Literature DB >> 19886143

Increased incidence of pancreatic fistulas after the introduction of a bioabsorbable staple line reinforcement in distal pancreatic resections.

Eduardo A Guzman1, Rebecca A Nelson, Joseph Kim, Alessio Pigazzi, Vijay Trisal, Benjamin Paz, Joshua Di Ellenhorn.   

Abstract

Pancreatic fistula is a major cause of morbidity after distal pancreatic resection. When resections are performed with linear stapling devices, the use of bioabsorbable staple line reinforcement has been suggested to decrease the rate of pancreatic fistula. Our objective was to investigate the incidence of pancreatic fistula when using the Gore Seamguard staple line reinforcement in stapled distal pancreatic resections. A retrospective review of 30 consecutive patients with stapled distal pancreatectomy was conducted. A broad definition of pancreatic fistula was used. Clinicopathologic factors and outcomes were compared between groups. Pancreatic fistula was diagnosed in 11 of 15 patients (73%) and three of 15 patients (20%) in the Seamguard and non-Seamguard groups, respectively (P = 0.002). Pancreatic parenchymal transection at the neck of the gland was associated with pancreatic fistula, whereas laparoscopic procedures, splenic preservation, or additional organ resection were not. On multivariate analysis, the association between Seamguard use and pancreatic fistula was significant (P = 0.005). In conclusion, after introduction of the Gore Seamguard bioabsorbable staple line reinforcement, we experienced a significant increase in the rate of pancreatic fistula. This experience raises concern about the efficacy of this device in limiting pancreatic fistula after stapled distal pancreatic resection.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19886143

Source DB:  PubMed          Journal:  Am Surg        ISSN: 0003-1348            Impact factor:   0.688


  12 in total

1.  The influence of staple size on fistula formation following distal pancreatectomy.

Authors:  Boris Sepesi; Jacob Moalem; Eva Galka; Peter Salzman; Luke O Schoeniger
Journal:  J Gastrointest Surg       Date:  2011-10-21       Impact factor: 3.452

Review 2.  Minireview on laparoscopic hepatobiliary and pancreatic surgery.

Authors:  Clara Tan-Tam; Stephen W Chung
Journal:  World J Gastrointest Endosc       Date:  2014-03-16

Review 3.  Attempts to prevent postoperative pancreatic fistula after distal pancreatectomy.

Authors:  Yoshihiro Miyasaka; Yasuhisa Mori; Kohei Nakata; Takao Ohtsuka; Masafumi Nakamura
Journal:  Surg Today       Date:  2016-06-20       Impact factor: 2.549

4.  Reinforced staplers for distal pancreatectomy.

Authors:  Manabu Kawai; Seiko Hirono; Ken-Ichi Okada; Sohei Satoi; Hiroaki Yanagimoto; Masanori Kon; Yoshiaki Murakami; Naru Kondo; Masayuki Sho; Takahiro Akahori; Hirochika Toyama; Takumi Fukumoto; Tsutomu Fujii; Ippei Matsumoto; Hidetoshi Eguchi; Hisashi Ikoma; Yutaka Takeda; Jiro Fujimoto; Hiroki Yamaue
Journal:  Langenbecks Arch Surg       Date:  2017-11-04       Impact factor: 3.445

5.  Laparoscopic distal pancreatectomy and splenectomy for malignant tumors.

Authors:  Andrew A Gumbs; Elie K Chouillard
Journal:  J Gastrointest Cancer       Date:  2012-03

6.  Meta-analysis of bioabsorbable staple line reinforcement and risk of fistula following pancreatic resection.

Authors:  Eric H Jensen; Pamela R Portschy; Jessica Chowaniec; Ming Teng
Journal:  J Gastrointest Surg       Date:  2012-09-05       Impact factor: 3.452

7.  Totally laparoscopic stapled distal pancreatectomy.

Authors:  Hirokatsu Katagiri; Akira Sasaki; Hiroyuki Nitta; Takeshi Takahara; Satoshi Nishizuka; Go Wakabayashi
Journal:  Surg Today       Date:  2012-07-13       Impact factor: 2.549

8.  Risk factors of postoperative pancreatic fistula after distal pancreatectomy using a triple-row stapler.

Authors:  Hiromichi Kawaida; Hiroshi Kono; Mitsuaki Watanabe; Naohiro Hosomura; Hidetake Amemiya; Hideki Fujii
Journal:  Surg Today       Date:  2017-06-09       Impact factor: 2.549

9.  Pancreatic stump closure techniques and pancreatic fistula formation after distal pancreatectomy: Meta-analysis and single-center experience.

Authors:  Elke Tieftrunk; Ihsan Ekin Demir; Stephan Schorn; Mine Sargut; Florian Scheufele; Lenika Calavrezos; Rebekka Schirren; Helmut Friess; Güralp O Ceyhan
Journal:  PLoS One       Date:  2018-06-13       Impact factor: 3.240

10.  Effect of polyglycolic acid mesh for prevention of pancreatic fistula after pancreatectomy: A systematic review and meta-analysis.

Authors:  Wei Zhang; Zhicheng Wei; Xu Che
Journal:  Medicine (Baltimore)       Date:  2020-08-21       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.