Literature DB >> 19937778

Impact of rapid ventricular pacing during percutaneous balloon aortic valvuloplasty in patients with critical aortic stenosis: should we be using it?

Christian Witzke1, Creighton W Don, Roberto J Cubeddu, Jesus Herrero-Garibi, Eugene Pomerantsev, Angel Caldera, David McCarty, Ignacio Inglessis, Igor F Palacios.   

Abstract

BACKGROUND: Rapid ventricular pacing (RP) during percutaneous balloon aortic valvuloplasty (BAV) facilitates balloon positioning by preventing the "watermelon seeding" effect during balloon inflation. The clinical consequences of RP BAV have never been compared with standard BAV in which rapid pacing in not used. We evaluated the immediate results and in-hospital adverse events of patients with severe aortic stenosis (AS) undergoing BAV with and without RP.
METHODS: This is a retrospective study of patients with severe AS undergoing retrograde BAV. Patients who underwent BAV with RP were compared to those who did not receive RP during BAV. Procedural outcomes, complications, and in-hospital adverse events were compared between both groups. Stratified analyses were performed to evaluate RP in pre-specified subsets for confounding and effect modification.
RESULTS: Between January 2005 and December 2008, 111 consecutive patients underwent retrograde BAV at Massachusetts General Hospital. Sixty-seven patients underwent BAV with RP. Nearly 90% of patients were NYHA class III or IV and the mean AVA was 0.64 cm(2). Baseline characteristics and balloon sizes were similar in the two groups. The average post-BAV AVA was smaller in the RP group compared to the no-RP group (0.87 v. 1.02 cm(2), p = 0.02). Pre and post-cardiac output, in-hospital mortality, myocardial infarction, stroke, frequency of cardiopulmonary arrest, vasopressor use, and major complications were similar in the two groups.
CONCLUSIONS: 1) RP allows precise balloon placement during BAV. 2) RP BAV is associated with lower post-BAV AVA. 3) RP BAV may be safely performed in patients with high-risk cardiac features.

Entities:  

Mesh:

Year:  2010        PMID: 19937778     DOI: 10.1002/ccd.22289

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  16 in total

1.  Dynamic device properties of pulse contour cardiac output during transcatheter aortic valve implantation.

Authors:  Martin Petzoldt; Carsten Riedel; Jan Braeunig; Sebastian Haas; Matthias S Goepfert; Hendrik Treede; Stephan Baldus; Alwin E Goetz; Daniel A Reuter
Journal:  J Clin Monit Comput       Date:  2014-10-30       Impact factor: 2.502

Review 2.  Mechanical circulatory support in patients with severe aortic stenosis and left ventricular dysfunction undergoing percutaneous coronary intervention.

Authors:  Mohamad Alkhouli; Ahmed Al Mustafa; Zakeih Chaker; Fahad Alqahtani; Sami Aljohani; David R Holmes
Journal:  J Card Surg       Date:  2017-03-07       Impact factor: 1.620

3.  Impact of rapid ventricular pacing during TAVI on microvascular tissue perfusion.

Authors:  Anna Selle; Hans R Figulla; Markus Ferrari; Wilma Rademacher; Bjoern Goebel; Ali Hamadanchi; Marcus Franz; Andrea Schlueter; Thomas Lehmann; Alexander Lauten
Journal:  Clin Res Cardiol       Date:  2014-06-05       Impact factor: 5.460

4.  Effect of transcatheter aortic valve implantation on intraoperative left ventricular end-diastolic pressure.

Authors:  Kosaku Toyota; Takashi Ota; Katsutoshi Nagamine; Yasuhiro Koide; Takeshi Nomura; Futoshi Yamanaka; Koki Shishido; Masashi Tanaka; Shigeru Saito
Journal:  J Anesth       Date:  2016-08-11       Impact factor: 2.078

5.  A longer total duration of rapid ventricular pacing does not increase the risk of postprocedural myocardial injury in patients who undergo transcatheter aortic valve implantation.

Authors:  Kenta Okitsu; Takeshi Iritakenishi; Tatsuyuki Imada; Mitsuo Iwasaki; Sho Carl Shibata; Yuji Fujino
Journal:  Heart Vessels       Date:  2017-03-20       Impact factor: 2.037

6.  The safety and feasibility of retrograde balloon aortic valvuloplasty using the INOUE-BALLOON with severe aortic stenosis.

Authors:  Naoko Yuzawa-Tsukada; Yusuke Kashiwagi; Akira Nonoue; Goki Uno; Shinya Fujii; Akimichi Murakami; Kazuo Ogawa; Makoto Kawai; Makoto Muto; Michihiro Yoshimura; Takashi Miyamoto
Journal:  Heart Vessels       Date:  2022-07-16       Impact factor: 1.814

7.  Patients with small left ventricular size undergoing balloon aortic valvuloplasty have worse intraprocedural outcomes.

Authors:  Creighton Don; Pritha P Gupta; Christian Witzke; Manoj Kesarwani; Roberto J Cubeddu; Ignacio Inglessis; Igor F Palacios
Journal:  Catheter Cardiovasc Interv       Date:  2012-08-23       Impact factor: 2.692

Review 8.  Myocardial injury associated with transcatheter aortic valve implantation (TAVI).

Authors:  Won-Keun Kim; Christoph Liebetrau; Arnaud van Linden; Johannes Blumenstein; Luise Gaede; Christian W Hamm; Thomas Walther; Helge Möllmann
Journal:  Clin Res Cardiol       Date:  2015-12-15       Impact factor: 5.460

9.  Long-term results of percutaneous balloon valvuloplasty of congenital aortic stenosis in adolescents and young adults.

Authors:  Neeraj Awasthy; Ria Garg; S Radhakrishnan; Savitri Shrivastava
Journal:  Indian Heart J       Date:  2016-03-30

10.  Aortic Valve Predilatation with a Small Balloon, without Rapid Pacing, prior to Transfemoral Transcatheter Aortic Valve Replacement.

Authors:  Anupama Shivaraju; Christian Thilo; Neal Sawlani; Ilka Ott; Heribert Schunkert; Wolfgang von Scheidt; Adnan Kastrati; Albert Markus Kasel
Journal:  Biomed Res Int       Date:  2018-04-30       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.