2015-02-26       Impact factor: 3.896

Review 7.  Progress in manufacturing and processing of degradable Fe-based implants: a review.

Authors:  V P Muhammad Rabeeh; T Hanas
Journal:  Prog Biomater       Date:  2022-05-18

8.  Biphasic responses of human vascular smooth muscle cells to magnesium ion.

Authors:  Jun Ma; Nan Zhao; Donghui Zhu
Journal:  J Biomed Mater Res A       Date:  2015-10-07       Impact factor: 4.396

Review 9.  Biodegradable metals for cardiovascular stent application: interests and new opportunities.

Authors:  Maryam Moravej; Diego Mantovani
Journal:  Int J Mol Sci       Date:  2011-06-29       Impact factor: 5.923

Review 10.  Recent Progress on Bioresorbable Passive Electronic Devices and Systems.

Authors:  Zhihuan Wei; Zhongying Xue; Qinglei Guo
Journal:  Micromachines (Basel)       Date:  2021-05-22       Impact factor: 2.891

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.