Literature DB >> 19806266

Is perioperative point-of-care prothrombin time testing accurate compared to the standard laboratory test?

Natalie Urwyler1, Lukas P Staub, Dominik Beran, Marcus Deplazes, Sarah J Lord, Lorenzo Alberio, Lorenz Theiler, Robert Greif.   

Abstract

There is no accepted way of measuring prothrombin time without time loss for patients undergoing major surgery who are at risk of intraoperative dilution and consumption coagulopathy due to bleeding and volume replacement with crystalloids or colloids. Decisions to transfuse fresh frozen plasma and procoagulatory drugs have to rely on clinical judgment in these situations. Point-of-care devices are considerably faster than the standard laboratory methods. In this study we assessed the accuracy of a Point-of-care (PoC) device measuring prothrombin time compared to the standard laboratory method. Patients undergoing major surgery and intensive care unit patients were included. PoC prothrombin time was measured by CoaguChek XS Plus (Roche Diagnostics, Switzerland). PoC and reference tests were performed independently and interpreted under blinded conditions. Using a cut-off prothrombin time of 50%, we calculated diagnostic accuracy measures, plotted a receiver operating characteristic (ROC) curve and tested for equivalence between the two methods. PoC sensitivity and specificity were 95% (95% CI 77%, 100%) and 95% (95% CI 91%, 98%) respectively. The negative likelihood ratio was 0.05 (95% CI 0.01, 0.32). The positive likelihood ratio was 19.57 (95% CI 10.62, 36.06). The area under the ROC curve was 0.988. Equivalence between the two methods was confirmed. CoaguChek XS Plus is a rapid and highly accurate test compared with the reference test. These findings suggest that PoC testing will be useful for monitoring intraoperative prothrombin time when coagulopathy is suspected. It could lead to a more rational use of expensive and limited blood bank resources.

Entities:  

Mesh:

Year:  2009        PMID: 19806266     DOI: 10.1160/TH09-03-0157

Source DB:  PubMed          Journal:  Thromb Haemost        ISSN: 0340-6245            Impact factor:   5.249


  4 in total

1.  Using patient management as a surrogate for patient health outcomes in diagnostic test evaluation.

Authors:  Lukas P Staub; Sarah J Lord; R John Simes; Suzanne Dyer; Nehmat Houssami; Robert Y M Chen; Les Irwig
Journal:  BMC Med Res Methodol       Date:  2012-02-14       Impact factor: 4.615

2.  Comparison of prothrombin time derived from CoaguChek XS and laboratory test according to fibrinogen level.

Authors:  Sue Jung Kim; Eun Young Lee; Rojin Park; Juwon Kim; Jaewoo Song
Journal:  J Clin Lab Anal       Date:  2014-03-28       Impact factor: 2.352

3.  Does point of care prothrombin time measurement reduce the transfusion of fresh frozen plasma in patients undergoing major surgery? The POC-OP randomized-controlled trial.

Authors:  Natalie Urwyler; Sven Trelle; Lorenz Theiler; Peter Jüni; Lukas P Staub; Cedric Luyet; Lorenzo Alberio; Kay Stricker; Robert Greif
Journal:  Trials       Date:  2009-11-23       Impact factor: 2.279

4.  Comparison of international normalized ratio measurement between CoaguChek XS Plus and STA-R coagulation analyzers.

Authors:  Mina Hur; Hanah Kim; Chul Min Park; Antonio La Gioia; Sang-Gyu Choi; Ju-Hee Choi; Hee-Won Moon; Yeo-Min Yun
Journal:  Biomed Res Int       Date:  2012-12-24       Impact factor: 3.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.