Literature DB >> 19822984

Dimensional change measurements of conventional and flowable composite resins using a laser displacement sensor.

Taira Miyasaka1, Hiroyuki Okamura.   

Abstract

The polymerization shrinkage values of commercial flowable and conventional composites were measured with a newly developed laser displacement sensor. Compressive strength and filler content were also measured. Compared to conventional composites, the flowable composites required a longer time - not exceeding 4 minutes - to reach a constant polymerization shrinkage rate. In terms of shrinkage ratio, it was less than 1.5% for conventional composites at 90 minutes, which was lower than that of flowable composites, i.e. more than 2.0%. The compressive strength of conventional composites was higher than that of flowable composites. A highly significant correlation between filler content and polymerization shrinkage at 90 minutes was observed, and polymerization shrinkage tended to decrease as filler content increased. In light of the results obtained in this study, the newly developed displacement meter with a laser displacement sensor proved to be effective for in-depth investigation of the polymerization shrinkage of dental composites.

Mesh:

Substances:

Year:  2009        PMID: 19822984     DOI: 10.4012/dmj.28.544

Source DB:  PubMed          Journal:  Dent Mater J        ISSN: 0287-4547            Impact factor:   2.102


  5 in total

1.  Randomized controlled clinical trial of a highly filled flowable composite in non-carious cervical lesions: 3-year results.

Authors:  Haiying Zhang; Luxuan Wang; Lin Hua; Rui Guan; Benxiang Hou
Journal:  Clin Oral Investig       Date:  2021-04-02       Impact factor: 3.573

2.  How light attenuation and filler content affect the microhardness and polymerization shrinkage and translucency of bulk-fill composites?

Authors:  Sung-Ae Son; Jeong-Kil Park; Deog-Gyu Seo; Ching-Chang Ko; Yong Hoon Kwon
Journal:  Clin Oral Investig       Date:  2016-07-31       Impact factor: 3.573

3.  An in vitro microleakage study of class V cavities restored with a new self-adhesive flowable composite resin versus different flowable materials.

Authors:  Mostafa Sadeghi
Journal:  Dent Res J (Isfahan)       Date:  2012-07

4.  Does the use of a novel self-adhesive flowable composite reduce nanoleakage?

Authors:  Abeer Abo El Naga; Mohammed Yousef; Rasha Ramadan; Sherif Fayez Bahgat; Lana Alshawwa
Journal:  Clin Cosmet Investig Dent       Date:  2015-03-27

5.  A comparative evaluation of microleakage in class v composite restorations.

Authors:  Sujatha Gopal Sooraparaju; Pavan Kumar Kanumuru; Surya Kumari Nujella; Karthik Roy Konda; K Bala Kasi Reddy; Sivaram Penigalapati
Journal:  Int J Dent       Date:  2014-12-25
  5 in total