Literature DB >> 27514383

Effect of transcatheter aortic valve implantation on intraoperative left ventricular end-diastolic pressure.

Kosaku Toyota1, Takashi Ota2, Katsutoshi Nagamine2, Yasuhiro Koide2, Takeshi Nomura3, Futoshi Yamanaka4, Koki Shishido4, Masashi Tanaka5, Shigeru Saito4.   

Abstract

Transcatheter aortic valve implantation (TAVI) for patients with aortic stenosis is a less invasive alternative to surgical aortic valve replacement. Despite this, careful anesthetic management, especially strict control of blood pressure and fluid management, is necessary. During TAVI, normalization of left ventricular afterload due to aortic balloon valvuloplasty and prosthetic valve deployment is expected to result in rapid improvement of systolic function and consequent improvement in diastolic function. However, the early effect of TAVI on left ventricular diastolic function is less clear. We hypothesized that TAVI induces a rapid decrease in left ventricular end-diastolic pressure (LVEDP) after valve deployment. This retrospective observational study included 71 patients who had undergone TAVI using the transfemoral approach with a balloon-expandable valve under general anesthesia. Intraoperative LVEDP was measured using an intracardiac catheter. The severity of residual aortic regurgitation (AR) was assessed using the Sellers criteria. The mean (SD) LVEDP was 17.8 (5.3) mmHg just before TAVI and increased significantly to 27.3 (8.2) mmHg immediately after prosthetic valve deployment (p < 0.0001). The change in LVEDP was 8.7 (8.6) mmHg in patients with low residual AR (Sellers ≤1) and 11.0 (7.1) mmHg in those with high residual AR (Sellers ≥2); however, this difference was not significant. No correlation was found between the LVEDP change and intraoperative fluid balance. In conclusion, LVEDP increased significantly in the early period after valve deployment during TAVI, regardless of residual AR severity. It was suggested that the tolerability of fluid load could be reduced at that time.

Entities:  

Keywords:  Aortic regurgitation; LV filling physiology; Left ventricular end-diastolic pressure; TAVI complications

Mesh:

Year:  2016        PMID: 27514383     DOI: 10.1007/s00540-016-2229-7

Source DB:  PubMed          Journal:  J Anesth        ISSN: 0913-8668            Impact factor:   2.078


  17 in total

1.  Transcatheter aortic valve implantation: early results of the FRANCE (FRench Aortic National CoreValve and Edwards) registry.

Authors:  Hélène Eltchaninoff; Alain Prat; Martine Gilard; Alain Leguerrier; Didier Blanchard; Gérard Fournial; Bernard Iung; Patrick Donzeau-Gouge; Christophe Tribouilloy; Jean-Louis Debrux; Alain Pavie; Pascal Gueret
Journal:  Eur Heart J       Date:  2010-09-15       Impact factor: 29.983

2.  Progress and current status of percutaneous aortic valve replacement: results of three device generations of the CoreValve Revalving system.

Authors:  Eberhard Grube; Lutz Buellesfeld; Ralf Mueller; Barthel Sauren; Bernfried Zickmann; Dinesh Nair; Harald Beucher; Thomas Felderhoff; Stein Iversen; Ulrich Gerckens
Journal:  Circ Cardiovasc Interv       Date:  2008-12       Impact factor: 6.546

Review 3.  Transcatheter aortic valve implantation: review of the nature, management, and avoidance of procedural complications.

Authors:  Jean-Bernard Masson; Jan Kovac; Gerhard Schuler; Jian Ye; Anson Cheung; Samir Kapadia; Murat E Tuzcu; Susheel Kodali; Martin B Leon; John G Webb
Journal:  JACC Cardiovasc Interv       Date:  2009-09       Impact factor: 11.195

4.  Recovery of left ventricular mechanics after transcatheter aortic valve implantation: effects of baseline ventricular function and postprocedural aortic regurgitation.

