Seung Hwan Han1, Woong Chol Kang, Tae Hoon Ahn, Eak Kyun Shin.
Abstract
Distal protection devices such as FilterWire EX have been widely used in carotid artery stenting, however, the large amount of atherothrombotic debris entrapped in the filter could reduce or stop antegrade flow. We present a case of pseudo-no-reflow phenomenon after postdilatation of the stent in a patient with asymptomatic carotid artery stenosis. After several passes using an Export Aspiration catheter, normal flow in the internal carotid artery was restored. Aspiration thrombectomy can successfully recover pseudo-no-reflow phenomenon.Entities:
Keywords: Aspiration Thrombectomy; Carotid Artery Stenting; Distal Protection Device; Pseudo-no Reflow Phenomenon
Mesh:
Year: 2009 PMID: 19795002 PMCID: PMC2752787 DOI: 10.3346/jkms.2009.24.5.967
Source DB: PubMed Journal: J Korean Med Sci ISSN: 1011-8934 Impact factor: 2.153