OBJECTIVE: The purpose of this study was to compare apparent diffusion coefficients, metabolic ratios, and vascularity values within histologically defined prostate tumors with those in nontumor tissue to determine which functional parameter or combination of parameters is best for differentiating tumor from nontumor tissue. SUBJECTS AND METHODS: Twenty patients due for prostatectomy underwent endorectal MRI at 1.5 T. Transverse T2-weighted, diffusion-weighted, 2D chemical shift, and dynamic contrast-enhanced images were acquired. After prostatectomy, the gland was sectioned transversely. Fresh slices and stained whole-mount sections with histologically defined tumor outlines were photographed. The tumor outlines were mapped onto images, and the apparent diffusion coefficient (ADC), choline-to-citrate (Cho/cit) ratio, and vascularity of the histologically defined tumor, normal peripheral zone, and central gland were quantitatively measured. Area under the receiver operating characteristics (ROC) curve (A(z)) was used to determine the sensitivity and specificity of parameter combinations in cancer detection. RESULTS: In tumor regions larger than 1 cm(2), the Cho/cit ratio was higher in tumor than in nontumor tissue (p < 0.001), in the peripheral zone alone (p = 0.007), and in the central gland alone (p = 0.005). ADC was lower and tumor vascularity greater in tumor than in nontumor tissue (ADC, p = 0.003; initial area under the gadolinium plasma concentration-time curve [initial gadolinium AUC], p = 0.012; forward rate constant [K(trans)], p = 0.011; return rate constant [k(ep)], p = 0.036). No single parameter had a significantly greater A(z) (ADC, 0.71; Cho/cit ratio, 0.79; initial gadolinium AUC, 0.60; K(trans), 0.62; k(ep), 0.65). Pairs of parameters, however, did increase A(z): ADC and initial gadolinium AUC (A(z) = 0.94) versus ADC (p = 0.001) and initial gadolinium AUC (p < 0.001); ADC and Cho/cit ratio (A(z) = 0.94) versus ADC (p = 0.001) and Cho/cit ratio (not significant); and Cho/cit ratio and initial gadolinium AUC (A(z) = 0.88) versus Cho/cit ratio (not significant) and initial gadolinium AUC (p < 0.001). All three functional techniques together had an A(z) of 0.95, showing no further improvement. CONCLUSION: The combination of two functional parameters is associated with significant improvement in prostate cancer detection over use of any parameter alone. Use of a third parameter does not increase the rate of detection.
OBJECTIVE: The purpose of this study was to compare apparent diffusion coefficients, metabolic ratios, and vascularity values within histologically defined prostate tumors with those in nontumor tissue to determine which functional parameter or combination of parameters is best for differentiating tumor from nontumor tissue. SUBJECTS AND METHODS: Twenty patients due for prostatectomy underwent endorectal MRI at 1.5 T. Transverse T2-weighted, diffusion-weighted, 2D chemical shift, and dynamic contrast-enhanced images were acquired. After prostatectomy, the gland was sectioned transversely. Fresh slices and stained whole-mount sections with histologically defined tumor outlines were photographed. The tumor outlines were mapped onto images, and the apparent diffusion coefficient (ADC), choline-to-citrate (Cho/cit) ratio, and vascularity of the histologically defined tumor, normal peripheral zone, and central gland were quantitatively measured. Area under the receiver operating characteristics (ROC) curve (A(z)) was used to determine the sensitivity and specificity of parameter combinations in cancer detection. RESULTS: In tumor regions larger than 1 cm(2), the Cho/cit ratio was higher in tumor than in nontumor tissue (p < 0.001), in the peripheral zone alone (p = 0.007), and in the central gland alone (p = 0.005). ADC was lower and tumor vascularity greater in tumor than in nontumor tissue (ADC, p = 0.003; initial area under the gadolinium plasma concentration-time curve [initial gadolinium AUC], p = 0.012; forward rate constant [K(trans)], p = 0.011; return rate constant [k(ep)], p = 0.036). No single parameter had a significantly greater A(z) (ADC, 0.71; Cho/cit ratio, 0.79; initial gadolinium AUC, 0.60; K(trans), 0.62; k(ep), 0.65). Pairs of parameters, however, did increase A(z): ADC and initial gadolinium AUC (A(z) = 0.94) versus ADC (p = 0.001) and initial gadolinium AUC (p < 0.001); ADC and Cho/cit ratio (A(z) = 0.94) versus ADC (p = 0.001) and Cho/cit ratio (not significant); and Cho/cit ratio and initial gadolinium AUC (A(z) = 0.88) versus Cho/cit ratio (not significant) and initial gadolinium AUC (p < 0.001). All three functional techniques together had an A(z) of 0.95, showing no further improvement. CONCLUSION: The combination of two functional parameters is associated with significant improvement in prostate cancer detection over use of any parameter alone. Use of a third parameter does not increase the rate of detection.
Authors: B Nicolas Bloch; Elizabeth M Genega; Daniel N Costa; Ivan Pedrosa; Martin P Smith; Herbert Y Kressel; Long Ngo; Martin G Sanda; William C Dewolf; Neil M Rofsky Journal: Eur Radiol Date: 2012-06-03 Impact factor: 5.315
Authors: Ashwin N Sridhar; Archie Hughes-Hallett; Erik K Mayer; Philip J Pratt; Philip J Edwards; Guang-Zhong Yang; Ara W Darzi; Justin A Vale Journal: Nat Rev Urol Date: 2013-06-18 Impact factor: 14.432
Authors: Baris Turkbey; Haresh Mani; Vijay Shah; Ardeshir R Rastinehad; Marcelino Bernardo; Thomas Pohida; Yuxi Pang; Dagane Daar; Compton Benjamin; Yolanda L McKinney; Hari Trivedi; Celene Chua; Gennady Bratslavsky; Joanna H Shih; W Marston Linehan; Maria J Merino; Peter L Choyke; Peter A Pinto Journal: J Urol Date: 2011-09-25 Impact factor: 7.450
Authors: Barış Türkbey; Marcelino Bernardo; Maria J Merino; Bradford J Wood; Peter A Pinto; Peter L Choyke Journal: Diagn Interv Radiol Date: 2011-09-16 Impact factor: 2.630
Authors: Baris Turkbey; Vijay P Shah; Yuxi Pang; Marcelino Bernardo; Sheng Xu; Jochen Kruecker; Julia Locklin; Angelo A Baccala; Ardeshir R Rastinehad; Maria J Merino; Joanna H Shih; Bradford J Wood; Peter A Pinto; Peter L Choyke Journal: Radiology Date: 2010-12-21 Impact factor: 11.105
Authors: Berrend G Muller; Jurgen J Fütterer; Rajan T Gupta; Aaron Katz; Alexander Kirkham; John Kurhanewicz; Judd W Moul; Peter A Pinto; Ardeshir R Rastinehad; Cary Robertson; Jean de la Rosette; Rafael Sanchez-Salas; J Stephen Jones; Osamu Ukimura; Sadhna Verma; Hessel Wijkstra; Michael Marberger Journal: BJU Int Date: 2013-11-13 Impact factor: 5.588
Authors: Kirema Garcia-Reyes; Niccolò M Passoni; Mark L Palmeri; Christopher R Kauffman; Kingshuk Roy Choudhury; Thomas J Polascik; Rajan T Gupta Journal: Abdom Imaging Date: 2015-01