Literature DB >> 1988635

Clinical validation of a miniature nuclear probe system for continuous on-line monitoring of cardiac function and ST-segment.

P Broadhurst1, P Cashman, J Crawley, E Raftery, A Lahiri.   

Abstract

A new, miniature cesium iodide/photodiode nuclear probe (the "Cardioscint") has been developed for continuous on-line measurement of left ventricular function and the ST-segment. Ejection fraction (EF) measurements in 77 patients were compared with gated equilibrium radionuclide ventriculograms. The probe was positioned over the left ventricle by first using a blind positioning algorithm and then by using the gamma camera. Background was measured both manually and automatically. There was good correlation between probe (positioned blind) and gamma camera EF with both manual (r = 0.80, n = 65) and automatic (r = 0.78, n = 66) backgrounds. Use of the gamma camera did not significantly alter the results. Correlation between the probe stroke counts and thermodilution-derived stroke index during atrial pacing in six subjects was also satisfactory (r = 0.69, n = 102). Thus, the Cardioscint is able to provide a reliable estimate of EF and can track rapid changes in cardiac volumes.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1988635

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  5 in total

1.  Nonperfusion applications in nuclear cardiology: report of a task force of the American Society of Nuclear Cardiology.

Authors:  E G DePuey; S Port; F J Wackers; A Rozanski; E H Botvinick; M W Dae; N Tamaki
Journal:  J Nucl Cardiol       Date:  1998 Mar-Apr       Impact factor: 5.952

2.  Monitoring of left ventricular ejection fraction with a miniature, nonimaging nuclear detector: accuracy and reliability over time with special reference to blood labeling.

Authors:  T B Lindhardt; B Hesse; N Gadsbøll
Journal:  J Nucl Cardiol       Date:  1997 Mar-Apr       Impact factor: 5.952

3.  RF-transmitted CsI radio-isotopic ambulatory recorder for left ventricular ejection fraction monitoring.

Authors:  H Bedoui; J Rousseau; A Millaire; C Foucher; G Ducloux; X Marchandise
Journal:  Med Biol Eng Comput       Date:  1995-01       Impact factor: 2.602

4.  A system for postoperative visualization and analysis of left ventricular pressure-volume loops.

Authors:  B B Beard; J R Stewart; T A Fischell
Journal:  Comput Biol Med       Date:  1998-01       Impact factor: 4.589

5.  Rate of change of left ventricular ejection fraction during exercise is superior to the peak ejection fraction for predicting functionally significant coronary artery disease.

Authors:  B S Sridhara; S Bhattacharya; X J Liu; P Broadhurst; A Lahiri
Journal:  Br Heart J       Date:  1993-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.