Literature DB >> 19793138

Optimized measurement of activation rate at left atrial sites with complex fractionated electrograms during atrial fibrillation.

Edward J Ciaccio1, Angelo B Biviano, William Whang, Andrew L Wit, James Coromilas, Hasan Garan.   

Abstract

BACKGROUND: Complex fractionated atrial electrograms (CFAE) have become targets for catheter ablation of atrial fibrillation (AF). Frequency components of AF signals have also become important markers for identifying potential mechanisms of AF, yet inaccuracies exist, particularly in standard dominant frequency (SDF) calculations especially at CFAE sites. We developed new methodology to improve accuracy of AF rate determinations at such recording sites.
OBJECTIVE: To develop optimal methods for estimating activation rates in paroxysmal and persistent AF.
METHODS: Electrograms were obtained from one right atrial, coronary sinus, and 6 left atrial (LA) endocardial regions manifesting CFAEs in paroxysmal (N = 7) and persistent (N = 7) AF patients. SDF was measured from 8.4 s intervals and compared to (1) optimized DF (ODF) calculated by optimizing the filter coefficients which maximized dominant frequency power, (2) autocorrelation (AC), with the rate estimated as the inverse of the signal phase shift generating the largest autocorrelation coefficient, and (3) ensemble average (EA), with the rate estimated by summing successive signal segments and selecting segment length yielding maximum power. Rate measurements were compared between groups, at baseline and with additive interference, having similar frequency content to the electrograms, to test the robustness of the different methods.
RESULTS: From pooled data (N = 168 recording sites), a significantly higher LA dominant frequency was found in persistent versus paroxysmal patients using each method (P < 0.001), with a mean value for all methods of 6.23 +/- 0.08 Hz versus 5.32 +/- 0.10 Hz, respectively. At the highest additive interference level, the rate measurement error was significantly greater in SDF as compared with EA (P = 0.010) and ODF (P = 0.035), and at all interference levels SDF had the largest error of any method.
CONCLUSIONS: SDF appears less robust to additive interference, compared to the ODF and EA methods of estimating the activation rate at CFAE sites in this small group of patients. Use of optimized filter coefficients for DF measurement, or use of correlative methods such as EA, that reinforce the signal rather than filtering the noise, may improve calculation of activation rates.

Entities:  

Mesh:

Year:  2009        PMID: 19793138     DOI: 10.1111/j.1540-8167.2009.01595.x

Source DB:  PubMed          Journal:  J Cardiovasc Electrophysiol        ISSN: 1045-3873


  12 in total

Review 1.  Ablation of Longstanding Persistent Atrial Fibrillation.

Authors:  Edward J Ciaccio
Journal:  J Atr Fibrillation       Date:  2010-10-22

2.  Comparison of spectral estimators for characterizing fractionated atrial electrograms.

Authors:  Edward J Ciaccio; Angelo B Biviano; Hasan Garan
Journal:  Biomed Eng Online       Date:  2013-07-16       Impact factor: 2.819

3.  Differences in repeating patterns of complex fractionated left atrial electrograms in longstanding persistent atrial fibrillation as compared with paroxysmal atrial fibrillation.

Authors:  Edward J Ciaccio; Angelo B Biviano; William Whang; John A Vest; Alok Gambhir; Andrew J Einstein; Hasan Garan
Journal:  Circ Arrhythm Electrophysiol       Date:  2011-05-02

4.  Complex fractionated atrial electrograms: is this the beast to tame in atrial fibrillation?

Authors:  Omer Berenfeld; José Jalife
Journal:  Circ Arrhythm Electrophysiol       Date:  2011-08

5.  Different characteristics of complex fractionated atrial electrograms in acute paroxysmal versus long-standing persistent atrial fibrillation.

Authors:  Edward J Ciaccio; Angelo B Biviano; William Whang; Alok Gambhir; Hasan Garan
Journal:  Heart Rhythm       Date:  2010-06-15       Impact factor: 6.343

6.  Temporal stability in the spectral representation of complex fractionated atrial electrograms.

Authors:  Edward J Ciaccio; Angelo B Biviano; Alok Gambhir; Jason T Jacobson; Hasan Garan
Journal:  Pacing Clin Electrophysiol       Date:  2013-08-26       Impact factor: 1.976

7.  Spectral profiles of complex fractionated atrial electrograms are different in longstanding and acute onset atrial fibrillation atrial electrogram spectra.

Authors:  Edward J Ciaccio; Angelo B Biviano; William Whang; Alok Gambhir; Hasan Garan
Journal:  J Cardiovasc Electrophysiol       Date:  2012-05-11

8.  Improved frequency resolution for characterization of complex fractionated atrial electrograms.

Authors:  Edward J Ciaccio; Angelo B Biviano; William Whang; Hasan Garan
Journal:  Biomed Eng Online       Date:  2012-04-03       Impact factor: 2.819

9.  A new transform for the analysis of complex fractionated atrial electrograms.

Authors:  Edward J Ciaccio; Angelo B Biviano; William Whang; James Coromilas; Hasan Garan
Journal:  Biomed Eng Online       Date:  2011-05-12       Impact factor: 2.819

10.  Robust spectral analysis of videocapsule images acquired from celiac disease patients.

Authors:  Edward J Ciaccio; Christina A Tennyson; Govind Bhagat; Suzanne K Lewis; Peter H R Green
Journal:  Biomed Eng Online       Date:  2011-09-09       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.