Literature DB >> 11869850

Multicenter evaluation of carotid artery stenting with a filter protection system.

Nadim Al-Mubarak1, Antonio Colombo, Peter A Gaines, Sriram S Iyer, Nicola Corvaja, Trevor J Cleveland, Sumaira Macdonald, Cristina Brennan, Jiri J Vitek.   

Abstract

OBJECTIVES: The aim of this study was to evaluate the feasibility and safety of carotid artery stenting (CAS) with a filter protection system.
BACKGROUND: Neurologic events linked to the embolization of particulate matter to the cerebral circulation may complicate CAS. Strategies designed to capture embolic particles during carotid intervention are being evaluated for their efficacy in reducing the risk of these events.
METHODS: Between September 1999 and July 2001, a total of 162 patients (164 hemispheres) underwent CAS with filter protection (NeuroShield, MedNova Ltd., Galway, Ireland) according to prospective protocols evaluating the filter system at three institutions.
RESULTS: Angiographic success was achieved in 162 of the procedures (99%) and filter placement was successful in 154 (94%) procedures. Carotid access was unsuccessful in two cases (1%) and filter placement in eight cases (5%). Of the latter, five procedures were completed with no protection and three were completed using alternative protection devices. On an intention-to-treat basis, the overall combined 30-day rate of all-stroke and death was 2% (four events: two minor strokes and two deaths). This includes one minor stroke in a patient with failed filter placement and CAS completed without protection. There was one cardiac arrhythmic death and one death from hyperperfusion-related intracerebral hemorrhage. There were no major embolic strokes.
CONCLUSIONS: Carotid artery stenting with filter protection is technically feasible and safe. Early clinical outcomes appear to be favorable and need to be confirmed in a larger comparative study.

Entities:  

Mesh:

Year:  2002        PMID: 11869850     DOI: 10.1016/s0735-1097(02)01692-3

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  20 in total

1.  Quality improvement guidelines for the performance of cervical carotid angioplasty and stent placement.

Authors:  John D Barr; John J Connors; David Sacks; Joan C Wojak; Gary J Becker; John F Cardella; Bohdan Chopko; Jacques E Dion; Allan J Fox; Randall T Higashida; Robert W Hurst; Curtis A Lewis; Terence A S Matalon; Gary M Nesbit; J Arliss Pollock; Eric J Russell; David J Seidenwurm; Robert C Wallace
Journal:  AJNR Am J Neuroradiol       Date:  2003 Nov-Dec       Impact factor: 3.825

Review 2.  Carotid artery stenting.

Authors:  Francesco Liistro; Carlo Di Mario
Journal:  Heart       Date:  2003-08       Impact factor: 5.994

Review 3.  [Distal protection devices in carotid stent].

Authors:  J Berkefeld; R du Mesnil de Rochemont; M Sitzer; F E Zanella
Journal:  Radiologe       Date:  2004-10       Impact factor: 0.635

4.  Carotid artery stenting with distal filter protection: single-center experience in high-surgical-risk patients.

Authors:  Rainer Knur
Journal:  Heart Vessels       Date:  2010-10-30       Impact factor: 2.037

5.  Stent-graft treatment of extracranial internal carotid artery aneurysm.

Authors:  Robert Juszkat; Maciej Wróbel; Wojciech Golusiński; Witold Szyfter; Paweł Checiński; Grzegorz Oszkinis
Journal:  Eur Arch Otorhinolaryngol       Date:  2005-03-01       Impact factor: 2.503

Review 6.  Therapeutic advances in interventional neurology.

Authors:  Jawad F Kirmani; Nazli Janjua; Ammar Al Kawi; Shafiuddin Ahmed; Ismail Khatri; Ali Ebrahimi; Afshin A Divani; Adnan I Qureshi
Journal:  NeuroRx       Date:  2005-04

7.  Carotid artery stent placement with distal balloon protection: technical considerations.

Authors:  Jiri J Vitek; Nadim Al-Mubarak; Sriram S Iyer; Gary S Roubin
Journal:  AJNR Am J Neuroradiol       Date:  2005-04       Impact factor: 3.825

Review 8.  [Treatment of arteriosclerotic diseases of the carotid artery. The carotid stent].

Authors:  I Q Grunwald; P Papanagiotou; C Roth; K M Hartmann; F Ahlhelm; W Reith
Journal:  Radiologe       Date:  2008-07       Impact factor: 0.635

9.  Locking between a cerebral protection device and a stent-delivering catheter during carotid artery stenting.

Authors:  Jong Hun Lee; Sung Won Youn; Ho Kyun Kim
Journal:  Interv Neuroradiol       Date:  2014-02-10       Impact factor: 1.610

10.  Initial experience of using the filter protection device during carotid artery stenting in Japan.

Authors:  Katsutoshi Takayama; Hiroyuki Nakagawa; Satoru Iwasaki; Toshiaki Taoka; Toshiteru Miyasaka; Kaoru Myouchin; Takeshi Wada; Masahiko Sakamoto; Akio Fukusumi; Ichiro Nakagawa; Shinichiro Kurokawa; Kimihiko Kichikawa
Journal:  Radiat Med       Date:  2008-08-03
View more