Literature DB >> 19864328

Estimation of skin entrance doses (SEDs) for common medical X-ray diagnostic examinations in India and proposed diagnostic reference levels (DRLs).

A U Sonawane1, V K Shirva, A S Pradhan.   

Abstract

Skin entrance doses (SEDs) were estimated by carrying out measurements of air kerma from 101 X-ray machines installed in 45 major and selected hospitals in the country by using a silicon detector-based dose Test-O-Meter. 1209 number of air kerma measurements of diagnostic projections for adults have been analysed for seven types of common diagnostic examinations, viz. chest (AP, PA, LAT), lumbar spine (AP, LAT), thoracic spine (AP, LAT), abdomen (AP), pelvis (AP), hip joints (AP) and skull (PA, LAT) for different film-screen combinations. The values of estimated diagnostic reference levels (DRLs) (third quartile values of SEDs) were compared with guidance levels/DRLs of doses published by the IAEA-BSS-Safety Series No. 115, 1996; HPA (NRPB) (2000 and 2005), UK; CRCPD/CDRH (USA), European Commission and other national values. The values of DRLs obtained in this study are comparable with the values published by the IAEA-BSS-115 (1996); HPA (NRPB) (2000 and 2005) UK; EC and CRCPD/CDRH, USA including values obtained in previous studies in India.

Entities:  

Mesh:

Year:  2009        PMID: 19864328     DOI: 10.1093/rpd/ncp235

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  6 in total

1.  Radiological safety status and quality assurance audit of medical X-ray diagnostic installations in India.

Authors:  A U Sonawane; Meghraj Singh; J V K Sunil Kumar; Arti Kulkarni; V K Shirva; A S Pradhan
Journal:  J Med Phys       Date:  2010-10

2.  Measurement of Entrance Skin Dose and Calculation of Effective Dose for Common Diagnostic X-Ray Examinations in Kashan, Iran.

Authors:  Akbar Aliasgharzadeh; Ehsan Mihandoost; Mahboubeh Masoumbeigi; Morteza Salimian; Mehran Mohseni
Journal:  Glob J Health Sci       Date:  2015-02-24

3.  Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran.

Authors:  A Janbabanezhad Toori; A Shabestani-Monfared; M R Deevband; R Abdi; M Nabahati
Journal:  J Biomed Phys Eng       Date:  2015-12-01

4.  Local reference dose evaluation in conventional radiography examinations in Iran.

Authors:  M Shirin Shandiz; M T Bahreyni Toosi; S Farsi; K Yaghobi
Journal:  J Appl Clin Med Phys       Date:  2014-03-06       Impact factor: 2.102

5.  Patient dose measurement in common medical X-ray examinations in Iran.

Authors:  Behrouz Rasuli; Ali Mahmoud-Pashazadeh; Mohammad Ghorbani; Raheleh Tabari Juybari; Mozafar Naserpour
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

6.  Radiation dose to patients from X-ray radiographic examinations using computed radiography imaging system.

Authors:  Reena Sharma; Sunil Dutt Sharma; Shramika Pawar; Ajay Chaubey; S Kantharia; D A R Babu
Journal:  J Med Phys       Date:  2015 Jan-Mar
  6 in total