Literature DB >> 19855776

Influence of glucose concentration on light scattering in tissue-simulating phantoms.

M Kohl, M Cope, M Essenpreis, D Böcker.   

Abstract

The presence of glucose dissolved in an aqueous solution increases the refractive index of the solution and therefore has an influence on the scattering properties of any particles suspended within it. We present experimental data on the effect of glucose concentration on the scattering coefficient of a suspension of spherical polystyrene particles. The experimental results are in good agreement with Mie theory. The effect of glucose on light transport in highly scattering, tissue-simulating phantoms is demonstrated both experimentally and theoretically by application of diffusion theory. The possible application of this effect for noninvasive glucose monitoring of diabetic patients is discussed.

Entities:  

Year:  1994        PMID: 19855776     DOI: 10.1364/ol.19.002170

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  7 in total

1.  Continuous noninvasive monitoring of changes in human skin optical properties during oral intake of different sugars with optical coherence tomography.

Authors:  Yuqing Zhang; Guoyong Wu; Huajiang Wei; Zhouyi Guo; Hongqin Yang; Yonghong He; Shusen Xie; Ying Liu
Journal:  Biomed Opt Express       Date:  2014-02-28       Impact factor: 3.732

2.  Scattering-independent glucose absorption measurement using a spectrally resolved reflectance setup with specialized variable source-detector separations.

Authors:  Jin Liu; Caigang Zhu; Jingying Jiang; Kexin Xu
Journal:  Biomed Opt Express       Date:  2018-11-02       Impact factor: 3.732

3.  Polarization-based diffuse reflectance imaging for noninvasive measurement of glucose.

Authors:  Brent D Cameron; Yanfang Li
Journal:  J Diabetes Sci Technol       Date:  2007-11

4.  Specialized source-detector separations in near-infrared reflectance spectroscopy platform enable effective separation of diffusion and absorption for glucose sensing.

Authors:  Jin Liu; Tongshuai Han; Jingying Jiang; Kexin Xu
Journal:  Biomed Opt Express       Date:  2019-08-27       Impact factor: 3.732

5.  Noninvasive Glucose Monitoring: In God We Trust-All Others Bring Data.

Authors:  David C Klonoff; Kevin T Nguyen; Nicole Y Xu; Mark A Arnold
Journal:  J Diabetes Sci Technol       Date:  2021-10-21

6.  Refractive properties of the healthy human eye during acute hyperglycemia.

Authors:  Nanouk G M Wiemer; Elisabeth M W Eekhoff; Suat Simsek; Robert J Heine; Peter J Ringens; Bettine C P Polak; Michiel Dubbelman
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-04-04       Impact factor: 3.117

7.  Study of Two Constraints Impacting Measurements of Human Glycemia Using a Microwave Sensor.

Authors:  Mohamed Amine Zidane; Hichem Amar; Amar Rouane
Journal:  Biosensors (Basel)       Date:  2021-03-15
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.