Literature DB >> 1979092

Inaccuracy of the Hawksley random zero sphygmomanometer.

E O'Brien1, F Mee, N Atkins, K O'Malley.   

Abstract

To examine the accuracy of the Hawksley random zero sphygmomanometer two studies were done with subjects with a wide range of blood pressure. When readings made by one observer on the UK model of the Hawksley sphygmomanometer were compared with readings by two independent observers on separate mercury sphygmomanometers, the Hawksley device underestimated systolic readings by a mean (SD) of 2.0 (2.4) and 0.5 (3.6) mm Hg and diastolic readings by a mean of 3.7 (2.7) and 2.8 (2.9) mm Hg. When readings made on the UK and US models of the Hawksley sphygmomanometer were compared with those made on mercury sphygmomanometers, with observers exchanging devices half way during the experiment, the UK Hawksley device underestimated systolic pressure by a mean of 3.8 (SD 3.5) mm Hg and diastolic blood pressure by 7.5 (3.8) mm Hg; and the US model by 2.6 (3.4) mm Hg for systolic pressure and 6.2 (3.7) mm Hg for diastolic pressure. There was better agreement between two observers using standard sphygmomanometers than between an observer using the Hawksley random zero sphygmomanometer and an observer using a standard sphygmomanometer. Thus, the quantitative aspects of blood pressure in epidemiological and intervention studies in which the Hawksley random zero sphygmomanometer was used need re-evaluation. Moreover, the Hawksley random zero sphygmomanometer, in its present design, should not be used in hypertension research.

Entities:  

Mesh:

Year:  1990        PMID: 1979092     DOI: 10.1016/0140-6736(90)93177-q

Source DB:  PubMed          Journal:  Lancet        ISSN: 0140-6736            Impact factor:   79.321


  23 in total

1.  Blood pressure measuring devices: recommendations of the European Society of Hypertension.

Authors:  E O'Brien; B Waeber; G Parati; J Staessen; M G Myers
Journal:  BMJ       Date:  2001-03-03

2.  Prevalence and control of arterial hypertension in the south-east of Spain: a radical but still insufficient improvement.

Authors:  M J Tormo; C Navarro; M D Chirlaque; D Pérez-Flores
Journal:  Eur J Epidemiol       Date:  1997-04       Impact factor: 8.082

3.  Home blood pressure monitoring in diabetes.

Authors:  C Gompels; D Savage
Journal:  Arch Dis Child       Date:  1992-05       Impact factor: 3.791

4.  [Prevalence of arterial hypertension in the population of Western Germany: Heinz Nixdorf Recall Study].

Authors:  M Horacek; S Möhlenkamp; A A Mahabadi; S Churzidse; S Moebus; K-H Jöckel; R Erbel
Journal:  Herz       Date:  2012-11       Impact factor: 1.443

5.  The Dinamap 1846SX automated blood pressure recorder: comparison with the Hawksley random zero sphygmomanometer under field conditions.

Authors:  P H Whincup; N G Bruce; D G Cook; A G Shaper
Journal:  J Epidemiol Community Health       Date:  1992-04       Impact factor: 3.710

6.  Blood pressure measurement in pregnancy: the effect of arm circumference and sphygmomanometer cuff size.

Authors:  Chye L Kho; Mark A Brown; Sharon L H Ong; George J Mangos
Journal:  Obstet Med       Date:  2009-09-01

7.  The Hawksley random zero sphygmomanometer. Repeat experiment exonerates instrument.

Authors:  J Garrow; C Summerbell
Journal:  BMJ       Date:  1993-07-10

8.  Measurement error in the Hawksley random zero sphygmomanometer: what damage has been done and what can we learn?

Authors:  R M Conroy; E O'Brien; K O'Malley; N Atkins
Journal:  BMJ       Date:  1993-05-15

9.  Prevalence, Determinants, and Clinical Significance of Masked Hypertension in a Population-Based Sample of African Americans: The Jackson Heart Study.

Authors:  Keith M Diaz; Praveen Veerabhadrappa; Michael D Brown; Matthew C Whited; Patricia M Dubbert; DeMarc A Hickson
Journal:  Am J Hypertens       Date:  2014-12-12       Impact factor: 2.689

10.  The effects of weight loss and salt reduction on visit-to-visit blood pressure variability: results from a multicenter randomized controlled trial.

Authors:  Keith M Diaz; Paul Muntner; Emily B Levitan; Michael D Brown; Dianne M Babbitt; Daichi Shimbo
Journal:  J Hypertens       Date:  2014-04       Impact factor: 4.844

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.