Literature DB >> 19808478

Prediction of ventricular tachyarrhythmias by intracardiac repolarization variability analysis.

Larisa G Tereshchenko1, Barry J Fetics, Peter P Domitrovich, Bruce D Lindsay, Ronald D Berger.   

Abstract

BACKGROUND: Arrhythmic sudden cardiac death (SCD) is generally mediated by ventricular fibrillation (VF) or fast ventricular tachycardia (FVT). We studied the predictive value of temporal QT variability detected from various sources of cardiac electric signal: surface ECG, far-field (FF), and near-field (NF) intracardiac electrograms (EGMs) in patients with implantable cardioverter-defibrillators (ICDs). METHODS AND
RESULTS: Surface ECG and FF and NF intracardiac EGMs were simultaneously recorded at rest (mean heart rate, 74+/-15 bpm) for 4.5+/-1.3 minutes in 298 patients (mean age, 59+/-14; 216 male [73%]) with structural heart disease and an implanted Medtronic ICD for primary (231 patients, 78%) or secondary (67 patients, 22%) prevention of SCD. During mean follow-up of 16+/-8 months, 52 (13.1% per person-year of follow-up) patients sustained VT/VF and received appropriate ICD therapies, but only 19 (4.8% per person-year of follow-up) patients sustained FVT/VF with cycle length <or=240 ms. The Kaplan-Meier survival analysis showed that the highest QT variability index (QTVI) quartile from all cardiac sources (surface ECG; NF and FF EGMs) is associated with event-free survival (P=0.038 for ECG; P=0.024 for FF EGM; P=0.012 for NF EGM). QTVI was a predictor of all VT/VF events and FVT/VF in the multivariate Cox model (including ischemic or nonischemic cardiomyopathy, history of revascularization procedures, LVEF, New York Heart Association class). Strong significant correlation among QTVI determined from all 3 sources was found.
CONCLUSIONS: Repolarization lability is present throughout the ventricular myocardium. Increased intracardiac QT variability predicts VT/VF events in patients with structural heart disease.

Entities:  

Mesh:

Year:  2009        PMID: 19808478     DOI: 10.1161/CIRCEP.108.829440

Source DB:  PubMed          Journal:  Circ Arrhythm Electrophysiol        ISSN: 1941-3084


  22 in total

1.  Predictive value of beat-to-beat QT variability index across the continuum of left ventricular dysfunction: competing risks of noncardiac or cardiovascular death and sudden or nonsudden cardiac death.

Authors:  Larisa G Tereshchenko; Iwona Cygankiewicz; Scott McNitt; Rafael Vazquez; Antoni Bayes-Genis; Lichy Han; Sanjoli Sur; Jean-Philippe Couderc; Ronald D Berger; Antoni Bayes de Luna; Wojciech Zareba
Journal:  Circ Arrhythm Electrophysiol       Date:  2012-06-23

Review 2.  Towards a better understanding of QT interval variability.

Authors:  Larisa G Tereshchenko; Ronald D Berger
Journal:  Ther Adv Drug Saf       Date:  2011-12

3.  VV' Alternans Triplets on Near-Field ICD Intracardiac Electrogram is Associated with Mortality.

Authors:  Mathias Baumert; Muammar M Kabir; Khidir Dalouk; Charles A Henrikson; Larisa G Tereshchenko
Journal:  Pacing Clin Electrophysiol       Date:  2015-03-09       Impact factor: 1.976

4.  Beat-to-beat three-dimensional ECG variability predicts ventricular arrhythmia in ICD recipients.

Authors:  Larisa G Tereshchenko; Lichy Han; Alan Cheng; Joseph E Marine; David D Spragg; Sunil Sinha; Darshan Dalal; Hugh Calkins; Gordon F Tomaselli; Ronald D Berger
Journal:  Heart Rhythm       Date:  2010-09-29       Impact factor: 6.343

5.  Arrhythmia risk stratification based on QT interval instability: an intracardiac electrocardiogram study.

Authors:  Xiaozhong Chen; Larisa G Tereshchenko; Ronald D Berger; Natalia A Trayanova
Journal:  Heart Rhythm       Date:  2013-02-13       Impact factor: 6.343

6.  Construction of intracardiac vectorcardiogram from implantable cardioverter-defibrillator intracardiac electrograms.

Authors:  Elyar Ghafoori; Muammar M Kabir; Jian Cao; Alexei Shvilkin; Larisa G Tereshchenko
Journal:  J Electrocardiol       Date:  2015-05-08       Impact factor: 1.438

7.  Incidence of rearrest after return of spontaneous circulation in out-of-hospital cardiac arrest.

Authors:  David D Salcido; Amanda M Stephenson; Joseph P Condle; Clifton W Callaway; James J Menegazzi
Journal:  Prehosp Emerg Care       Date:  2010 Oct-Dec       Impact factor: 3.077

8.  High atrioventricular phase index on near-field intracardiac electrogram is associated with risk of ventricular arrhythmia.

Authors:  Muammar M Kabir; Elyar Ghafoori; Larisa G Tereshchenko
Journal:  J Electrocardiol       Date:  2015-08-05       Impact factor: 1.438

9.  Repolarization lability measured on 10-second ECG by spatial TT' angle: reproducibility and agreement with QT variability.

Authors:  Albert Feeny; Lichy Han; Larisa G Tereshchenko
Journal:  J Electrocardiol       Date:  2014-06-09       Impact factor: 1.438

Review 10.  Ventricular repolarization measures for arrhythmic risk stratification.

Authors:  Francesco Monitillo; Marta Leone; Caterina Rizzo; Andrea Passantino; Massimo Iacoviello
Journal:  World J Cardiol       Date:  2016-01-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.