Literature DB >> 19918907

Motion correction using an enhanced floating navigator and GRAPPA operations.

Wei Lin1, Feng Huang, Peter Börnert, Yu Li, Arne Reykowski.   

Abstract

A method for motion correction in multicoil imaging applications, involving both data collection and reconstruction, is presented. The floating navigator method, which acquires a readout line off center in the phase-encoding direction, is expanded to detect translation/rotation and inconsistent motion. This is done by comparing floating navigator data with a reference k-space region surrounding the floating navigator line, using a correlation measure. The technique of generalized autocalibrating partially parallel acquisition is further developed to correct for a fully sampled, motion-corrupted dataset. The flexibility of generalized autocalibrating partially parallel acquisition kernels is exploited by extrapolating readout lines to fill in missing "pie slices" of k-space caused by rotational motion and regenerating full k-space data from multiple interleaved datasets, facilitating subsequent rigid-body motion correction or proper weighting of inconsistent data (e.g., with through-plane and nonrigid motion). Phantom and in vivo imaging experiments with turbo spin-echo sequence demonstrate the correction of severe motion artifacts.

Mesh:

Year:  2010        PMID: 19918907     DOI: 10.1002/mrm.22200

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  8 in total

1.  Evaluation of 3D fat-navigator based retrospective motion correction in the clinical setting of patients with brain tumors.

Authors:  Carl Glessgen; Daniel Gallichan; Manuela Moor; Nicolin Hainc; Christian Federau
Journal:  Neuroradiology       Date:  2019-01-23       Impact factor: 2.804

2.  Respiratory motion correction for free-breathing 3D abdominal MRI using CNN-based image registration: a feasibility study.

Authors:  Jun Lv; Ming Yang; Jue Zhang; Xiaoying Wang
Journal:  Br J Radiol       Date:  2018-01-31       Impact factor: 3.039

3.  Intrinsic detection of motion in segmented sequences.

Authors:  Jason Mendes; Dennis L Parker
Journal:  Magn Reson Med       Date:  2010-11-03       Impact factor: 4.668

Review 4.  Motion correction in MRI of the brain.

Authors:  F Godenschweger; U Kägebein; D Stucht; U Yarach; A Sciarra; R Yakupov; F Lüsebrink; P Schulze; O Speck
Journal:  Phys Med Biol       Date:  2016-02-11       Impact factor: 3.609

5.  Wavelet-space correlation imaging for high-speed MRI without motion monitoring or data segmentation.

Authors:  Yu Li; Hui Wang; Jean Tkach; David Roach; Jason Woods; Charles Dumoulin
Journal:  Magn Reson Med       Date:  2014-12-02       Impact factor: 4.668

6.  Factors associated with MRI success in children cooled for neonatal encephalopathy and controls.

Authors:  Kathryn Woodward; Arthur P C Spencer; Sally Jary; Ela Chakkarapani
Journal:  Pediatr Res       Date:  2022-07-29       Impact factor: 3.953

7.  Pseudo-projection-driven, self-gated cardiac cine imaging using cartesian golden step phase encoding.

Authors:  Liheng Guo; J Andrew Derbyshire; Daniel A Herzka
Journal:  Magn Reson Med       Date:  2015-10-31       Impact factor: 4.668

8.  Navigator-based reacquisition and estimation of motion-corrupted data: Application to multi-echo spin echo for carotid wall MRI.

Authors:  Robert Frost; Luca Biasiolli; Linqing Li; Katherine Hurst; Mohammad Alkhalil; Robin P Choudhury; Matthew D Robson; Aaron T Hess; Peter Jezzard
Journal:  Magn Reson Med       Date:  2019-11-07       Impact factor: 4.668

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.