Abstract

Whether distal protection devices (DPDs) during percutaneous coronary intervention (PCI) can improve myocardial function in patients with acute myocardial infarction (AMI) is still under debate. Using tissue Doppler imaging (TDI), we evaluate the global and regional left ventricular systolic and diastolic functions in patients with anterior AMI using DPDs compared with conventional PCI. Ninety-six patients with anterior AMI were randomly assigned to either PCI with DPDs (DPD, n = 46) or traditional PCI (control, n = 50) groups. At the 3- and 6-month follow-ups, the DPD group had a higher left ventricular ejection fraction than the control group (51.6 +/- 3.6 vs. 49.3 +/- 5.3% and 53.0 +/- 3.7 vs. 50.8 +/- 5.2%, respectively; both P < 0.05). Moreover, peak systolic (S (a)) and early diastolic (E (a)) mitral annular velocities obtained by TDI were significantly higher in the DPD group than in the control group (S (a): 7.57 +/- 0.53 vs. 7.12 +/- 0.62 cm/s and 7.71 +/- 0.63 vs. 7.32 +/- 0.59 cm/s; E (a): 7.23 +/- 0.78 vs. 6.89 +/- 0.86 cm/s and 7.49 +/- 0.69 vs. 7.04 +/- 0.85 cm/s, respectively; all P < 0.05). However, systolic and diastolic regional myocardial velocities significantly improved in the DPD group from the 1-month follow-up compared with those in the control group (all P < 0.05). Patients who received treatment with DPDs experienced enhanced improvement of cardiac function. Thus, anterior AMI patients can benefit from DPDs during PCI.

Entities:  

Mesh:

Year:  2009        PMID: 19802729     DOI: 10.1007/s10554-009-9513-7

Source DB:  PubMed          Journal:  Int J Cardiovasc Imaging        ISSN: 1569-5794            Impact factor:   2.357


  24 in total

1.  Effect of the PercuSurge GuardWire device on the integrity of microvasculature and clinical outcomes during primary transradial coronary intervention in acute myocardial infarction.

Authors:  Hon-Kan Yip; Chiung-Jen Wu; Hsueh-Wen Chang; Chih-Yuan Fang; Cheng-Hsu Yang; Shyh-Ming Chen; Wei-Chin Hung; Chien-Jen Chen; Cheng-I Cheng; Yuan-Kai Hsieh
Journal:  Am J Cardiol       Date:  2003-12-01       Impact factor: 2.778

2.  Distal embolic protection in patients with acute myocardial infarction: attractive concept but no evidence of benefit.

Authors:  Albert Schömig; Adnan Kastrati
Journal:  JAMA       Date:  2005-03-02       Impact factor: 56.272

3.  Tissue Doppler imaging--a sensible imaging option for the sensitive heart.

Authors:  Yat-Yin Lam; Wei Li; Michael Y Henein
Journal:  Int J Cardiovasc Imaging       Date:  2006-03-31       Impact factor: 2.357

4.  Segmental early relaxation phenomenon as determined by tissue Doppler imaging.

Authors:  Haibin Zhang; Yan Song; Yongsheng Zhu; Hongling Li; Ting Zhu; Yunqiu Qian; Liwen Liu; Jun Zhang; Xiaodong Zhou; Miaozhang Zhu
Journal:  Echocardiography       Date:  2008-03       Impact factor: 1.724

Review 5.  Strain and strain rate deformation parameters: from tissue Doppler to 2D speckle tracking.

Authors:  Harry Pavlopoulos; Petros Nihoyannopoulos
Journal:  Int J Cardiovasc Imaging       Date:  2007-12-12       Impact factor: 2.357

Review 6.  Role of real time three-dimensional echocardiography in heart failure.

Authors:  Ashraf M Anwar; Youssef F M Nosir
Journal:  Echocardiography       Date:  2008-10       Impact factor: 1.724

7.  Distal microcirculatory protection during percutaneous coronary intervention in acute ST-segment elevation myocardial infarction: a randomized controlled trial.

Authors:  Gregg W Stone; John Webb; David A Cox; Bruce R Brodie; Mansoor Qureshi; Anna Kalynych; Mark Turco; Heinz P Schultheiss; Daniel Dulas; Barry D Rutherford; David Antoniucci; Mitchell W Krucoff; Raymond J Gibbons; Denise Jones; Alexandra J Lansky; Roxana Mehran
Journal:  JAMA       Date:  2005-03-02       Impact factor: 56.272

Review 8.  Tissue Doppler imaging a new prognosticator for cardiovascular diseases.

Authors:  Cheuk-Man Yu; John E Sanderson; Thomas H Marwick; Jae K Oh
Journal:  J Am Coll Cardiol       Date:  2007-04-30       Impact factor: 24.094

9.  Distal protection device protects microvascular integrity during primary percutaneous intervention in acute myocardial infarction: a prospective, randomized, multicenter trial.

Authors:  Seung-Jea Tahk; Byoung-Joo Choi; So-Yeon Choi; Myeong-Ho Yoon; Hyeon-Cheol Gwon; Geu-Ru Hong; Young-Jo Kim; Seung-Ho Hur; Kwon-Bae Kim; Bon-Kwon Koo; Seung-Hwan Lee; Junghan Yoon
Journal:  Int J Cardiol       Date:  2007-05-08       Impact factor: 4.164

10.  Effects of a distal protection device during primary stenting in patients with acute anterior myocardial infarction.

Authors:  Tomohiro Nakamura; Norifumi Kubo; Yuichi Seki; Nahoko Ikeda; Takeshi Ishida; Hiroshi Funayama; Shigemasa Hashimoto; Takanori Yasu; Mikihisa Fujii; Masanobu Kawakami; Muneyasu Saito
Journal:  Circ J       Date:  2004-08       Impact factor: 2.993

View more
  2 in total

Review 1.  Cardiovascular imaging 2010 in the International Journal of Cardiovascular Imaging.

Authors:  Ricardo A Costa; Johan H C Reiber; Frank J Rybicki; Paul Schoenhagen; Arthur A Stillman; Johan de Sutter; Nico R L van de Veire; Ernst E van der Wall
Journal:  Int J Cardiovasc Imaging       Date:  2011-02-24       Impact factor: 2.357

Review 2.  Systematic review: comparative effectiveness of adjunctive devices in patients with ST-segment elevation myocardial infarction undergoing percutaneous coronary intervention of native vessels.

Authors:  Diana M Sobieraj; C Michael White; Jeffrey Kluger; Vanita Tongbram; Jennifer Colby; Wendy T Chen; Sagar S Makanji; Soyon Lee; Ajibade Ashaye; Craig I Coleman
Journal:  BMC Cardiovasc Disord       Date:  2011-12-20       Impact factor: 2.298

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.