PURPOSE: The utility of DWI with high b-value in ischemic stroke is still unsettled. The purpose of this study is to compare high b-value (3000) and standard b-value (1000) diffusion-weighted images in patients with ischemic stroke at 3T. MATERIALS AND METHODS: 27 patients with acute stroke who were admitted to the hospital during the first 24h after symptom onset were included in this study. All patients had a brain MRI study with stroke protocol including standard (b=1000) DWI and high b-value (b=3000) DWI sequences at 3T MR scanner. Number and localization of the lesions were assessed MR signal intensities (SI), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), contrast ratio (CR) and apparent diffusion coefficient (ADC) values of the lesions and normal parenchyma on DWI with b=1000 and b=3000 sequences were measured. RESULTS: All patients with acute stroke revealed hyperintense lesions due to restricted diffusion on DWI with both b-values. However, lesions of restricted diffusion were more conspicuous in b=3000 value DWI than b=1000, and additional 4 ischemic lesions were detected on b=3000 DWI. SNR, CNR, SI and also ADC values in both stroke area and normal parenchyma were lower at b=3000 than the value at b=1000. At b=3000, CR was significantly greater than b=1000 images. CONCLUSIONS: Although quantitative analysis shows higher SI, SNR and CNR values with standard b-value (b=1000) diffusion-weighted imaging, using higher b-value may still be beneficial in detecting additional subtle lesions in patients whose clinical findings are not correlated with standard b-value DWI in stroke.
PURPOSE: The utility of DWI with high b-value in ischemic stroke is still unsettled. The purpose of this study is to compare high b-value (3000) and standard b-value (1000) diffusion-weighted images in patients with ischemic stroke at 3T. MATERIALS AND METHODS: 27 patients with acute stroke who were admitted to the hospital during the first 24h after symptom onset were included in this study. All patients had a brain MRI study with stroke protocol including standard (b=1000) DWI and high b-value (b=3000) DWI sequences at 3T MR scanner. Number and localization of the lesions were assessed MR signal intensities (SI), signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), contrast ratio (CR) and apparent diffusion coefficient (ADC) values of the lesions and normal parenchyma on DWI with b=1000 and b=3000 sequences were measured. RESULTS: All patients with acute stroke revealed hyperintense lesions due to restricted diffusion on DWI with both b-values. However, lesions of restricted diffusion were more conspicuous in b=3000 value DWI than b=1000, and additional 4 ischemic lesions were detected on b=3000 DWI. SNR, CNR, SI and also ADC values in both stroke area and normal parenchyma were lower at b=3000 than the value at b=1000. At b=3000, CR was significantly greater than b=1000 images. CONCLUSIONS: Although quantitative analysis shows higher SI, SNR and CNR values with standard b-value (b=1000) diffusion-weighted imaging, using higher b-value may still be beneficial in detecting additional subtle lesions in patients whose clinical findings are not correlated with standard b-value DWI in stroke.
Authors: Thomas Sartoretti; Elisabeth Sartoretti; Michael Wyss; Manoj Mannil; Luuk van Smoorenburg; Barbara Eichenberger; Carolin Reischauer; Alex Alfieri; Christoph Binkert; Sabine Sartoretti-Schefer Journal: Br J Radiol Date: 2021-02-17 Impact factor: 3.039
Authors: Jessica L Wisnowski; Stefan Bluml; Ashok Panigrahy; Amit M Mathur; Jeffrey Berman; Ping-Sun Keven Chen; James Dix; Trevor Flynn; Stanley Fricke; Seth D Friedman; Hayden W Head; Chang Y Ho; Beth Kline-Fath; Michael Oveson; Richard Patterson; Sumit Pruthi; Nancy Rollins; Yanerys M Ramos; John Rampton; Jerome Rusin; Dennis W Shaw; Mark Smith; Jean Tkach; Shreyas Vasanawala; Arastoo Vossough; Matthew T Whitehead; Duan Xu; Kristen Yeom; Bryan Comstock; Patrick J Heagerty; Sandra E Juul; Yvonne W Wu; Robert C McKinstry Journal: BMJ Open Date: 2021-04-22 Impact factor: 2.692