Literature DB >> 19790183

The efficacy of postoperative monitoring: a single surgeon comparison of clinical monitoring and the implantable Doppler probe in 547 consecutive free flaps.

Warren M Rozen1, Daniel Chubb, Iain S Whitaker, Rafael Acosta.   

Abstract

BACKGROUND: An important element in achieving high success rates with free flap surgery has been the use of different techniques for monitoring flaps postoperatively as a means to detecting vascular compromise. Successful monitoring of the vascular pedicle to a flap can potentiate rapid return to theater in the setting of compromise, with the potential to salvage the flap. There is little evidence that any technique offers any advantage over clinical monitoring alone.
METHODS: A consecutive series of 547 patients from a single plastic surgical unit who underwent a fasciocutaneous free flap operation for breast reconstruction [deep inferior epigastric artery perforator (DIEP) flap, superficial inferior epigastric artery (SIEA) flap, or superior gluteal artery perforator (SGAP) flap] were included. A comparison was made between the first 426 consecutive patients in whom flap monitoring was performed using clinical monitoring alone and the subsequent 121 patients in whom monitoring was achieved with the Cook-Swartz implantable Doppler probe. Outcome measures included flap salvage rate and false-positive rate.
RESULTS: There was a strong trend toward improved salvage rates with the implantable Doppler probe compared with clinical monitoring (80% vs. 66%, P = 0.48). When combined with the literature (meta-analysis), the data prove statistically significant (P < 0.01). There was no statistical difference between the groups for false-positive rates.
CONCLUSION: Flap monitoring with the implantable Doppler probe can improve flap salvage rates without increasing the rate of false-positive takebacks. Copyright 2009 Wiley-Liss, Inc. Microsurgery, 2010.

Entities:  

Mesh:

Year:  2010        PMID: 19790183     DOI: 10.1002/micr.20706

Source DB:  PubMed          Journal:  Microsurgery        ISSN: 0738-1085            Impact factor:   2.425


  15 in total

1.  Bone flap perfusion assessment using near-infrared fluorescence imaging.

Authors:  John T Nguyen; Yoshitomo Ashitate; Ian A Buchanan; Ahmed M S Ibrahim; Sylvain Gioux; Priti P Patel; John V Frangioni; Bernard T Lee
Journal:  J Surg Res       Date:  2012-05-24       Impact factor: 2.192

Review 2.  Postoperative Free-Flap Monitoring Techniques.

Authors:  Scott Kohlert; Alexandra E Quimby; Masoud Saman; Yadranko Ducic
Journal:  Semin Plast Surg       Date:  2019-03-08       Impact factor: 2.314

3.  The venous anatomy of the abdominal wall for Deep Inferior Epigastric Artery (DIEP) flaps in breast reconstruction.

Authors:  Warren M Rozen; Mark W Ashton
Journal:  Gland Surg       Date:  2012-08

4.  Postoperative monitoring of free flap reconstruction: A comparison of external Doppler ultrasonography and the implantable Doppler probe.

Authors:  Rayaad C Hosein; Agustin Cornejo; Howard T Wang
Journal:  Plast Surg (Oakv)       Date:  2016       Impact factor: 0.947

Review 5.  [A systematic approach to plastic surgical foot reconstruction].

Authors:  Susanne Rein; Thomas Kremer
Journal:  Unfallchirurg       Date:  2021-09-09       Impact factor: 1.000

6.  Intramuscular Near-Infrared Spectroscopy for Muscle Flap Monitoring in a Porcine Model.

Authors:  Wubin Bai; Hexia Guo; Wei Ouyang; Yang Weng; Changsheng Wu; Yihan Liu; Hao Zang; Lauren Jacobson; Yameng Xu; Di Lu; Ziying Hu; Shuo Li; Hany M Arafa; Quansan Yang; Amanda M Westman; Matthew R MacEwan; John A Rogers; Mitchell A Pet
Journal:  J Reconstr Microsurg       Date:  2021-09-22       Impact factor: 2.329

Review 7.  Consensus Review of Optimal Perioperative Care in Breast Reconstruction: Enhanced Recovery after Surgery (ERAS) Society Recommendations.

Authors:  Claire Temple-Oberle; Melissa A Shea-Budgell; Mark Tan; John L Semple; Christiaan Schrag; Marcio Barreto; Phillip Blondeel; Jeremy Hamming; Joseph Dayan; Olle Ljungqvist
Journal:  Plast Reconstr Surg       Date:  2017-05       Impact factor: 5.169

8.  Implantable Doppler Probes for Postoperatively Monitoring Free Flaps: Efficacy. A Systematic Review and Meta-analysis.

Authors:  Tzu-Yen Chang; Yao-Chou Lee; You-Cheng Lin; Stanley Thian-Sze Wong; Yuan-Yu Hsueh; Yao-Lung Kuo; Shyh-Jou Shieh; Jing-Wei Lee
Journal:  Plast Reconstr Surg Glob Open       Date:  2016-11-28

9.  The efficacy of the Cook-Swartz implantable Doppler in the detection of free-flap compromise: a systematic review protocol.

Authors:  Riaz A Agha; Buket Gundogan; Alexander J Fowler; Thomas W H Bragg; Dennis P Orgill
Journal:  BMJ Open       Date:  2014-03-12       Impact factor: 2.692

10.  Predictors of Reoperations in Deep Inferior Epigastric Perforator Flap Breast Reconstruction.

Authors:  Dmytro Unukovych; Camilo Hernandez Gallego; Helena Aineskog; Andres Rodriguez-Lorenzo; Maria Mani
Journal:  Plast Reconstr Surg Glob Open       Date:  2016-08-29
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.