Literature DB >> 19840142

Cannulation and vascular access-related complications in hemodialysis: factors determining successful cannulation.

Magda M van Loon1, Alfons G H Kessels, Frank M Van der Sande, Jan H M Tordoir.   

Abstract

Little is known about cannulation of the vascular access (VA), such as the number of successful cannulation procedures, frequency of complications caused by cannulation, and VA failure. Incident patients were followed for 6 months, from the first successful cannulation with 2 needles--both used for the hemodialysis treatment. Data included patient characteristics, comorbidities, and medication. Vascular access characteristics included: type of VA and location, vein diameter assessed by Duplex ultrasound, length of the cannulation route, and maturation period. Longitudinal data were collected by dialysis nurses, using identical questionnaires, and a standardized method to register data from each dialysis session. Among 10 Dutch dialysis facilities, clinical data from 120 patients were collected from June 2005 to March 2007. The use of autogenous arteriovenous fistulae (P<0.001) and limited length of the cannulation route (P<0.003) negatively affect the outcome of cannulation and complications such as use of single-needle (SN) dialysis and central vein catheters (CVC). Previous use of CVC and SN hemodialysis were significant predictors for VA failure (P<0.0001). The present study demonstrated that during the first 6 months of a newly placed VA, a huge number of cannulation-related complications such as miscannulation, use of CVC, and SN dialysis are encountered. Despite the fact that guidelines recommended the arteriovenous fistulae as the preferred VA, cannulation-related complications can lead to increased morbidity. The length of the cannulation route positively correlates with successful cannulation. Therefore, adjusted cannulation techniques might be indicated to improve VA outcome.

Entities:  

Mesh:

Year:  2009        PMID: 19840142     DOI: 10.1111/j.1542-4758.2009.00382.x

Source DB:  PubMed          Journal:  Hemodial Int        ISSN: 1492-7535            Impact factor:   1.812


  13 in total

1.  Fistula first: recent progress and ongoing challenges.

Authors:  Michael Allon
Journal:  Am J Kidney Dis       Date:  2011-01       Impact factor: 8.860

2.  Achieving the goal of the Fistula First breakthrough initiative for prevalent maintenance hemodialysis patients.

Authors:  Janet R Lynch; Haimanot Wasse; Nancy C Armistead; William M McClellan
Journal:  Am J Kidney Dis       Date:  2010-11-30       Impact factor: 8.860

Review 3.  Single needle hemodialysis: is the past the future?

Authors:  Raymond Vanholder
Journal:  J Nephrol       Date:  2019-09-19       Impact factor: 3.902

4.  Should Buttonhole Cannulation of Arteriovenous Fistulas Be Used? Moderator Commentary.

Authors:  Anil K Agarwal
Journal:  Kidney360       Date:  2020-04-14

5.  Effectiveness of a New Single-Needle Single-Pump Dialysis System with Simultaneous Monitoring of Dialysis Dose.

Authors:  Wolfgang Bieser; Markus Welsch; Marten Jakob; Jörn Meibaum; David A Rodriguez; Henrik Wolff; Daniele Marcelli; Claudia Barth
Journal:  Artif Organs       Date:  2018-04-16       Impact factor: 3.094

6.  Variables associated with successful vascular access cannulation in hemodialysis patients: a prospective cohort study.

Authors:  Linda L Coventry; Jon M Hosking; Doris T Chan; Evelyn Coral; Wai H Lim; Amanda Towell-Barnard; Diane E Twigg; Claire M Rickard
Journal:  BMC Nephrol       Date:  2019-05-31       Impact factor: 2.388

7.  Factors associated with complications of vascular access site in hemodialysis patients in Isfahan Aliasghar hospital.

Authors:  Mohsen Adib-Hajbagheri; Narjes Molavizadeh; Negin Masoodi Alavi; Mahmood Hosseiny Mosa Abadi
Journal:  Iran J Nurs Midwifery Res       Date:  2014-03

8.  Is It Time to Abandon Buttonhole Cannulation of Arteriovenous Fistulas?

Authors:  Michael Allon
Journal:  Kidney Med       Date:  2019-09-12

9.  Randomized pilot study to compare metal needles versus plastic cannulae in the development of complications in hemodialysis access.

Authors:  Rosa M Marticorena; Niki Dacouris; Sandra M Donnelly
Journal:  J Vasc Access       Date:  2018-02-28       Impact factor: 2.283

10.  Vascular access cannulation in hemodialysis patients: technical approach.

Authors:  Manuel Carlos Martins Castro; Francisca Tokiko Yanagida Carlquist; Celina de Fátima Silva; Magdaleni Xagoraris; Jerônimo Ruiz Centeno; José Adilson Camargo de Souza
Journal:  J Bras Nefrol       Date:  2019-12-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.