Literature DB >> 19911024

Fourier Domain Optical Coherence Tomography integrated into a slit lamp; a novel technique combining anterior and posterior segment OCT.

M Stehouwer1, F D Verbraak, H de Vries, P H B Kok, T G van Leeuwen.   

Abstract

PURPOSE: Fourier Domain Optical Coherence Tomography (FD-OCT) provides high resolution cross-sectional images of the retina and the anterior segment. It has become an important tool in ophthalmology in the examination, diagnosis, and treatment of important and common diseases. Present OCT imaging systems are stand-alone devices. The aim of this paper is to show the quality of images made with a prototype of a Fourier Domain (FD-) OCT imaging system (SLSCAN-1) integrated into a slit lamp.
METHODS: Different representative pathologies of the posterior and anterior segment were observed with the slit lamp and simultaneously scanned with a prototype of the slit lamp-integrated FD-OCT system. The clinical interpretation of posterior segment images made with the prototype were compared to those obtained with a stand-alone FD-system (3D-OCT-1000 Mark II, Topcon).
RESULTS: Images made with the slit lamp-integrated FD-OCT were of sufficient quality to allow for a correct interpretation of the observed pathological conditions. Conclusions based on the images of the posterior segment of the prototype were identical to the conclusions based on the images of a stand-alone FD-system (3D-OCT-1000 Mark II, Topcon). In addition to the images of the posterior segment, images could be made of the anterior segment. The OCT system did not interfere with the normal functionality of the slit lamp.
CONCLUSION: The slit lamp-integrated FD-OCT system provided high quality images of both the anterior and the posterior segment. Scans made with the slit lamp-integrated FD-OCT system could be of use in clinical practice.

Entities:  

Mesh:

Year:  2009        PMID: 19911024     DOI: 10.1038/eye.2009.269

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  5 in total

1.  Scanning beyond the limits of standard OCT with a Fourier domain optical coherence tomography integrated into a slit lamp: the SL SCAN-1.

Authors:  M Stehouwer; F D Verbraak; H R de Vries; T G van Leeuwen
Journal:  Eye (Lond)       Date:  2010-11-12       Impact factor: 3.775

2.  Ultrahigh-resolution optical coherence tomography/angiography with an economic and compact supercontinuum laser.

Authors:  Tai-Ang Wang; Ming-Che Chan; Hsiang-Chieh Lee; Cheng-Yu Lee; Meng-Tsan Tsai
Journal:  Biomed Opt Express       Date:  2019-10-11       Impact factor: 3.732

Review 3.  Angle imaging: advances and challenges.

Authors:  Desmond T L Quek; Monisha E Nongpiur; Shamira A Perera; Tin Aung
Journal:  Indian J Ophthalmol       Date:  2011-01       Impact factor: 1.848

4.  The fundus slit lamp.

Authors:  Marcus-Matthias Gellrich
Journal:  Springerplus       Date:  2015-02-03

5.  Detecting signs of retinal leakage in exudative AMD using Cirrus OCT versus SL SCAN-1, a novel integrated FD-OCT into a common slit lamp.

Authors:  M Stehouwer; F D Verbraak; R O Schlingemann; T G van Leeuwen
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-04-23       Impact factor: 3.117

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.