Ultrahigh-resolution optical coherence tomography/angiography with an economic and compact supercontinuum laser.

Tai-Ang Wang1,2, Ming-Che Chan1,2, Hsiang-Chieh Lee3,4, Cheng-Yu Lee5, Meng-Tsan Tsai5,6.   

Abstract

In this study, a Q-switch pumped supercontinuum laser (QS-SCL) is used as a light source for in vivo imaging via ultrahigh-resolution optical coherence tomography and angiography (UHR-OCT/OCTA). For this purpose, an OCT system based on a spectral-domain detection scheme is constructed, and a spectrometer with a spectral range of 635 - 875 nm is designed. The effective full-width at half maximum of spectrum covers 150 nm, and the corresponding axial and transverse resolutions are 2 and 10 µm in air, respectively. The relative intensity noise of the QS-SCL and mode-locked SCL is quantitatively compared. Furthermore, a special processing algorithm is developed to eliminate the intrinsic noise of QS-SCL. This work demonstrates that QS-SCLs can effectively reduce the cost and size of UHR-OCT/OCTA instruments, making clinical applications feasible.
© 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement.

Year:  2019        PMID: 31799040      PMCID: PMC6865110          DOI: 10.1364/BOE.10.005687

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  40 in total

1.  Ultrahigh resolution optical coherence tomography imaging with a broadband superluminescent diode light source.

Authors:  Tony Ko; Desmond Adler; James Fujimoto; Dmitry Mamedov; Viatcheslav Prokhorov; Vladimir Shidlovski; Sergei Yakubovich
Journal:  Opt Express       Date:  2004-05-17       Impact factor: 3.894

2.  Optical coherence tomography.

Authors:  D Huang; E A Swanson; C P Lin; J S Schuman; W G Stinson; W Chang; M R Hee; T Flotte; K Gregory; C A Puliafito
Journal:  Science       Date:  1991-11-22       Impact factor: 47.728

Review 3.  Review of adaptive optics OCT (AO-OCT): principles and applications for retinal imaging [Invited].

Authors:  Michael Pircher; Robert J Zawadzki
Journal:  Biomed Opt Express       Date:  2017-04-19       Impact factor: 3.732

4.  Characterization of human cutaneous tissue autofluorescence: implications in topical drug delivery studies with fluorescence microscopy.

Authors:  Maiko Hermsmeier; Sinyoung Jeong; Akira Yamamoto; Xin Chen; Usha Nagavarapu; Conor L Evans; Kin F Chan
Journal:  Biomed Opt Express       Date:  2018-10-12       Impact factor: 3.732

5.  Ultrahigh-resolution OCT imaging of the human cornea.

Authors:  René M Werkmeister; Sabina Sapeta; Doreen Schmidl; Gerhard Garhöfer; Gerald Schmidinger; Valentin Aranha Dos Santos; Gerold C Aschinger; Isabella Baumgartner; Niklas Pircher; Florian Schwarzhans; Anca Pantalon; Harminder Dua; Leopold Schmetterer
Journal:  Biomed Opt Express       Date:  2017-01-30       Impact factor: 3.732

6.  Q-switch-pumped supercontinuum for ultra-high resolution optical coherence tomography.

Authors:  Michael Maria; Ivan Bravo Gonzalo; Thomas Feuchter; Mark Denninger; Peter M Moselund; Lasse Leick; Ole Bang; Adrian Podoleanu
Journal:  Opt Lett       Date:  2017-11-15       Impact factor: 3.776

7.  Angiographic and structural imaging using high axial resolution fiber-based visible-light OCT.

Authors:  Shaohua Pi; Acner Camino; Miao Zhang; William Cepurna; Gangjun Liu; David Huang; John Morrison; Yali Jia
Journal:  Biomed Opt Express       Date:  2017-09-20       Impact factor: 3.732

8.  Imaging the subcellular structure of human coronary atherosclerosis using micro-optical coherence tomography.

Authors:  Linbo Liu; Joseph A Gardecki; Seemantini K Nadkarni; Jimmy D Toussaint; Yukako Yagi; Brett E Bouma; Guillermo J Tearney
Journal:  Nat Med       Date:  2011-07-10       Impact factor: 53.440

9.  In vivo investigation of temporal effects and drug delivery induced by transdermal microneedles with optical coherence tomography.

Authors:  Meng-Tsan Tsai; I-Chi Lee; Zhung-Fu Lee; Hao-Li Liu; Chun-Chieh Wang; Yo-Chun Choia; Hsin-Yi Chou; Jiann-Der Lee
Journal:  Biomed Opt Express       Date:  2016-04-15       Impact factor: 3.732

Review 10.  Visible-light optical coherence tomography: a review.

Authors:  Xiao Shu; Lisa Beckmann; Hao Zhang
Journal:  J Biomed Opt       Date:  2017-12       Impact factor: 3.170

View more
  2 in total

1.  Millimeter-scale chip-based supercontinuum generation for optical coherence tomography.

Authors:  Xingchen Ji; Diana Mojahed; Yoshitomo Okawachi; Alexander L Gaeta; Christine P Hendon; Michal Lipson
Journal:  Sci Adv       Date:  2021-09-17       Impact factor: 14.136

2.  Accurate In Vivo Bowman's Thickness Measurement Using Mirau Ultrahigh Axial Resolution Line Field Optical Coherence Tomography.

Authors:  Samuel Lawman; Sharon Mason; Stephen B Kaye; Yao-Chun Shen; Yalin Zheng
Journal:  Transl Vis Sci Technol       Date:  2022-08-01       Impact factor: 3.048

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.