INTRODUCTION: In recent years, a number of rotary nickel titanium (NiTi) systems have been developed to provide better, faster, and easier cleaning and shaping of the root canal system. Although the NiTi instruments are more flexible than the stainless steel files, the main problem with the rotary NiTi instruments is the failure of the instruments. The aim of this study was to evaluate the deformation and fracture rate of Mtwo rotary nickel-titanium instruments (VDW, Munich, Germany) discarded after routine clinical use.
METHODS: A total of 593 Mtwo rotary NiTi instruments were collected after clinical use from the clinic of endodontics over 12 months. The length of the files was measured using a digital caliper to determine any fracture, and then all the files were evaluated under a stereomicroscope for defects such as unwinding, curving, or bending and fracture. The fracture faces of separated files were also evaluated under a scanning electron microscope. The data were analyzed using a chi-square and z test.
RESULTS: A percentage of all files (25.80%) showed defects, and the major defect was fracture (16.02%). The most frequently fractured file was #10.04 (30.39%). Deformations without fracture were mostly observed on #15.05 files (25.47%).
CONCLUSIONS: A higher rate of deformation was observed for #10.04 and #15.05 files. Therefore, these files should be considered as single-use instruments. Because cyclic fatigue was the cause of 71.58% of the instrument fractures, it is also important not to exceed the maximum number of usage recommended by the manufacturer and discard the instruments on a regular basis.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19801238     DOI: 10.1016/j.joen.2009.06.014

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  17 in total

1.  Cyclic fatigue resistance of Mtwo NiTi rotary instruments used by experienced and novice operators--an in vivo and in vitro study.

Authors:  Gianluca Plotino; Dina Al-Sudani; Stefano Pulino; Nicola M Grande; Piero Alessandro Marcoli; Silvia Pizzi; Luca Testarelli; Gianluca Gambarini
Journal:  Med Sci Monit       Date:  2012-06

2.  Comparing the Fracture Rate of Hero 642, FlexMaster and Mtwo in the Simulated Canals.

Authors:  Hosein Labaf; Roza Haghgoo; Kiumars Nazarimoghadam; Mahshid Mohamadibasir
Journal:  Iran Endod J       Date:  2014-03-08

3.  The evaluation of two rotary instrumentation techniques under "operator-related variables" standardized conditions.

Authors:  Ozgur Uzun; Ozgur Topuz; Fatma Yalpi; Feyza Unsal; Cumhur Aydin; Emre Bodrumlu
Journal:  Eur J Dent       Date:  2013-10

4.  Canal preparation with nickel-titanium or stainless steel instruments without the risk of instrument fracture: preliminary observations.

Authors:  Ghassan Yared
Journal:  Restor Dent Endod       Date:  2014-11-13

5.  Evaluation of the Fractured Surface of Five Endodontic Rotary Instruments: A Metallurgical Study.

Authors:  Mohsen Aminsobhani; Mohamad Saleh Khalatbari; Naghmeh Meraji; Abdollah Ghorbanzadeh; Ehsan Sadri
Journal:  Iran Endod J       Date:  2016

6.  Incidence of Deformation and Fracture of Twisted File Adaptive Instruments after Repeated Clinical Use.

Authors:  Gianluca Gambarini; Lucila Piasecki; Dario Di Nardo; Gabriele Miccoli; Gianni Di Giorgio; Everdan Carneiro; Dina Al-Sudani; Luca Testarelli
Journal:  J Oral Maxillofac Res       Date:  2016-12-28

7.  The Effect of Hydrofluoric Acid Surface Treatment on the Cyclic Fatigue Resistance of K3 NiTi Instruments.

Authors:  Kee-Yeon Kum; Seok Woo Chang
Journal:  Bioinorg Chem Appl       Date:  2017-05-02       Impact factor: 7.778

8.  Experimental evaluation of cyclic fatigue resistance of four different nickel-titanium instruments after immersion in sodium hypochlorite and/or sterilization.

Authors:  Üreyen Kaya Bulem; Ayse Diljin Kececi; Hilmi Egemen Guldas
Journal:  J Appl Oral Sci       Date:  2013 Nov-Dec       Impact factor: 2.698

9.  Comparison of cleaning efficiency and deformation characteristics of Twisted File and ProTaper rotary instruments.

Authors:  Hang Li; Chenzheng Zhang; Qing Li; Changning Wang; Yaling Song
Journal:  Eur J Dent       Date:  2014-04

10.  Cyclic Fatigue Resistance of Mtwo Rotary Instruments with two Different Instrumentation Techniques.

Authors:  Sílvio Emanuel Acioly Conrado de Menezes; Shirley Machado Batista; Diego Felipe Brandão de Magalhães; de Albuquerque Diana Santana; Gabriela Queiroz de Melo Monteiro
Journal:  Iran Endod J       Date:  2018
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.