Effects of orthopedic implants with a polycaprolactone polymer coating containing bone morphogenetic protein-2 on osseointegration in bones of sheep.

Andrew J Niehaus1, David E Anderson, Valerie F Samii, Steven E Weisbrode, Jed K Johnson, Mike S Noon, David L Tomasko, John J Lannutti.   

Abstract

OBJECTIVE: To determine elution characteristics of bone morphogenetic protein (BMP)-2 from a polycaprolactone coating applied to orthopedic implants and determine effects of this coating on osseointegration. ANIMALS: 6 sheep. PROCEDURES: An in vitro study was conducted to determine BMP-2 elution from polycaprolactone-coated implants. An in vivo study was conducted to determine the effects on osseointegration when the polycaprolactone with BMP-2 coating was applied to bone screws. Osseointegration was assessed via radiography, measurement of peak removal torque and bone mineral density, and histomorphometric analysis. Physiologic response was assessed by measuring serum bone-specific alkaline phosphatase activity and uptake of bone markers.
RESULTS: Mean +/- SD elution on day 1 of the in vitro study was 263 +/- 152 pg/d, which then maintained a plateau at 59.8 +/- 29.1 pg/d. Mean peak removal torque for screws coated with polycalprolactone and BMP-2 (0.91 +/- 0.65 dN x m) and screws coated with polycaprolactone alone (0.97 +/- 1.30 dN.m) did not differ significantly from that for the control screws (2.34 +/- 1.62 dN x m). Mean bone mineral densities were 0.535 +/- 0.060 g/cm(2), 0.596 +/- 0.093 g/cm(2), and 0.524 +/- 0.142 g/cm(2) for the polycaprolactone-BMP-2-coated, polycaprolactone-coated, and control screws, respectively, and did not differ significantly among groups. Histologically, bone was in closer apposition to the implant with the control screws than with either of the coated screws. CONCLUSIONS AND CLINICAL RELEVANCE: BMP-2 within the polycaprolactone coating did not stimulate osteogenesis. The polycaprolactone coating appeared to cause a barrier effect that prevented formation of new bone. A longer period or use of another carrier polymer may result in increased osseointegration.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19878025     DOI: 10.2460/ajvr.70.11.1416

Source DB:  PubMed          Journal:  Am J Vet Res        ISSN: 0002-9645            Impact factor:   1.156


  3 in total

Review 1.  [What can be done when hip prostheses fail? : New trends in revision endoprosthetics].

Authors:  S Gravius; T Randau; D C Wirtz
Journal:  Orthopade       Date:  2011-12       Impact factor: 1.087

2.  Synthetic osteogenic extracellular matrix formed by coated silicon dioxide nanosprings.

Authors:  Jamie L Hass; Erin M Garrison; Sarah A Wicher; Ben Knapp; Nathan Bridges; Dn McLlroy; Gustavo Arrizabalaga
Journal:  J Nanobiotechnology       Date:  2012-01-27       Impact factor: 10.435

3.  Reality of dental implant surface modification: a short literature review.

Authors:  In-Sung Yeo
Journal:  Open Biomed Eng J       Date:  2014-10-31
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.