Literature DB >> 19788043

Assessment of the accuracy and precision of a patient immobilization device for radiation therapy in canine head and neck tumors.

Michael S Kent1, Ira K Gordon, Ines Benavides, Paul Primas, Jacque Young.   

Abstract

The positioning accuracy and precision of a head and neck immobilization device for radiation therapy of tumors in the canine skull was evaluated. Nineteen dogs with a spontaneous tumor of the head were enrolled including 12 with an intracranial mass and seven with an intranasal or maxillary tumor. Three hundred thirty-three pairs of orthogonal digital portal radiographs were analyzed to assess patient displacement in the cranial-caudal, lateral, and dorso-ventral directions. The mean systematic displacement was 0.8, 1, and 0.9 mm. The mean random displacement was 1.9, 1.6, and 1.5 mm. These values resulted in an overall displacement of 2.1 mm in the cranial-caudal direction, 1.8mm in the lateral direction, and 1.7 mm in the dorsal-ventral direction. The mean displacement value of the three dimensional (3D) vector was 2.4 mm with a standard deviation of 2.1. Ninety-five percent of all vectors were < 6.4 mm. This study quantifies the precision and accuracy of this particular positioning device. Knowing the limitations and setup variability of the system being used to set patients up for daily radiotherapy is paramount to planning and delivering appropriate radiation doses, especially as more complex treatment methods are used.

Entities:  

Mesh:

Year:  2009        PMID: 19788043     DOI: 10.1111/j.1740-8261.2009.01583.x

Source DB:  PubMed          Journal:  Vet Radiol Ultrasound        ISSN: 1058-8183            Impact factor:   1.363


  4 in total

1.  Helical tomotherapy setup variations in canine nasal tumor patients immobilized with a bite block.

Authors:  Lyndsay N Kubicek; Songwon Seo; Richard J Chappell; Robert Jeraj; Lisa J Forrest
Journal:  Vet Radiol Ultrasound       Date:  2012-06-25       Impact factor: 1.363

2.  Treatment of MRI-Diagnosed Trigeminal Peripheral Nerve Sheath Tumors by Stereotactic Radiotherapy in Dogs.

Authors:  K S Hansen; A L Zwingenberger; A P Théon; I Pfeiffer; M S Kent
Journal:  J Vet Intern Med       Date:  2016-06-08       Impact factor: 3.333

3.  Accuracy and Precision of a Veterinary Neuronavigation System for Radiation Oncology Positioning.

Authors:  Isabelle F Vanhaezebrouck; Elizabeth A Ballegeer; Stephen Frey; Rob Sieffert
Journal:  J Vet Med       Date:  2018-02-13

Review 4.  Imaging in Non-neurologic Oncologic Treatment Planning of the Head and Neck.

Authors:  Katherine S Hansen; Michael S Kent
Journal:  Front Vet Sci       Date:  2019-03-28
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.