Sami Pakarinen1, Lasse Oikarinen, Lauri Toivonen. 1. Department of Cardiology, Helsinki University Central Hospital, Haartmaninkatu 4, PO Box 340, 00029 HUS Helsinki, Finland. sami.pakarinen@hus.fi
Abstract
AIMS: The aim of this study was to evaluate the current short-term (<3 months) complication rate related to cardiac rhythm management (CRM) device implantations. METHODS AND RESULTS: We analysed data of the complications related to all CRM device implantations during 1 year (2006) in a tertiary referral university hospital. In 567 device implantations, pacing system upgrade procedures, or lead revisions, 78 complications occurred in 69 (12.2%) patients. Lead dislodgement, pocket haematoma or bleeding, pneumothorax, and infection were the most common accounting for >80% of all complications. The complication rate was more than twice as high in bradycardia pacemaker (PM) implantations performed by cardiology trainees (17.4%) than by experienced cardiologists (7.7%, P = 0.001). When performed by experienced cardiologists, the complication rate was not higher in implantations of more complex devices compared with that of bradycardia PMs. Fifty-two of the 69 patients needed additional surgical procedures. Altogether, the complications required 504 additional treatment days in hospital. CONCLUSION: In conclusion, our retrospective 1-year single-centre survey shows that short-term implantation-related complications of contemporary device therapy are still frequent, occur much more frequently by trainees than by cardiologists, require a large number of additional surgical procedures, and substantially prolong the hospital stay.
AIMS: The aim of this study was to evaluate the current short-term (<3 months) complication rate related to cardiac rhythm management (CRM) device implantations. METHODS AND RESULTS: We analysed data of the complications related to all CRM device implantations during 1 year (2006) in a tertiary referral university hospital. In 567 device implantations, pacing system upgrade procedures, or lead revisions, 78 complications occurred in 69 (12.2%) patients. Lead dislodgement, pocket haematoma or bleeding, pneumothorax, and infection were the most common accounting for >80% of all complications. The complication rate was more than twice as high in bradycardia pacemaker (PM) implantations performed by cardiology trainees (17.4%) than by experienced cardiologists (7.7%, P = 0.001). When performed by experienced cardiologists, the complication rate was not higher in implantations of more complex devices compared with that of bradycardia PMs. Fifty-two of the 69 patients needed additional surgical procedures. Altogether, the complications required 504 additional treatment days in hospital. CONCLUSION: In conclusion, our retrospective 1-year single-centre survey shows that short-term implantation-related complications of contemporary device therapy are still frequent, occur much more frequently by trainees than by cardiologists, require a large number of additional surgical procedures, and substantially prolong the hospital stay.
Authors: Maria Kotsakou; Ioannis Kioumis; George Lazaridis; Georgia Pitsiou; Sofia Lampaki; Antonis Papaiwannou; Anastasia Karavergou; Kosmas Tsakiridis; Nikolaos Katsikogiannis; Ilias Karapantzos; Chrysanthi Karapantzou; Sofia Baka; Ioannis Mpoukovinas; Vasilis Karavasilis; Aggeliki Rapti; Georgia Trakada; Athanasios Zissimopoulos; Konstantinos Zarogoulidis; Paul Zarogoulidis Journal: Ann Transl Med Date: 2015-03
Authors: Seyed Mohammadreza Hosseini; Kasra Moazzami; Guy Rozen; Jeena Vaid; Ahmed Saleh; Kevin E Heist; Mark Vangel; Jeremy N Ruskin Journal: Eur Heart J Date: 2017-07-14 Impact factor: 29.983
Authors: Marianne H Gillam; Nicole L Pratt; Maria C S Inacio; Sepehr Shakib; Prashanthan Sanders; Dennis H Lau; Elizabeth E Roughead Journal: Clin Cardiol Date: 2018-10-19 Impact factor: 2.882