Literature DB >> 19836563

Optical fiber biosensor coupled to chromatographic separation for screening of dopamine, norepinephrine and epinephrine in human urine and plasma.

Lurdes I B Silva1, Filipe D P Ferreira, Ana C Freitas, Teresa A P Rocha-Santos, A C Duarte.   

Abstract

An optical fiber biosensor has been developed for the determination of catecholamines (dopamine, norepinephrine and epinephrine) based on the recognition capacity of the enzyme laccase. In this study, a glass tube constituted by a fused silica fiber coated with a film of polystyrene/divinylbenzene resin (PS/DVB) was used for catecholamines separation. Firstly, the analyzer was tested for calibration and its analytical performance for catecholamines detection was compared with a classical analytical method, namely high performance liquid chromatography-electrochemical detector (HPLC-ED). The developed analytical device shows a high potential for catecholamines quantification with a detection limit of 2.1, 2.6 and 3.4 pg mL(-1) for dopamine, norepinephrine and epinephrine, respectively. The analytical sensitivity, inferred from the slope of the calibration curves established for a range of concentrations between 5 and 125 pg mL(-1), was found to be 0.344, 0.252 and 0.140 dB/pg mL(-1) for dopamine, norepinephrine and epinephrine, respectively. Furthermore, catecholamines speciation with the PS/DVB fiber was completely achieved in 3 min. The analytical performance of the reported sensor was also evaluated and found adequate for catecholamines determination in human urine and plasma samples.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19836563     DOI: 10.1016/j.talanta.2009.08.003

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  5 in total

1.  Surface plasmon resonance fiber sensor for real-time and label-free monitoring of cellular behavior.

Authors:  Yanina Shevchenko; Gulden Camci-Unal; Davide F Cuttica; Mehmet R Dokmeci; Jacques Albert; Ali Khademhosseini
Journal:  Biosens Bioelectron       Date:  2014-01-18       Impact factor: 10.618

2.  A rapid method for the determination of dopamine in porcine muscle by pre-column derivatization and HPLC with fluorescence detection.

Authors:  Hong-Xia Zhao; Hui Mu; Yan-Hong Bai; Hu Yu; Ying-Mei Hu
Journal:  J Pharm Anal       Date:  2011-07-22

3.  Electrochemically synthesized highly crystalline nitrogen doped graphene nanosheets with exceptional biocompatibility.

Authors:  Deepa Suhag; Arun Kumar Sharma; Satyendra K Rajput; Gajender Saini; Sandip Chakrabarti; Monalisa Mukherjee
Journal:  Sci Rep       Date:  2017-04-03       Impact factor: 4.379

Review 4.  A Fluorescent Biosensors for Detection Vital Body Fluids' Agents.

Authors:  Witold Nawrot; Kamila Drzozga; Sylwia Baluta; Joanna Cabaj; Karol Malecha
Journal:  Sensors (Basel)       Date:  2018-07-24       Impact factor: 3.576

5.  Graphene Oxide Bulk-Modified Screen-Printed Electrodes Provide Beneficial Electroanalytical Sensing Capabilities.

Authors:  Samuel J Rowley-Neale; Dale A C Brownson; Graham Smith; Craig E Banks
Journal:  Biosensors (Basel)       Date:  2020-03-19
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.