Literature DB >> 1993622

Quantitative assessment of interstitial implants.

C B Saw1, N Suntharalingam.   

Abstract

Quantitative assessment of interstitial implants is proposed using volume versus dose curves and four well-defined dosimetric parameters. The volume versus dose curves, both differential and cumulative, provide quantitative data on the volumes of tissues irradiated to different doses. They also offer a qualitative assessment of the variations in dose delivery. The dose nonuniformity ratio (DNR) quantitatively determines the degree of dose nonuniformity specific to the implant configuration. The dose rate at which the DNR shows a minimum value, if selected as the treatment dose rate, gives an optimized dose distribution. The three volumetric irradiation indices are formulated with respect to a well-defined target volume. They offer quantitative data on the extent to which the implant delivers the prescribed dose to the target volume. These dosimetric parameters determine the degree of coverage of the target volume, dose homogeneity within the target volume, and irradiation of tissues outside the target volume. The method of quantitative assessment is demonstrated using, as examples, an ideal Ir-192 double-plane implant and an actual clinical Ir-192 double-plane breast implant.

Mesh:

Year:  1991        PMID: 1993622     DOI: 10.1016/0360-3016(91)90149-x

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  26 in total

1.  Quality assessment of interstitial implants in high- dose- rate brachytherapy after lumpectomy in patients of early stage breast cancer.

Authors:  Samrat Dutta; Suresh C Sharma; Rajinder Singh; Rakesh Kapoor; Arun S Oinam; Anoop Bhardwaj; Pradeep Goswami
Journal:  Indian J Surg Oncol       Date:  2011-03-24

2.  Surgical resection followed by brachytherapy for malignancies involving the base of the skull.

Authors:  E Cano; I Janecka; C Saw; C Rassekh
Journal:  Skull Base Surg       Date:  1993

Review 3.  Quality of life of oropharyngeal cancer patients treated with brachytherapy.

Authors:  David N Teguh; Peter C Levendag; Inger-Karine Kolkman-Deurloo; Peter van Rooij; Paul I M Schmitz
Journal:  Curr Oncol Rep       Date:  2009-03       Impact factor: 5.075

4.  Dosimetric analysis and comparison of IMRT and HDR brachytherapy in treatment of localized prostate cancer.

Authors:  V Murali; P G G Kurup; P Mahadev; S Mahalakshmi
Journal:  J Med Phys       Date:  2010-04

5.  An audit of high dose-rate prostate brachytherapy treatment planning at six Swedish clinics.

Authors:  Frida Dohlmar; Sakarias Johansson; Torbjörn Larsson; Michael Sandborg; Åsa Carlsson Tedgren
Journal:  J Contemp Brachytherapy       Date:  2021-02-18

6.  Accuracy and dosimetric parameters comparison of 3D-printed non-coplanar template-assisted computed tomography-guided iodine-125 seed ablative brachytherapy in pelvic lateral recurrence of gynecological carcinomas.

Authors:  Ang Qu; Ping Jiang; Shuhua Wei; Yuliang Jiang; Zhe Ji; Haitao Sun; Weiyan Li; Yuxia Shao; Jinghong Fan; Junjie Wang
Journal:  J Contemp Brachytherapy       Date:  2021-02-18

7.  Dosimetric comparison of computed tomography-guided iodine-125 seed implantation assisted with and without three-dimensional printing non-coplanar template in locally recurrent rectal cancer: a propensity score matching study.

Authors:  Lu Wang; Hao Wang; Yuliang Jiang; Zhe Ji; Fuxin Guo; Ping Jiang; Bin Qiu; Haitao Sun; Jinghong Fan; Weiyan Li; Junjie Wang
Journal:  J Contemp Brachytherapy       Date:  2021-02-18

8.  Interstitial brachytherapy for bladder cancer with the aid of laparoscopy.

Authors:  Annemieke Nap-van Klinken; Saskia J E A Bus; Theodorus G Janssen; Marion P R Van Gellekom; Geert Smits; Elzbieta Van der Steen-Banasik
Journal:  J Contemp Brachytherapy       Date:  2014-09-23

9.  Qualitative dosimetric and radiobiological evaluation of high - dose - rate interstitial brachytherapy implants.

Authors:  Than S Kehwar; Syed F Akber; Kamlesh Passi
Journal:  Int J Med Sci       Date:  2008-02-19       Impact factor: 3.738

10.  Analysis on the accuracy of CT-guided radioactive I-125 seed implantation with 3D printing template assistance in the treatment of thoracic malignant tumors.

Authors:  Zhe Ji; Haitao Sun; Yuliang Jiang; Yi Chen; Fuxin Guo; Jinghong Fan; Junjie Wang
Journal:  J Radiat Res       Date:  2021-09-13       Impact factor: 2.724

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.