Literature DB >> 19902914

Surface-enhanced transmission mode desorption electrospray ionization: increasing the specificity of ambient ionization mass spectrometric analyses.

Joseph E Chipuk, Michael H Gelb, Jennifer S Brodbelt.   

Abstract

Fabrication and utilization of mesh materials specifically designed to capture analytes from solution facilitates the direct coupling of affinity capture and ambient ionization mass spectrometry via surface-enhanced transmission mode desorption electrospray ionization (TM-DESI). Incorporation of photolabile groups within the linkage between the mesh surface and the covalently modified reactive probe affords facile release of mass tagged analytes directly to mesh surfaces that have been rinsed free of matrix interferences. The approach introduces increased specificity to the already rapid TM-DESI analysis technique, resulting in a powerful tool for high-throughput screening of targeted analytes. Specific capture of thiols is discussed herein, but the surface-enhanced TM-DESI technique can be readily extended to other functional groups by alteration of the capture agent.

Entities:  

Mesh:

Substances:

Year:  2010        PMID: 19902914      PMCID: PMC2800855          DOI: 10.1021/ac902101e

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  10 in total

1.  Absolute quantification of specific proteins in complex mixtures using visible isotope-coded affinity tags.

Authors:  Yu Lu; Patricia Bottari; Frantisek Turecek; Ruedi Aebersold; Michael H Gelb
Journal:  Anal Chem       Date:  2004-07-15       Impact factor: 6.986

2.  Versatile new ion source for the analysis of materials in open air under ambient conditions.

Authors:  Robert B Cody; James A Laramée; H Dupont Durst
Journal:  Anal Chem       Date:  2005-04-15       Impact factor: 6.986

Review 3.  Detection Technologies. Ambient mass spectrometry.

Authors:  R Graham Cooks; Zheng Ouyang; Zoltan Takats; Justin M Wiseman
Journal:  Science       Date:  2006-03-17       Impact factor: 47.728

4.  Transmission mode desorption electrospray ionization.

Authors:  Joseph E Chipuk; Jennifer S Brodbelt
Journal:  J Am Soc Mass Spectrom       Date:  2008-07-10       Impact factor: 3.109

5.  Reactive desorption electrospray ionization linear ion trap mass spectrometry of latest-generation counterfeit antimalarials via noncovalent complex formation.

Authors:  Leonard Nyadong; Michael D Green; Victor R De Jesus; Paul N Newton; Facundo M Fernández
Journal:  Anal Chem       Date:  2007-02-01       Impact factor: 6.986

6.  Mass spectrometry sampling under ambient conditions with desorption electrospray ionization.

Authors:  Zoltán Takáts; Justin M Wiseman; Bogdan Gologan; R Graham Cooks
Journal:  Science       Date:  2004-10-15       Impact factor: 47.728

7.  Rapid screening of anabolic steroids in urine by reactive desorption electrospray ionization.

Authors:  Guangming Huang; Hao Chen; Xinrong Zhang; R Graham Cooks; Zheng Ouyang
Journal:  Anal Chem       Date:  2007-10-05       Impact factor: 6.986

8.  The influence of material and mesh characteristics on transmission mode desorption electrospray ionization.

Authors:  Joseph E Chipuk; Jennifer S Brodbelt
Journal:  J Am Soc Mass Spectrom       Date:  2008-12-03       Impact factor: 3.109

9.  Rapid, direct analysis of cholesterol by charge labeling in reactive desorption electrospray ionization.

Authors:  Chunping Wu; Demian R Ifa; Nicholas E Manicke; R Graham Cooks
Journal:  Anal Chem       Date:  2009-09-15       Impact factor: 6.986

10.  Photocleavable biotin derivatives: a versatile approach for the isolation of biomolecules.

Authors:  J Olejnik; S Sonar; E Krzymañska-Olejnik; K J Rothschild
Journal:  Proc Natl Acad Sci U S A       Date:  1995-08-01       Impact factor: 11.205

  10 in total
  5 in total

1.  Multistage Reactive Transmission-Mode Desorption Electrospray Ionization Mass Spectrometry.

Authors:  Kevin C Peters; Troy J Comi; Richard H Perry
Journal:  J Am Soc Mass Spectrom       Date:  2015-06-20       Impact factor: 3.109

Review 2.  Mass spectrometry imaging under ambient conditions.

Authors:  Chunping Wu; Allison L Dill; Livia S Eberlin; R Graham Cooks; Demian R Ifa
Journal:  Mass Spectrom Rev       Date:  2012-09-20       Impact factor: 10.946

3.  Rapid and selective screening for sulfhydryl analytes in plasma and urine using surface-enhanced transmission mode desorption electrospray ionization mass spectrometry.

Authors:  Joseph E Chipuk; Michael H Gelb; Jennifer S Brodbelt
Journal:  Anal Chem       Date:  2010-05-15       Impact factor: 6.986

4.  Polymer-spray mass spectrometric detection and quantitation of hydrophilic compounds and some narcotics.

Authors:  Maria T Dulay; Richard N Zare
Journal:  Rapid Commun Mass Spectrom       Date:  2017-10-15       Impact factor: 2.419

Review 5.  Emerging trends in paper spray mass spectrometry: Microsampling, storage, direct analysis, and applications.

Authors:  Benjamin S Frey; Deidre E Damon; Abraham K Badu-Tawiah
Journal:  Mass Spectrom Rev       Date:  2019-09-06       Impact factor: 10.946

  5 in total