Literature DB >> 19837549

Low incidence of postoperative complications due to pin placement in computer-navigated total knee arthroplasty.

Richard F Owens1, Michael L Swank.   

Abstract

Computer-navigated joint arthroplasty surgery using optical tracking systems requires arrays fixated to bone via pins. Reports of fractures at pin sites have raised concern about safety. We reviewed the postoperative complications occurring in a single-surgeon series of 984 consecutive primary total knee arthroplasties. All pins were placed unicortically and connected by a dual pin array. Femoral pins were placed into the medial epicondyle, and tibial pins were placed in the shaft 10 cm inferior to the joint line. There were no fractures. Seventeen (1.7%) patients had minor pin-related complications. Twelve patients had a superficial infection around the tibial pin sites, which resolved with antibiotics. None of the infections required readmission or reoperation. We believe pin placement to be safe and effective with proper technique.
Copyright © 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 19837549     DOI: 10.1016/j.arth.2009.07.025

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  7 in total

1.  Radiological outcomes of pinless navigation in total knee arthroplasty: a randomized controlled trial.

Authors:  Jerry Yongqiang Chen; Pak Lin Chin; Zongxian Li; Andy Khye Soon Yew; Darren Keng Jin Tay; Shi-Lu Chia; Ngai Nung Lo; Seng Jin Yeo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-08-14       Impact factor: 4.342

2.  Is sequential bilateral robotic total knee arthroplasty a safe procedure? A matched comparative pilot study.

Authors:  Cécile Batailler; Mike B Anderson; Xavier Flecher; Matthieu Ollivier; Sébastien Parratte
Journal:  Arch Orthop Trauma Surg       Date:  2022-05-10       Impact factor: 3.067

3.  Less outliers in pinless navigation compared with conventional surgery in total knee arthroplasty.

Authors:  Jerry Yongqiang Chen; Pak Lin Chin; Darren Keng Jin Tay; Shi-Lu Chia; Ngai Nung Lo; Seng Jin Yeo
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-03-02       Impact factor: 4.342

4.  Accuracy of patient specific cutting blocks in total knee arthroplasty.

Authors:  Naeder Helmy; Mai Lan Dao Trong; Stefanie P Kühnel
Journal:  Biomed Res Int       Date:  2014-08-31       Impact factor: 3.411

5.  Do bicortical diaphyseal array pins create the risk of periprosthetic fracture in robotic-assisted knee arthroplasties?

Authors:  Andrew G Yun; Marilena Qutami; Kory B Dylan Pasko
Journal:  Arthroplasty       Date:  2021-07-05

6.  Periprosthetic Fracture through a Unicortical Tracking Pin Site after Computer Navigated Total Knee Replacement.

Authors:  Matt Blue; Christian Douthit; Joel Dennison; Cyrus Caroom; Mark Jenkins
Journal:  Case Rep Orthop       Date:  2018-09-16

7.  Robotic- and orthosensor-assisted versus manual (ROAM) total knee replacement: a study protocol for a randomised controlled trial.

Authors:  Nick D Clement; Michelle Bardgett; Steven Galloway; Y Jenny Baron; Karen Smith; David J Weir; David J Deehan
Journal:  Trials       Date:  2022-01-22       Impact factor: 2.279

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.