Literature DB >> 19878902

Mechanical characterisation of polyurethane elastomer for biomedical applications.

Valentine Kanyanta1, Alojz Ivankovic.   

Abstract

Mechanical testing and modelling of a material for biomedical applications have to be based on conditions representative of the application of interest. In this work, an ether-based polyurethane elastomer is used to build mock arteries. The aim is to study the behaviour of arteries under pulsatile loading conditions and how that behaviour changes with the development and progression of atherosclerosis. Polyurethane elastomers are widely used as biomaterials, e.g. in tube form for bypasses and catheters. However, their mechanical behaviour has not been extensively characterised. This work establishes the variations in the behaviour of polyurethane elastomer with temperature, humidity and strain rate and also reports planar and equibiaxial tension, relaxation, creep and cyclic test results, providing a comprehensive characterisation of the material. Test results are used to determine the properties of the polyurethane elastomer and in the selection of a representative material model for future simulations of arterial behaviour and the development of atherosclerosis. The results show that the behaviour of the elastomer is significantly dependent on both humidity and temperature, with Young's modulus of 7.4 MPa, 5.3 MPa and 4.7 MPa under dry-room temperature, wet-room temperature and wet at 37 ( composite function)C conditions, respectively. The elastomer also exhibits rate-dependent viscoelastic behaviour. Yeoh's hyperelastic material model provided the best fit to the entire range of experimental data. The Neo-Hookean model provides a good fit at small strain but significantly diverges at large strains. Nevertheless, in applications where deformations are relatively small, i.e. below 15%, the Neo-Hookean model can be used.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19878902     DOI: 10.1016/j.jmbbm.2009.03.005

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  12 in total

1.  Progressive structural and biomechanical changes in elastin degraded aorta.

Authors:  Ming-Jay Chow; Jarred R Mondonedo; Victor M Johnson; Yanhang Zhang
Journal:  Biomech Model Mechanobiol       Date:  2012-05-24

2.  Proteins, platelets, and blood coagulation at biomaterial interfaces.

Authors:  Li-Chong Xu; James W Bauer; Christopher A Siedlecki
Journal:  Colloids Surf B Biointerfaces       Date:  2014-09-28       Impact factor: 5.268

Review 3.  Recent Advances in Stretchable and Wearable Capacitive Electrophysiological Sensors for Long-Term Health Monitoring.

Authors:  Hadaate Ullah; Md A Wahab; Geoffrey Will; Mohammad R Karim; Taisong Pan; Min Gao; Dakun Lai; Yuan Lin; Mahdi H Miraz
Journal:  Biosensors (Basel)       Date:  2022-08-11

4.  Stretchable broadband photo-sensor sheets for nonsampling, source-free, and label-free chemical monitoring by simple deformable wrapping.

Authors:  Kou Li; Teppei Araki; Ryogo Utaki; Yu Tokumoto; Meiling Sun; Satsuki Yasui; Naoko Kurihira; Yuko Kasai; Daichi Suzuki; Ruben Marteijn; Jaap M J den Toonder; Tsuyoshi Sekitani; Yukio Kawano
Journal:  Sci Adv       Date:  2022-05-11       Impact factor: 14.957

5.  Shape Memory Polyurethane-Based Smart Polymer Substrates for Physiologically Responsive, Dynamic Pressure (Re)Distribution.

Authors:  Bipin Kumar; Nuruzzaman Noor; Suman Thakur; Ning Pan; Harishkumar Narayana; Siu-Cheong Yan; Faming Wang; Parth Shah
Journal:  ACS Omega       Date:  2019-09-12

6.  Mechanical Assessment and Hyperelastic Modeling of Polyurethanes for the Early Stages of Vascular Graft Design.

Authors:  Arévalo-Alquichire Said; Dominguez-Paz Carlos; Valero Manuel F
Journal:  Materials (Basel)       Date:  2020-11-05       Impact factor: 3.623

7.  Numerical Assessment of a Safety System to Minimize Injuries during a Cyclist Run-Over.

Authors:  E H López-García; M F Carbajal-Romero; J A Flores-Campos; C R Torres-SanMiguel
Journal:  Appl Bionics Biomech       Date:  2021-08-26       Impact factor: 1.781

Review 8.  Flexible and Stretchable Bioelectronics.

Authors:  Chandani Chitrakar; Eric Hedrick; Lauren Adegoke; Melanie Ecker
Journal:  Materials (Basel)       Date:  2022-02-23       Impact factor: 3.623

9.  Study of the Influence of the Manufacturing Parameters on Tensile Properties of Thermoplastic Elastomers.

Authors:  Bàrbara Adrover-Monserrat; Jordi Llumà; Ramón Jerez-Mesa; J Antonio Travieso-Rodriguez
Journal:  Polymers (Basel)       Date:  2022-01-31       Impact factor: 4.329

10.  A three-dimensional finite-element model of a human dry skull for bone-conduction hearing.

Authors:  Namkeun Kim; You Chang; Stefan Stenfelt
Journal:  Biomed Res Int       Date:  2014-08-27       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.