Literature DB >> 19923515

The Flex-It stylet is less effective than a malleable stylet for orotracheal intubation using the GlideScope.

Timothy P Turkstra1, Philip M Jones, Katherine M Ower, Michelle L Gros.   

Abstract

BACKGROUND: The GlideScope videolaryngoscope (Verathon Medical, Bothell, WA) usually provides excellent glottic visualization, but directing an endotracheal tube through the vocal cords can be challenging. The goal of the study was to compare the dedicated Flex-It stylet (FIS, Parker Medical, Highlands Ranch, CO) with a malleable stylet, as assessed by time to intubation (TTI).
METHODS: Eighty patients requiring orotracheal intubation for elective surgery were randomly allocated to either the FIS or a malleable stylet (control) to facilitate tracheal intubation using the GlideScope. TTI was recorded by blinded assessors; operators were blinded until after laryngoscopy. The operator assessed the ease of intubation using a 100-mm visual analog scale (0 = easy to 100 = difficult). The number of intubation attempts, number of failures, glottic grades, and use of external laryngeal manipulation were documented.
RESULTS: The median TTI was 41 s (interquartile range [IQR] 30-51) for the Flex-It group compared with 32 s (IQR 28-42) for the control group (P = 0.03). The median visual analog scale score for ease of intubation was 20 (IQR 11-39) for the Flex-It group compared with 15 (IQR 8-28) for the control group (P = 0.13). The overall incidence of a Cormack-Lehane Grade I or II glottic view was 100%.
CONCLUSIONS: In a group of experienced operators using the GlideScope, the FIS was less effective for orotracheal intubation than a malleable endotracheal tube stylet.

Entities:  

Mesh:

Year:  2009        PMID: 19923515     DOI: 10.1213/ANE.0b013e3181bc116a

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  5 in total

1.  The video laryngoscopes, blind spots and retromolar trigonum injury by the GlideRite(®) rigid stylet.

Authors:  Magboul M A Magboul; Shaw Joel
Journal:  Anesth Essays Res       Date:  2010 Jul-Dec

2.  Parker Flex-It stylet is as effective as GlideRite Rigid stylet for orotracheal intubation by Glidescope.

Authors:  Saad A Sheta; Ashraf A Abdelhalim; Ismail A ElZoughari; Tariq A AlZahrani; Abdulhamid H Al-Saeed
Journal:  Saudi Med J       Date:  2015-12       Impact factor: 1.484

3.  A comparison of the Macintosh laryngoscope, McGrath video laryngoscope, and Pentax Airway Scope in paediatric nasotracheal intubation.

Authors:  Ji Young Yoo; Yun Jeong Chae; Young Bok Lee; Sujin Kim; Jaemoon Lee; Dae Hee Kim
Journal:  Sci Rep       Date:  2018-11-26       Impact factor: 4.379

4.  Comparison between GlideRite® rigid stylet and Parker Flex-It™ stylet to facilitate GlideScope intubation in simulated difficult intubation: a randomized controlled study.

Authors:  Ji Won Bak; Yeonji Noh; Juyoun Kim; Byeongmun Hwang; Seongsik Kang; Heejeong Son; Minsoo Kim
Journal:  Anesth Pain Med (Seoul)       Date:  2021-12-30

5.  A systematic review of the role of videolaryngoscopy in successful orotracheal intubation.

Authors:  David W Healy; Oana Maties; David Hovord; Sachin Kheterpal
Journal:  BMC Anesthesiol       Date:  2012-12-14       Impact factor: 2.217

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.