Literature DB >> 19826391

Glaucoma aqueous drainage device erosion repair with buccal mucous membrane grafts.

Dan B Rootman1, Graham E Trope, David S Rootman.   

Abstract

PURPOSE: Glaucoma aqueous drainage devices are important and effective in the management of recalcitrant glaucoma. One complication of this procedure is erosion and exposure of the tube or plate. Strategies to re-cover glaucoma aqueous drainage devices in such cases have met with variable success. The majority of these interventions use conjunctiva for superficial coverage. However, conjunctiva can be in limited supply, and subject to reerosion.
METHODS: In this report, we discuss the use of oral buccal mucous membrane in combination with a lamellar corneal patch graft for repair of 3 exposed tubes, 2 plates, and a pars plana clip. Mean time to exposure was 4.8 years. Five eyes from 4 patients are presented and the surgical technique is described.
RESULTS: Buccal membrane repairs were considered a surgical success in 5 out of 6 cases (83%) with mean follow-up of 1.5 years.
CONCLUSIONS: We advocate the use of buccal membrane in the repair of glaucoma aqueous drainage device tube/plate erosions in patients for whom local conjunctiva is of variable quality or limited supply. Advantages of this procedure and tissue option are discussed.

Entities:  

Mesh:

Year:  2009        PMID: 19826391     DOI: 10.1097/IJG.0b013e318193c472

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  5 in total

1.  Tube Exposure Repair.

Authors:  Stirbu Oana; Jorge Vila
Journal:  J Curr Glaucoma Pract       Date:  2012-10-16

2.  The best thickness of cornea graft from SMILE surgery as patch graft in glaucoma drainage implant surgery.

Authors:  Yuhong Wang; Jinkun Liu; Weiyi Huang; Yazhang Xu; Meizhu Cheng; Zhengwei Shen
Journal:  Medicine (Baltimore)       Date:  2021-05-21       Impact factor: 1.817

3.  Partial thickness corneal tissue as a patch graft material for prevention of glaucoma drainage device exposure.

Authors:  Oriel Spierer; Michael Waisbourd; Yitzhak Golan; Hadas Newman; Rony Rachmiel
Journal:  BMC Ophthalmol       Date:  2016-02-27       Impact factor: 2.209

4.  Risk factors for tube exposure as a late complication of glaucoma drainage implant surgery.

Authors:  Meenakshi Chaku; Peter A Netland; Kyoko Ishida; Douglas J Rhee
Journal:  Clin Ophthalmol       Date:  2016-03-30

5.  Assessing full thickness oral mucosal grafting: complications and postoperative outcomes in a broad collective of patients.

Authors:  Daniel Pilger; Christoph von Sonnleithner; Eckart Bertelmann
Journal:  BMJ Open Ophthalmol       Date:  2020-02-10
  5 in total