Literature DB >> 19883917

Fluid-structure interaction in aortic cross-clamping: implications for vessel injury.

Henry Y Chen1, Jose A Navia, Shoaib Shafique, Ghassan S Kassab.   

Abstract

Vascular cross-clamping is applied in many cardiovascular surgeries such as coronary bypass, aorta repair and valve procedures. Experimental studies have found that clamping of various degrees caused damage to arteries. This study examines the effects of popular clamps on vessel wall. Models of the aorta and clamp were created in Computer Assisted Design and Finite Element Analysis packages. The vessel wall was considered as a non-linear anisotropic material while the fluid was simulated as Newtonian with pulsatile flow. The clamp was applied through displacement time function. Fully coupled two-way solid-fluid interaction models were developed. It was found that the clamp design significantly affected the stresses in vessel wall. The clamp with a protrusion feature increased the overall Von Mises stress by about 60% and the compressive stress by more than 200%. Interestingly, when the protrusion clamp was applied, the Von Mises stress at the lumen (endothelium) side of artery wall was about twice that of the outer wall. This ratio was much higher than that of the plate-like clamp which was about 1.3. The flow reversal process was demonstrated during clamping. Vibrations, flow and wall shear stress oscillations were detected immediately before total vessel occlusion. The commonly used protrusion clamp increased stresses in vessel wall, especially the compressive stress. This design also significantly increased the stresses on endothelium, detrimental to vessel health. The present findings are relevant to surgical clamp design as well as the transient mechanical loading on the endothelium and potential injury. The deformation and stress analysis may provide valuable insights into the mode of tissue injury during cross-clamping. Copyright 2009 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 19883917      PMCID: PMC2813350          DOI: 10.1016/j.jbiomech.2009.08.042

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  20 in total

1.  A three-dimensional finite element model for arterial clamping.

Authors:  Thomas C Gasser; Christian A J Schulze-Bauer; Gerhard A Holzapfel
Journal:  J Biomech Eng       Date:  2002-08       Impact factor: 2.097

2.  Fluid-induced shear stress stimulates chondrocyte proliferation partially mediated via TGF-beta1.

Authors:  Prasanna Malaviya; Robert M Nerem
Journal:  Tissue Eng       Date:  2002-08

3.  Assessing clamp-related vascular injuries by measurement of associated vascular dysfunction.

Authors:  G W Barone; J M Conerly; P C Farley; T L Flanagan; I L Kron
Journal:  Surgery       Date:  1989-04       Impact factor: 3.982

4.  Hemodynamic shear stress and its role in atherosclerosis.

Authors:  A M Malek; S L Alper; S Izumo
Journal:  JAMA       Date:  1999-12-01       Impact factor: 56.272

5.  Gaseous and solid cerebral microembolization during proximal aortic anastomoses in off-pump coronary surgery: the effect of an aortic side-biting clamp and two clampless devices.

Authors:  Lorenzo Guerrieri Wolf; Yasir Abu-Omar; Bikram P Choudhary; David Pigott; David P Taggart
Journal:  J Thorac Cardiovasc Surg       Date:  2007-02       Impact factor: 5.209

6.  Intimal injury from arterial clamps.

Authors:  J B Slayback; W W Bowen; D B Hinshaw
Journal:  Am J Surg       Date:  1976-08       Impact factor: 2.565

7.  Management of porcelain aorta and calcified great vessels in coronary artery bypass grafting with off-pump and no-touch technology.

Authors:  H B Bittner; M A Savitt
Journal:  Ann Thorac Surg       Date:  2001-10       Impact factor: 4.330

8.  Extra-anatomic coronary artery bypass graftings in patients with porcelain aorta.

Authors:  E Demirsoy; M Unal; H Arbatli; N Yagan; F Tukenmez; B Sonmez
Journal:  J Cardiovasc Surg (Torino)       Date:  2004-04       Impact factor: 1.888

9.  Thymosin beta4 regulation, expression and function in aortic valve interstitial cells.

Authors:  Quan-Yi Li; Peter L Jones; Robert P Lafferty; Daniel Safer; Robert J Levy
Journal:  J Heart Valve Dis       Date:  2002-09

10.  Arteriographic and ultrasonic evaluation of vascular clamp injuries using an in vitro human experimental model.

Authors:  J C Coelho; B Sigel; D P Flanigan; J J Schuler; J Justin; J Machi
Journal:  Surg Gynecol Obstet       Date:  1982-10
View more
  3 in total

1.  Impact of stent mis-sizing and mis-positioning on coronary fluid wall shear and intramural stress.

Authors:  Henry Y Chen; Bon-Kwon Koo; Deepak L Bhatt; Ghassan S Kassab
Journal:  J Appl Physiol (1985)       Date:  2013-05-30

2.  Acute aortic wall injury caused by aortic cross-clamping: morphological and biomechanical study of the aorta in a swine model of three aortic surgery approaches.

Authors:  Marcela Polachini Prata; Rodrigo Gibin Jaldin; Pedro Luiz Toledo de Arruda Lourenção; Marcone Lima Sobreira; Ricardo de Alvarenga Yoshida; Simone Antunes Terra; Rosa Marlene Viero; Winston Bonetti Yoshida
Journal:  J Vasc Bras       Date:  2020-03-12

3.  Biomechanical and morphological evaluation of aortic wall changes related to the cross-clamping method in different surgical techniques.

Authors:  Pedro Pereira Tenório; Rodrigo Mendes; José Honório de Almeida Palma da Fonseca
Journal:  J Vasc Bras       Date:  2021-12-01
  3 in total