Literature DB >> 19828592

A randomized clinical trial of thermoplastic retainer wear.

E Thickett1, S Power.   

Abstract

The purpose of this study was to determine whether thermoplastic retainers need to be worn full-time for a limited period or whether part-time wear from the outset is adequate to maintain tooth position, arch form, and occlusion. This study was a randomized clinical trail, conducted in a district general hospital. Sixty-two participants were enrolled in the study. Group 1, full-time wear, consisted of 30 patients (12 males and 18 females, aged 13.6 +/- 1.5 years) and group 2, part-time wear, 32 patients (14 males and 18 females, aged 13.8 +/- 1.5 years). Each patient was assigned to one of the groups by random number generation. Clinical records in the form of study models were taken at the start of active treatment (T1), at debond (T2), 6 months into the retention phase (T3), and 1 year post-debond (T4). The irregularity index, intercanine width, intermolar width, arch length, overbite, overjet, and Peer Assessment Rating (PAR) scores were measured on study models using digital callipers. A Mann-Whitney test was used to evaluate the treatment changes within each group. The only statistically significant difference was found to be at T3 and T4 for overbite (P = 0.05 and P = 0.02, respectively). PAR scoring showed more variable changes in group 2. There was good correlation for the measurement method. There was no statistical difference for the two groups for overjet, arch length, intermolar width, intercanine width, and irregularity index at any time point.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19828592     DOI: 10.1093/ejo/cjp061

Source DB:  PubMed          Journal:  Eur J Orthod        ISSN: 0141-5387            Impact factor:   3.075


  14 in total

1.  Performance of clear vacuum-formed thermoplastic retainers depending on retention protocol: a systematic review.

Authors:  Eleftherios G Kaklamanos; Maria Kourakou; Dimitrios Kloukos; Ioannis Doulis; Smaragda Kavvadia
Journal:  Odontology       Date:  2016-06-06       Impact factor: 2.634

2.  A multicentre audit of GDPs knowledge of orthodontic retention.

Authors:  S Kotecha; S Gale; L Khamashta-Ledezma; J Scott; M Seedat; M Storey; A Ulhaq; J Scholey
Journal:  Br Dent J       Date:  2015-06-12       Impact factor: 1.626

Review 3.  Retention in orthodontics.

Authors:  C D Johnston; S J Littlewood
Journal:  Br Dent J       Date:  2015-02-16       Impact factor: 1.626

4.  Evaluation of relapse with thermoplastic retainers equipped with microsensors.

Authors:  Sait İshakoğlu; Serpil Çokakoğlu
Journal:  Angle Orthod       Date:  2022-05-01       Impact factor: 2.684

5.  Intra-examiner and Inter-examiner Reproducibility in Irregularity Index Measurements.

Authors:  Ersat Cem İrezli; Mücahid Faik Şahin; Rana Demir; Aslı Baysal
Journal:  Turk J Orthod       Date:  2019-09-01

6.  Survey on Retention Protocols Among Turkish Orthodontists.

Authors:  Aylin Paşaoğlu; Işıl Aras; Ali Mert; Aynur Aras
Journal:  Turk J Orthod       Date:  2016-09-01

7.  Anterior tooth alignment: A comparison of orthodontic retention regimens 5 years posttreatment.

Authors:  Ragnar Bjering; Kari Birkeland; Vaska Vandevska-Radunovic
Journal:  Angle Orthod       Date:  2014-08-20       Impact factor: 2.079

8.  Mandibular arch orthodontic treatment stability using passive self-ligating and conventional systems in adults: A randomized controlled trial.

Authors:  Norma Ab Rahman; Mang Chek Wey; Siti Adibah Othman
Journal:  Korean J Orthod       Date:  2016-12-19       Impact factor: 1.372

Review 9.  Retention procedures for stabilising tooth position after treatment with orthodontic braces.

Authors:  Simon J Littlewood; Declan T Millett; Bridget Doubleday; David R Bearn; Helen V Worthington
Journal:  Cochrane Database Syst Rev       Date:  2016-01-29

Review 10.  The effects of fixed and removable orthodontic retainers: a systematic review.

Authors:  Dalya Al-Moghrabi; Nikolaos Pandis; Padhraig S Fleming
Journal:  Prog Orthod       Date:  2016-07-26       Impact factor: 2.750

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.