Investigation of uncertainties in image registration of cone beam CT to CT on an image-guided radiotherapy system.

J R Sykes1, D S Brettle, D R Magee, D I Thwaites.   

Abstract

Methods of measuring uncertainties in rigid body image registration of fan beam computed tomography (FBCT) to cone beam CT (CBCT) have been developed for automatic image registration algorithms in a commercial image guidance system (Synergy, Elekta, UK). The relationships between image registration uncertainty and both imaging dose and image resolution have been investigated with an anthropomorphic skull phantom and further measurements performed with patient images of the head. A new metric of target registration error is proposed. The metric calculates the mean distance traversed by a set of equi-spaced points on the surface of a 5 cm sphere, centred at the isocentre when transformed by the residual error of registration. Studies aimed at giving practical guidance on the use of the Synergy automated image registration, including choice of algorithm and use of the Clipbox are reported. The chamfer-matching algorithm was found to be highly robust to the increased noise induced by low-dose acquisitions. This would allow the imaging dose to be reduced from the current clinical norm of 2 mGy to 0.2 mGy without a clinically significant loss of accuracy. A study of the effect of FBCT slice thickness/spacing and CBCT voxel size showed that 2.5 mm and 1 mm, respectively, gave acceptable image registration performance. Registration failures were highly infrequent if the misalignment was typical of normal clinical set-up errors and these were easily identified. The standard deviation of translational registration errors, measured with patient images, was 0.5 mm on the surface of a 5 cm sphere centred on the treatment centre. The chamfer algorithm is suitable for routine clinical use with minimal need for close inspection of image misalignment.

Entities:  

Mesh:

Year:  2009        PMID: 19926913     DOI: 10.1088/0031-9155/54/24/002

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  8 in total

1.  Proton dose calculation on scatter-corrected CBCT image: Feasibility study for adaptive proton therapy.

Authors:  Yang-Kyun Park; Gregory C Sharp; Justin Phillips; Brian A Winey
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

2.  Estimation of delivered dose in radiotherapy: the influence of registration uncertainty.

Authors:  Petter Risholm; James Balter; William M Wells
Journal:  Med Image Comput Comput Assist Interv       Date:  2011

3.  Evaluation of inter-fraction and intra-fraction errors during volumetric modulated arc therapy in nasopharyngeal carcinoma patients.

Authors:  Wen-Jing Yin; Ying Sun; Feng Chi; Jian-Lan Fang; Rui Guo; Xiao-Li Yu; Yan-Ping Mao; Zhen-Yu Qi; Ying Guo; Meng-Zhong Liu; Jun Ma
Journal:  Radiat Oncol       Date:  2013-04-02       Impact factor: 3.481

4.  Optimal slice thickness for cone-beam CT with on-board imager.

Authors:  Kyt Seet; A Barghi; S Yartsev; J Van Dyk
Journal:  Biomed Imaging Interv J       Date:  2010-07-01

5.  An investigation of image guidance dose for breast radiotherapy.

Authors:  Rosemerie Alvarado; Jeremy T Booth; Regina M Bromley; Helen B Gustafsson
Journal:  J Appl Clin Med Phys       Date:  2013-05-06       Impact factor: 2.102

6.  A feasibility study of hyoscine butylbromide (buscopan) to improve image quality of cone beam computed tomography during abdominal/pelvic Stereotactic Ablative Radiotherapy.

Authors:  Finbar Slevin; Matthew Beasley; Jim Zhong; Eleanor Hudson; Richard Speight; John Lilley; Louise J Murray; Ann M Henry
Journal:  BJR Open       Date:  2021-07-29

7.  Assessment of positional reproducibility in the head and neck on a 1.5-T MR simulator for an offline MR-guided radiotherapy solution.

Authors:  Yihang Zhou; Jing Yuan; Oi Lei Wong; Winky Wing Ki Fung; Ka Fai Cheng; Kin Yin Cheung; Siu Ki Yu
Journal:  Quant Imaging Med Surg       Date:  2018-10

8.  Comparison of automatic image registration uncertainty for three IGRT systems using a male pelvis phantom.

Authors:  Jeffrey Barber; Jonathan R Sykes; Lois Holloway; David I Thwaites
Journal:  J Appl Clin Med Phys       Date:  2016-09-08       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.