Authors:  Frédéric Poulin; Shemy Carasso; Eric M Horlick; Harry Rakowski; Ki-Dong Lim; Heather Finn; Christopher M Feindel; Matthias Greutmann; Mark D Osten; Robert J Cusimano; Anna Woo
Journal:  J Am Soc Echocardiogr       Date:  2014-08-07       Impact factor: 5.251

5.  Impact of rapid ventricular pacing during TAVI on microvascular tissue perfusion.

Authors:  Anna Selle; Hans R Figulla; Markus Ferrari; Wilma Rademacher; Bjoern Goebel; Ali Hamadanchi; Marcus Franz; Andrea Schlueter; Thomas Lehmann; Alexander Lauten
Journal:  Clin Res Cardiol       Date:  2014-06-05       Impact factor: 5.460

6.  Acute left ventricle diastolic function improvement after transcatheter aortic valve implantation.

Authors:  Alexandra Gonçalves; Pedro Marcos-Alberca; Carlos Almeria; Gisela Feltes; Enrique Rodríguez; Rosa Ana Hernández-Antolín; Eulogio Garcia; Luis Maroto; Cristina Fernandez Perez; José C Silva Cardoso; Carlos Macaya; José Luis Zamorano
Journal:  Eur J Echocardiogr       Date:  2011-08-23

7.  Transcatheter aortic valve implantation: first results from a multi-centre real-world registry.

Authors:  Ralf Zahn; Ulrich Gerckens; Eberhard Grube; Axel Linke; Horst Sievert; Holger Eggebrecht; Rainer Hambrecht; Stefan Sack; Karl Eugen Hauptmann; Gert Richardt; Hans-Reiner Figulla; Jochen Senges
Journal:  Eur Heart J       Date:  2010-09-23       Impact factor: 29.983

8.  Registry of transcatheter aortic-valve implantation in high-risk patients.

Authors:  Martine Gilard; Hélène Eltchaninoff; Bernard Iung; Patrick Donzeau-Gouge; Karine Chevreul; Jean Fajadet; Pascal Leprince; Alain Leguerrier; Michel Lievre; Alain Prat; Emmanuel Teiger; Thierry Lefevre; Dominique Himbert; Didier Tchetche; Didier Carrié; Bernard Albat; Alain Cribier; Gilles Rioufol; Arnaud Sudre; Didier Blanchard; Frederic Collet; Pierre Dos Santos; Nicolas Meneveau; Ashok Tirouvanziam; Christophe Caussin; Philippe Guyon; Jacques Boschat; Herve Le Breton; Frederic Collart; Remi Houel; Stephane Delpine; Geraud Souteyrand; Xavier Favereau; Patrick Ohlmann; Vincent Doisy; Gilles Grollier; Antoine Gommeaux; Jean-Philippe Claudel; Francois Bourlon; Bernard Bertrand; Eric Van Belle; Marc Laskar
Journal:  N Engl J Med       Date:  2012-05-03       Impact factor: 91.245

Review 9.  Outcomes and safety of percutaneous aortic valve replacement.

Authors:  Alan Zajarias; Alain G Cribier
Journal:  J Am Coll Cardiol       Date:  2009-05-19       Impact factor: 24.094

Review 10.  Technique of transcatheter aortic valve implantation with the Edwards-Sapien heart valve using the transfemoral approach.

Authors:  Alain Cribier; Pierre-Yves Litzler; Helene Eltchaninoff; Matthieu Godin; Christophe Tron; Fabrice Bauer; Jean-Paul Bessou
Journal:  Herz       Date:  2009-08       Impact factor: 1.443

View more
  2 in total

1.  Acute haemodynamic impact of transcatheter aortic valve implantation in patients with severe aortic stenosis.

Authors:  Francesca Graziani; Pio Cialdella; Rosa Lillo; Gabriella Locorotondo; Lorenzo Genuardi; Gessica Ingrasciotta; Stefano Cangemi; Marialisa Nesta; Piergiorgio Bruno; Cristina Aurigemma; Enrico Romagnoli; Michele Calabrese; Nicole Giambusso; Antonella Lombardo; Francesco Burzotta; Carlo Trani
Journal:  ESC Heart Fail       Date:  2022-03-29

2.  Early hemodynamic changes after transcatheter aortic valve implantation in patients with severe aortic stenosis measured by invasive pressure volume loop analysis.

Authors:  Philipp Christian Seppelt; Roberta De Rosa; Silvia Mas-Peiro; Andreas Michael Zeiher; Mariuca Vasa-Nicotera
Journal:  Cardiovasc Interv Ther       Date:  2020-12-12
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.