Literature DB >> 19894094

Amount of adsorbed albumin loss by dialysis membranes with protein adsorption.

Narumi Tomisawa1, Akihiro C Yamashita.   

Abstract

Polymethylmethacrylate (PMMA) membrane is the first synthetic polymeric hollow fiber used in dialyzers that is known to adsorb beta(2)-microglobulin. Polyester polymer alloy (PEPA), a blend of two polymers, i.e., polyarylate and polyethersulfone, is another dialysis membrane material with adsorption characteristics. In this study, the adsorption and permeation characteristics of BG-1.6PQ (PMMA) and FLX-15GW (PEPA) dialyzers were investigated by performing ultrafiltration experiments using chymotrypsinogen (molecular weight 25,000) and albumin (molecular weight 66,000) as test solutes. Although PMMA and PEPA had the same sieving coefficient for chymotrypsinogen at steady state, PMMA showed approximately 20% higher fractional adsorption than PEPA under the same initial concentrations. The fractional adsorption for albumin was approximately 20% in PEPA regardless of the ultrafiltration flow rate. The fractional adsorption for albumin in PMMA, however, increased as the ultrafiltration flow rate increased and reached 50%-60% after 10 h. Since PEPA has two skins, one inside and one outside the hollow fiber, proteins may have been adsorbed mainly by these two layers. However, since PMMA is a uniform membrane and since the higher the ultrafiltration flow rate, the higher the fractional adsorption found in PMMA, adsorption may be the result of the occlusion of the dense structure of the membrane. The amount of albumin loss is often clinically evaluated by measuring the amount of permeated albumin in the dialysate. However, when dialyzers with adsorption characteristics are examined, the loss by adsorption should also be taken into account.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19894094     DOI: 10.1007/s10047-009-0469-0

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  7 in total

1.  Current topics on cytokine removal technologies.

Authors:  K Matsuda; H Hirasawa; S Oda; H Shiga; K Nakanishi
Journal:  Ther Apher       Date:  2001-08

2.  Membrane fouling and dialysate flow pattern in an internal filtration-enhancing dialyzer.

Authors:  Ken-ichiro Yamamoto; Michihito Hiwatari; Fukashi Kohori; Kiyotaka Sakai; Makoto Fukuda; Tatsuo Hiyoshi
Journal:  J Artif Organs       Date:  2005       Impact factor: 1.731

3.  A new form of amyloid protein associated with chronic hemodialysis was identified as beta 2-microglobulin.

Authors:  F Gejyo; T Yamada; S Odani; Y Nakagawa; M Arakawa; T Kunitomo; H Kataoka; M Suzuki; Y Hirasawa; T Shirahama
Journal:  Biochem Biophys Res Commun       Date:  1985-06-28       Impact factor: 3.575

Review 4.  Continuous hemodiafiltration with cytokine-adsorbing hemofilter in the treatment of severe sepsis and septic shock.

Authors:  Hiroyuki Hirasawa; Shigeto Oda; Kenichi Matsuda
Journal:  Contrib Nephrol       Date:  2007       Impact factor: 1.580

5.  New polymer alloy dialysis membranes with varying permeabilities and sievings.

Authors:  M Shimizu; T Kanamori; K Sakai; T Igoshi; M Yoshida
Journal:  ASAIO J       Date:  1992 Oct-Dec       Impact factor: 2.872

Review 6.  Clinical significance of protein adsorbable membranes--long-term clinical effects and analysis using a proteomic technique.

Authors:  Ikuo Aoike
Journal:  Nephrol Dial Transplant       Date:  2007-07       Impact factor: 5.992

7.  Continuous hemodiafiltration with PMMA Hemofilter in the treatment of patients with septic shock.

Authors:  Taka-Aki Nakada; Shigeto Oda; Ken-Ichi Matsuda; Tomohito Sadahiro; Masataka Nakamura; Ryuzo Abe; Hiroyuki Hirasawa
Journal:  Mol Med       Date:  2008 May-Jun       Impact factor: 6.354

  7 in total
  8 in total

Review 1.  Journal of Artificial Organs 2009: the year in review.

Authors: 
Journal:  J Artif Organs       Date:  2010-03-24       Impact factor: 1.731

2.  Replication of fouling in vitro in hollow fiber dialyzers by albumin immobilization.

Authors:  Takayoshi Kiguchi; Narumi Tomisawa; Akihiro C Yamashita
Journal:  J Artif Organs       Date:  2022-02-11       Impact factor: 1.731

3.  Semi-Quantitative Evaluation of Asymmetricity of Dialysis Membrane Using Forward and Backward Ultrafiltration.

Authors:  Akihiro C Yamashita; Toshiki Kakee; Takahisa Ono; Jun Motegi; Satoru Yamaguchi; Takashi Sunohara
Journal:  Membranes (Basel)       Date:  2022-06-15

Review 4.  Reconsidering adsorption in hemodialysis: is it just an epiphenomenon? A narrative review.

Authors:  Nans Florens; Fitsum Guebre-Egziabher; L Juillard
Journal:  J Nephrol       Date:  2021-04-10       Impact factor: 3.902

5.  Cardiac troponin I but not cardiac troponin T adheres to polysulfone dialyser membranes in an in vitro haemodialysis model: explanation for lower serum cTnI concentrations following dialysis.

Authors:  David C Gaze; Paul O Collinson
Journal:  Open Heart       Date:  2014-06-12

6.  Assessment of removal and adsorption enhancement of high-flux hemodialyzers in convective therapies by a novel in vitro uremic matrix.

Authors:  Miquel Gomez; Elisenda Bañon-Maneus; Marta Arias-Guillén; Francisco Maduell
Journal:  Sci Rep       Date:  2020-10-15       Impact factor: 4.379

Review 7.  Slipping Through the Pores: Hypoalbuminemia and Albumin Loss During Hemodialysis.

Authors:  Kamyar Kalantar-Zadeh; Linda H Ficociello; Jennifer Bazzanella; Claudy Mullon; Michael S Anger
Journal:  Int J Nephrol Renovasc Dis       Date:  2021-01-20

8.  Effect of Membrane Surface Area on Solute Removal Performance of Dialyzers with Fouling.

Authors:  Takayoshi Kiguchi; Hiromi Ito; Akihiro C Yamashita
Journal:  Membranes (Basel)       Date:  2022-07-01
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.