Literature DB >> 19927048

Comparison of differing sedation practice for upper endoscopic ultrasound using expert observational analysis of the procedural sedation.

John Michael Trummel1, Stephen D Surgenor, Joseph P Cravero, Stuart R Gordon, George T Blike.   

Abstract

AIM: To compare the quality between 2 commonly used sedation practices for upper endoscopic ultrasound (EUS) by using expert observational analysis of the sedation practice.
METHODS: After institutional review board approval, 50 adults undergoing EUS had videotape observation of the procedural sedation: 25 received benzodiazepine/opiate administered by the endoscopy team as per the standard protocol at our institution, and 25 received propofol administered by a dedicated anesthesiologist. Quantitative analysis of the video was performed using the Dartmouth Operative Conditions Scale (DOCS). The DOCS is a tool previously developed to quantify the adequacy of procedural sedation through an objective measurement of the patient state during the sedation process. In this study, the DOCS was used in a novel way to compare the quality of sedation provided by different sedation protocols. Data were collected on patient demographics, patient and provider satisfaction, efficiency, side effects, and safety measures.
RESULTS: Videotape analysis using the DOCS revealed that 52% (13/25) of the standard group exhibited an uncontrolled patient state (significant undersedation and/or oversedation) on 1 or more occasion during their EUS procedure compared with 28% (7/25) of the propofol group. Patients in the standard group spent 7.1% of the procedure in an uncontrolled patient state, whereas patients in the propofol group experienced an uncontrolled state approximately 1.0% of the procedure time. Overall efficiency as measured by time in both the procedure room and in recovery was superior in the propofol group. These patients spent 12 less minutes on average in the procedure room and were ready for discharge in about half the time (56 minutes versus 109 minutes). The propofol group experienced significantly less in-hospital and at-home nausea and vomiting and felt back to baseline status more quickly. Finally, patient satisfaction was improved in the propofol group: 60% felt the procedure was better than anticipated versus 21% in the standard group.
CONCLUSIONS: Expert videotape analysis of the patient state during procedural sedation allows direct comparison of sedation methodologies using small numbers of patients. In our institution, endoscopist-directed sedation using a midazolam/narcotic combination for EUS proved inferior to sedation using propofol given by an anesthesiologist. Specifically, a midazolam/narcotic combination provided less effective intraprocedural conditions, was less efficient both before and after the procedure, and was less satisfactory to patients as compared with propofol. Results of this type of analysis can be used to drive appropriate system redesign and improve patient care.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19927048     DOI: 10.1097/PTS.0b013e3181b53f80

Source DB:  PubMed          Journal:  J Patient Saf        ISSN: 1549-8417            Impact factor:   2.844


  6 in total

1.  Redefining quality in endoscopic sedation.

Authors:  Lawrence B Cohen
Journal:  Dig Dis Sci       Date:  2010-09       Impact factor: 3.199

2.  Sedation, analgesia, and cardiorespiratory function in colonoscopy using midazolam combined with fentanyl or propofol.

Authors:  Fen Wang; Shou-Rong Shen; Ding-Hua Xiao; Can-Xia Xu; Wu-Liang Tang
Journal:  Int J Colorectal Dis       Date:  2011-03-16       Impact factor: 2.571

3.  Predicting what can go wrong at endoscopic ultrasound: a large series experience.

Authors:  Evangelos Kalaitzakis; Konstantinos Varytimiadis; John Meenan
Journal:  Frontline Gastroenterol       Date:  2010-11-20

Review 4.  Diagnostic endoscopic ultrasonography: assessment of safety and prevention of complications.

Authors:  Christian Jenssen; Maria Victoria Alvarez-Sánchez; Bertrand Napoléon; Siegbert Faiss
Journal:  World J Gastroenterol       Date:  2012-09-14       Impact factor: 5.742

5.  Recent advances in using propofol by non-anesthesiologists.

Authors:  Gang Tan; Michael G Irwin
Journal:  F1000 Med Rep       Date:  2010-11-11

6.  Delayed flumazenil injection after endoscopic sedation increases patient satisfaction compared with immediate flumazenil injection.

Authors:  Hyun Jung Chung; Byoung Wook Bang; Hyung Gil Kim; Kye Sook Kwon; Yong Woon Shin; Seok Jeong; Don Haeng Lee; Shin Goo Park
Journal:  Gut Liver       Date:  2013-08-14       Impact factor: 4.519

  6 in total