Literature DB >> 15277736

Effects of a distal protection device during primary stenting in patients with acute anterior myocardial infarction.

Tomohiro Nakamura1, Norifumi Kubo, Yuichi Seki, Nahoko Ikeda, Takeshi Ishida, Hiroshi Funayama, Shigemasa Hashimoto, Takanori Yasu, Mikihisa Fujii, Masanobu Kawakami, Muneyasu Saito.   

Abstract

BACKGROUND: The angiographic no-reflow phenomenon is an adverse prognostic factor in patients with acute myocardial infarction (AMI). The aim of the present study was to evaluate the effects of an occlusive balloon type distal protection device (PercuSurge GuardWire: GW) during primary stenting in patients with anterior AMI. METHODS AND
RESULTS: The GW group included 42 patients treated by primary stenting with GW protection and the control group included 30 patients treated by primary stenting after thrombectomy without distal protection. Left ventricular (LV) function was measured and compared by left ventriculography obtained soon after percutaneous coronary intervention (PCI) and 3 weeks after onset. The corrected TIMI frame count values were lower in the GW group than in the control group (27.5+/-2.3 vs 35.1 +/-2.5, p=0.030). The number of patients with myocardial blush grade 3 after PCI was higher in the GW group than in the control group (45.7 vs 20.0%, p=0.029). Peak concentration of creatine kinase myocardial fraction was lower in the GW group than in the control group (326.6+/-41.5 vs 454.9+/-46.2 mg/dl, p=0.043). GW patients showed greater improvement at 3 weeks after PCI in terms of LV ejection fraction (+4.6+/-1.2 vs -1.1+/-1.5, p=0.004), LV end-systolic volume index (+0.5+/-2.4 vs +9.0+/-2.7, p=0.023), and regional wall motion abnormalities (-2.03+/-0.14 vs -2.51+/-0.14, p=0.018).
CONCLUSION: Primary stenting with GW protection can restore epicardial coronary flow and myocardial perfusion, and also preserve LV function in anterior AMI.

Entities:  

Mesh:

Year:  2004        PMID: 15277736     DOI: 10.1253/circj.68.763

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  3 in total

1.  Effect of a distal protection device on epicardial blood flow and myocardial perfusion in primary percutaneous coronary intervention.

Authors:  Bin-quan Zhou; Seung-jea Tahk
Journal:  J Zhejiang Univ Sci B       Date:  2007-08       Impact factor: 3.066

2.  Effects of distal protection on left ventricular function in acute anterior myocardial infarction: a Doppler echocardiographic study.

Authors:  Yun-Yan Duan; Hai-Bin Zhang; Li-Wen Liu; Xiao-Dong Zhou; Cheng-Xiang Li; Jun Li; Ting Zhu; Hai-Li Su; Yong-Sheng Zhu; Hong-Ling Li; Jun Zhang
Journal:  Int J Cardiovasc Imaging       Date:  2009-10-04       Impact factor: 2.357

3.  Thrombosuction utilizing an export aspiration catheter during primary percutaneous coronary intervention in acute myocardial infarction.

Authors:  Woong Chol Kang; Tae Hoon Ahn; Seung Hwan Han; Wook-Jin Chung; Mi Seung Shin; Kwang Kon Koh; In Suck Choi; Eak Kyun Shin
Journal:  Yonsei Med J       Date:  2007-04-30       Impact factor: 2.759

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.