Literature DB >> 19926285

Apparatus for monitoring load bearing rehabilitation exercises of a transfemoral amputee fitted with an osseointegrated fixation: a proof-of-concept study.

Laurent Frossard1, David Lee Gow, Kerstin Hagberg, Nicola Cairns, Bill Contoyannis, Steven Gray, Richard Brånemark, Mark Pearcy.   

Abstract

The purpose of this proof-of-concept study was to determine the relevance of direct measurements to monitor the load applied on the osseointegrated fixation of transfemoral amputees during static load bearing exercises. The objectives were (A) to introduce an apparatus using a three-dimensional load transducer, (B) to present a range of derived information relevant to clinicians, (C) to report on the outcomes of a pilot study and (D) to compare the measurements from the transducer with those from the current method using a weighing scale. One transfemoral amputee fitted with an osseointegrated implant was asked to apply 10 kg, 20 kg, 40 kg and 80 kg on the fixation, using self-monitoring with the weighing scale. The loading was directly measured with a portable kinetic system including a six-channel transducer, external interface circuitry and a laptop. As the load prescribed increased from 10 kg to 80 kg, the forces and moments applied on and around the antero-posterior axis increased by four-fold anteriorly and 14-fold medially, respectively. The forces and moments applied on and around the medio-lateral axis increased by nine-fold laterally and 16-fold from anterior to posterior, respectively. The long axis of the fixation was overloaded and underloaded in 17% and 83% of the trials, respectively, by up to + or - 10%. This proof-of-concept study presents an apparatus that can be used by clinicians facing the challenge of improving basic knowledge on osseointegration, for the design of equipment for load bearing exercises and for rehabilitation programs. Copyright 2009 Elsevier B.V. All rights reserved.

Mesh:

Year:  2009        PMID: 19926285     DOI: 10.1016/j.gaitpost.2009.10.010

Source DB:  PubMed          Journal:  Gait Posture        ISSN: 0966-6362            Impact factor:   2.840


  8 in total

1.  An animal model to evaluate skin-implant-bone integration and gait with a prosthesis directly attached to the residual limb.

Authors:  Brad J Farrell; Boris I Prilutsky; Robert S Kistenberg; John F Dalton; Mark Pitkin
Journal:  Clin Biomech (Bristol, Avon)       Date:  2013-12-23       Impact factor: 2.063

Review 2.  Implantable biosensors for musculoskeletal health.

Authors:  Kylie E Nash; Keat Ghee Ong; Robert E Guldberg
Journal:  Connect Tissue Res       Date:  2022-02-17       Impact factor: 3.417

3.  Development of a Procedure for the Government Provision of Bone-Anchored Prosthesis Using Osseointegration in Australia.

Authors:  Laurent Frossard; Gregory Merlo; Tanya Quincey; Brendan Burkett; Debra Berg
Journal:  Pharmacoecon Open       Date:  2017-12

4.  Editorial: Bionics limb prostheses: Advances in clinical and prosthetic care.

Authors:  Laurent Frossard; Silvia Conforto; Oskar C Aszmann
Journal:  Front Rehabil Sci       Date:  2022-08-18

5.  The Evaluation of Daily Life Activities after Application of an Osseointegrated Prosthesis Fixation in a Bilateral Transfemoral Amputee: A Case Study.

Authors:  Stephanie A F Schalk; Niels Jonkergouw; Fred van der Meer; Willem M Swaan; Horst-H Aschoff; Peter van der Wurff
Journal:  Medicine (Baltimore)       Date:  2015-09       Impact factor: 1.817

6.  Noncontact Strain Monitoring of Osseointegrated Prostheses.

Authors:  Sumit Gupta; Han-Joo Lee; Kenneth J Loh; Michael D Todd; Joseph Reed; A Drew Barnett
Journal:  Sensors (Basel)       Date:  2018-09-09       Impact factor: 3.576

7.  Loading characteristics data applied on osseointegrated implant by transfemoral bone-anchored prostheses fitted with basic components during daily activities.

Authors:  Laurent Frossard
Journal:  Data Brief       Date:  2019-09-11

8.  Inter-participant variability data in loading applied on osseointegrated implant by transtibial bone-anchored prostheses during daily activities.

Authors:  Laurent Frossard; Barry Leech; Mark Pitkin
Journal:  Data Brief       Date:  2019-09-20
  8 in total