Abstract
AIM: To evaluate the effectiveness of three-dimensional endoanal ultrasound (3D-EAUS) in the assessment of anal fistulae with and without H(2)O(2) enhancement. METHODS: Sixty-one patients (37 males, aged 17-74 years) with anal fistulae, which were not simple low types, were evaluated by physical examination and 3D-EAUS with and without enhancement. Fistula classification was determined with each modality and compared to operative findings as the reference standard. RESULTS: The accuracy of 3D-EAUS was significantly higher than that of physical examination in detecting the primary tract (84.4% vs 68.7%, P = 0.037) and secondary extension (81.8% vs 62.1%, P = 0.01) and localizing the internal opening (84.2% vs 59.7%, P = 0.004). A contrast study with H(2)O(2) detected several more fistula components including two primary suprasphincteric fistula tracks and one supralevator secondary extension, which were not detected on non-contrast study. However, there was no significant difference in accuracy between 3D-EAUS and H(2)O(2)-enhanced 3D-EAUS with respect to classification of the primary tract (84.4% vs 89.1%, P = 0.435) or secondary extension (81.8% vs 86.4%, P = 0.435) or localization of the internal opening (84.2% vs 89.5%, P = 0.406). CONCLUSION: 3D-EAUS was highly reliable in the diagnosis of an anal fistula. H(2)O(2) enhancement was helpful at times and selective use in difficult cases may be economical and reliable.
AIM: To evaluate the effectiveness of three-dimensional endoanal ultrasound (3D-EAUS) in the assessment of anal fistulae with and without H(2)O(2) enhancement. METHODS: Sixty-one patients (37 males, aged 17-74 years) with anal fistulae, which were not simple low types, were evaluated by physical examination and 3D-EAUS with and without enhancement. Fistula classification was determined with each modality and compared to operative findings as the reference standard. RESULTS: The accuracy of 3D-EAUS was significantly higher than that of physical examination in detecting the primary tract (84.4% vs 68.7%, P = 0.037) and secondary extension (81.8% vs 62.1%, P = 0.01) and localizing the internal opening (84.2% vs 59.7%, P = 0.004). A contrast study with H(2)O(2) detected several more fistula components including two primary suprasphincteric fistula tracks and one supralevator secondary extension, which were not detected on non-contrast study. However, there was no significant difference in accuracy between 3D-EAUS and H(2)O(2)-enhanced 3D-EAUS with respect to classification of the primary tract (84.4% vs 89.1%, P = 0.435) or secondary extension (81.8% vs 86.4%, P = 0.435) or localization of the internal opening (84.2% vs 89.5%, P = 0.406). CONCLUSION: 3D-EAUS was highly reliable in the diagnosis of an anal fistula. H(2)O(2) enhancement was helpful at times and selective use in difficult cases may be economical and reliable.
Authors: R L West; D D E Zimmerman; S Dwarkasing; S M Hussain; W C J Hop; W R Schouten; E J Kuipers; R J F Felt-Bersma Journal: Dis Colon Rectum Date: 2003-10 Impact factor: 4.585
Authors: Gordon N Buchanan; Steve Halligan; Clive I Bartram; Andrew B Williams; Danilo Tarroni; C Richard G Cohen Journal: Radiology Date: 2004-10-21 Impact factor: 11.105
Authors: M Plaikner; A Loizides; S Peer; F Aigner; D Pecival; A Zbar; C Kremser; H Gruber Journal: Tech Coloproctol Date: 2013-05-17 Impact factor: 3.781