Literature DB >> 19927268

Incidence of conjunctival exposure following drainage device implantation in patients with glaucoma.

William C Stewart1, Caroline J Kristoffersen, Christina M Demos, Mario G Fsadni, Jeanette A Stewart.   

Abstract

PURPOSE: To evaluate prior studies including a glaucoma drainage device and to describe the timing and incidence of conjunctival exposure. A meta-analysis of previously published articles.
METHODS: Articles included were prospective, single cohort, or comparative parallel design, with a mean treatment period of at least 3 months and at least 30 patients per treatment arm. We limited our analysis to studies that evaluated the most common devices, including Ahmed, Baerveldt, and Molteno.
RESULTS: We included 38 studies containing 45 treatment arms (16 Ahmed, 12 Baerveldt, and 17 Molteno). These studies included 3,105 patients and 3,255 eyes with an average follow-up of 26.1+/-3.3 months. The overall incidence of exposure was 2.0+/-2.6% (n=64) of eyes with an average exposure/month of 0.09+/-0.14%. There was no significant correlation between study length and incidence of exposure (p=0.11), although multivariate regression analysis identified length of follow-up as a risk factor for exposure (p=0.001). Among individual drainage devices, there was no significant difference in the incidence of exposure (p=0.22) or percent exposure per month (p=0.18). In addition, no difference existed in the incidence of exposure between sizes for the Baerveldt 250, 350 or 500 mm (p=0.7), number of plates for the Molteno Single or Double (p=0.3), nor between the composition of the Ahmed Silicone or Polypropylene (p=0.7).
CONCLUSIONS: This study suggests that tube exposure of glaucoma implants is unusual and the incidence does not differ between the Ahmed, Baerveldt, and Molteno implants. However, exposure appears to occur at any time within the first 5 years following implantation.

Entities:  

Mesh:

Year:  2010        PMID: 19927268     DOI: 10.1177/112067211002000117

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  14 in total

1.  Baerveldt® glaucoma implant surgery with the double scleral flap technique to prevent Hoffman elbow exposure.

Authors:  Naoki Tojo; Tomoko Ueda-Consolvo; Shuichiro Yanagisawa; Atsushi Hayashi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-07-22       Impact factor: 3.117

2.  Glaucoma drainage devices: risk of exposure and infection.

Authors:  Joshua D Levinson; Annette L Giangiacomo; Allen D Beck; Paul B Pruett; Hillary M Superak; Michael J Lynn; Anastasios P Costarides
Journal:  Am J Ophthalmol       Date:  2015-05-30       Impact factor: 5.258

3.  Tube Exposure Repair.

Authors:  Stirbu Oana; Jorge Vila
Journal:  J Curr Glaucoma Pract       Date:  2012-10-16

4.  Outcomes of the Shunt Tube Exposure Prevention Study: A Randomized Clinical Trial.

Authors:  Hosam Sheha; Celso Tello; Lama A Al-Aswad; Mohamed S Sayed; Richard K Lee
Journal:  Ophthalmol Glaucoma       Date:  2019-08-16

5.  Tube shunt coverage with gamma-irradiated cornea allograft (VisionGraft).

Authors:  Feyzahan Ekici; Marlene R Moster; Victor Cvintal; Wanda D Hu; Michael Waisbourd
Journal:  Clin Ophthalmol       Date:  2015-05-04

6.  Partial thickness corneal tissue as a patch graft material for prevention of glaucoma drainage device exposure.

Authors:  Oriel Spierer; Michael Waisbourd; Yitzhak Golan; Hadas Newman; Rony Rachmiel
Journal:  BMC Ophthalmol       Date:  2016-02-27       Impact factor: 2.209

Review 7.  Ahmed glaucoma valve implant: surgical technique and complications.

Authors:  Ivano Riva; Gloria Roberti; Francesco Oddone; Anastasios Gp Konstas; Luciano Quaranta
Journal:  Clin Ophthalmol       Date:  2017-02-17

8.  Short-Term Outcomes of KeraSys Patch Graft for Glaucoma Drainage Devices: A Case Series.

Authors:  Kundandeep S Nagi; Ricardo J Cumba; Nicholas P Bell; Lauren S Blieden; Alice Z Chuang; Kimberly A Mankiewicz; Donna Nguyen; Robert M Feldman
Journal:  J Ophthalmol       Date:  2013-03-17       Impact factor: 1.909

9.  Risk factors for tube exposure as a late complication of glaucoma drainage implant surgery.

Authors:  Meenakshi Chaku; Peter A Netland; Kyoko Ishida; Douglas J Rhee
Journal:  Clin Ophthalmol       Date:  2016-03-30

10.  Repair of Tube Erosion by Modifying the Tube Extender.

Authors:  Wendy W Liu; Astrid Werner; Teresa C Chen
Journal:  J Glaucoma       Date:  2020-07       Impact factor: 2.290

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.