Literature DB >> 19820488

Comparison study of different bowel preparation regimens and different fecal-tagging agents on tagging efficacy, patients' compliance, and diagnostic performance of computed tomographic colonography: preliminary study.

Soon Ho Yoon1, Se Hyung Kim, Sang Gyun Kim, Soo Jin Kim, Jeong Min Lee, Jae Young Lee, Joon Koo Han, Byung Ihn Choi.   

Abstract

PURPOSE: To compare and find the optimal combination of bowel preparation regimens and different concentrations of barium-based fecal-tagging agents on computed tomographic colonography in terms of tagging efficacy, patients' compliance, and diagnostic performance.
MATERIALS AND METHODS: Sixty-nine consecutive patients were prospectively enrolled and randomly divided into 4 groups according to a combination of bowel preparation regimens (sodium phosphate [Colclean] vs magnesium citrate [LoSoPrep]) and different concentrations of barium-based fecal-tagging agents (Tagitol V [thick, 40% wt/vol] 60 mL vs EasyCT [thin, 4.6% wt/vol] 600 mL). Patients who received Colclean and EasyCT were designated as group 1; Colclean and Tagitol V as group 2; LoSoPrep and EasyCT, group 3; and LoSoPrep and Tagitol V, group 4. For objective analysis, the volume of tagged feces and fluid was semiautomatically calculated using a threshold of 150 Hounsfield units. The volume of untagged feces and fluid was also calculated using the seeded region-growing method. The tagging efficacy was then calculated and compared using the analysis of variance test. For subjective analysis, 2 radiologists visually determined the overall tagging efficacy on a segmental basis. The numbers of homogeneously tagged, heterogeneously tagged, heterogeneously untagged, and homogeneously untagged feces greater than or equal to 6 mm and fluid were counted in each segment. The rates of homogeneously tagged stool and fluid were compared between the groups using the chi test. Patients' compliance for taking the regimens was recorded and compared using the Kruskal-Wallis test. Per-polyp and per-patient sensitivity for polyps greater than or equal to 6 mm were analyzed and compared using the chi or Fisher exact test.
RESULTS: Objective analysis showed that tagging efficacy was significantly lower in group 1 than in the other 3 groups. In a subjective analysis, overall tagging efficacy was significantly higher in group 4 than in the other groups. The rate of homogeneously tagged fluid was significantly higher in group 4 than in the other groups. The rate of homogeneously tagged feces was significantly higher in the thick barium group than in the thin barium group. Patients' compliance was significantly worse in group 1 than in the other 3 groups. Per-polyp and per-patient sensitivities for polyps greater than or equal to 6 mm were not significantly different among all groups. However, per-patient specificity for lesions greater than or equal to 10 mm was significantly lower in group 2 than in the other groups.
CONCLUSIONS: With better tagging efficacy and compliance while maintaining comparable diagnostic performance, it is our belief that the best combination of bowel preparation and fecal-tagging regimen is a combination of magnesium citrate and a high concentration of a barium tagging agent.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19820488     DOI: 10.1097/RCT.0b013e3181926570

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  4 in total

Review 1.  Colorectal cancer: CT colonography and colonoscopy for detection--systematic review and meta-analysis.

Authors:  Perry J Pickhardt; Cesare Hassan; Steve Halligan; Riccardo Marmo
Journal:  Radiology       Date:  2011-03-17       Impact factor: 11.105

2.  Reduced cathartic bowel preparation for CT colonography: prospective comparison of 2-L polyethylene glycol and magnesium citrate.

Authors:  Alexander W Keedy; Judy Yee; Rizwan Aslam; Stefanie Weinstein; Luis A Landeras; Janak N Shah; Kenneth R McQuaid; Benjamin M Yeh
Journal:  Radiology       Date:  2011-08-24       Impact factor: 11.105

3.  Electronic cleansing for CT colonography: does it help CAD software performance in a high-risk population for colorectal cancer?

Authors:  Jae Yeon Wi; Se Hyung Kim; Jae Young Lee; Sang Gyun Kim; Joon Koo Han; Byung Ihn Choi
Journal:  Eur Radiol       Date:  2010-03-23       Impact factor: 5.315

4.  Pilot study on efficacy of reduced cathartic bowel preparation with polyethylene glycol and bisacodyl.

Authors:  Zhi-Yuan Chen; He-Song Shen; Ming-Yue Luo; Chai-Jie Duan; Wen-Li Cai; Hong-Bing Lu; Guo-Peng Zhang; Yang Liu; Jerome Z Liang
Journal:  World J Gastroenterol       Date:  2013-01-28       Impact factor: 5.742

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.