Vincenzo Leone1, Daniele Misuri, Nico Console.
Abstract
We report a case of a radial artery pseudoaneurysm complicating a single arterial puncture for blood-gas analysis that was treated with excision of pseudoaneurysm and suture of the defect of wall of radial artery. The puncture for continuous blood pressure monitoring and serial blood gas analysis have been reported in critically ill patients, but, to the best of our knowledge, there are no cases reported of pseudoaneurysm after a single arterial puncture for blood-gas analysis. In the reported case we think that the main cause of the pseudoaneurysm onset was an incorrect compression and/or a too much short time of compression of the radial artery after the puncture. Minor sequelae and rare complications may be minimized by careful attention to detail in the performance of such procedures and care of the patient also after a single arterial puncture.Entities:
Year: 2009 PMID: 19829877 PMCID: PMC2740058 DOI: 10.4076/1757-1626-2-6890
Source DB: PubMed Journal: Cases J ISSN: 1757-1626
Figure 1.Pulsatile 3 cm mass over the left volar wrist.
Figure 2.Isolated pseudoaneurysm.
Figure 3.The ends of radial artery were identified and oversaw.