Literature DB >> 19833534

Inadequate visualization and reporting of ventricular function from transthoracic echocardiography after cardiac surgery.

Brigid C Flynn1, Jessica Spellman, Carol Bodian, Vivek K Moitra.   

Abstract

OBJECTIVES: The purpose of this study was to determine the incidence of and risk factors for inadequate reporting of ventricular function from transthoracic echocardiography after cardiac surgery. DESIGN AND
SETTING: A retrospective study of cardiac surgical patients at 1 university hospital. PATIENTS: The first 300 consecutive patients who had transthoracic echocardiogram within the first 7 days after cardiac surgery.
INTERVENTIONS: None.
MEASUREMENTS AND MAIN RESULTS: The primary outcomes for this study were inadequate visualization of the left ventricle, the right ventricle, or both ventricles. Analysis of data from 300 patients identified inadequate imaging of the left ventricle in 50 (17%) cases, inadequate imaging of the right ventricle in 112 (37%) cases, inadequate imaging of both ventricles in 37 (12%) cases, and inadequate imaging of either the left or right ventricle in 125 (42%) cases. Increasing age, earlier postoperative day, male sex, and median sternotomy were associated with inadequate imaging.
CONCLUSIONS: Transthoracic imaging is often inadequate in patients who have undergone recent cardiac surgery. Patient and surgical characteristics influence reporting of right and left ventricular function. Copyright (c) 2010 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2009        PMID: 19833534     DOI: 10.1053/j.jvca.2009.07.019

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  4 in total

1.  Improved Visualization in Difficult-to-Image Stress Echocardiography Patients Using Real-Time Harmonic Spatial Coherence Imaging.

Authors:  Dongwoon Hyun; Anna Lisa C Crowley; Melissa LeFevre; Jayne Cleve; Jarrett Rosenberg; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-12-10       Impact factor: 2.725

2.  Efficacy of transthoracic echocardiography for diagnosing heart failure in septic shock.

Authors:  Anne-Sophie Beraud; Cristina Vazquez Guillamet; Jessie L Hammes; Lina Meng; Mark R Nicolls; Joe L Hsu
Journal:  Am J Med Sci       Date:  2014-04       Impact factor: 2.378

3.  Spatiotemporal Coherence to Quantify Sources of Image Degradation in Ultrasonic Imaging.

Authors:  Emelina P Vienneau; Kathryn A Ozgun; Brett C Byram
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2022-03-30       Impact factor: 3.267

4.  A model and regularization scheme for ultrasonic beamforming clutter reduction.

Authors:  Brett Byram; Kazuyuki Dei; Jaime Tierney; Douglas Dumont
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-11       Impact factor: 2.725

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.