Literature DB >> 19784626

Meniscal repair using the FasT-Fix device in patients with chronic meniscal lesions.

Dragos Popescu1, Sergi Sastre, Miguel Caballero, Jin Woo Kim Lee, Ignasi Claret, Montserrat Nuñez, Luis Lozano.   

Abstract

The aim of this prospective study was to evaluate meniscal suturing using the FasT-Fix device for chronic meniscal tears. This procedure was carried out on 25 patients between 2006 and 2007. Nineteen patients were male and the median age was 31 (14-47) years. The median waiting time to surgery was 27 (6-80) months and the median follow-up was 20 (14-29) months. Eleven patients (44%) required reconstruction of an associated anterior cruciate ligament (ACL) injury. 20 patients (80%) showed medial meniscus tears. All tears were located in the red zone or red-white zone. According to Barett's criteria, meniscal tear healing was achieved in 21 patients (84%). Lysholm and Tegner scale scores improved from 60 (47-77) preoperatively to 95 (58-100) postoperatively and from 3 (2-6) preoperatively to 6 (3-9) postoperatively, respectively. There were no neurovascular complications. Revision surgery was necessary in one patient, in whom a partial meniscectomy was performed. The results obtained suggest that chronic meniscal tears in the zones described can be healed.

Entities:  

Mesh:

Year:  2009        PMID: 19784626     DOI: 10.1007/s00167-009-0926-6

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  23 in total

1.  Chondral injury following meniscal repair with a biodegradable implant.

Authors:  K Anderson; R G Marx; J Hannafin; R F Warren
Journal:  Arthroscopy       Date:  2000-10       Impact factor: 4.772

2.  A biomechanical comparison of the FasT-Fix meniscal repair suture system and the RapidLoc device in cadaver meniscus.

Authors:  Yavuz Kocabey; Haw Chong Chang; Jeff C Brand; Akbar Nawab; John Nyland; David N M Caborn
Journal:  Arthroscopy       Date:  2006-04       Impact factor: 4.772

3.  A cyclic testing comparison of FasT-Fix and RapidLoc devices in human cadaveric meniscus.

Authors:  J Nyland; H Chang; Y Kocabey; A Nawab; J Brand; D N M Caborn
Journal:  Arch Orthop Trauma Surg       Date:  2007-12-20       Impact factor: 3.067

4.  FasT-Fix meniscal repair: mid-term results.

Authors:  F Alan Barber; F Alexander Schroeder; Fernando Barrera Oro; R Cole Beavis
Journal:  Arthroscopy       Date:  2008-10-10       Impact factor: 4.772

5.  Failure strengths of suture versus biodegradable arrow for meniscal repair: an in vitro study.

Authors:  G F Dervin; K J Downing; G C Keene; D G McBride
Journal:  Arthroscopy       Date:  1997-06       Impact factor: 4.772

6.  Aseptic synovitis after meniscal repair using the biodegradable meniscus arrow.

Authors:  E K Song; K B Lee; T R Yoon
Journal:  Arthroscopy       Date:  2001-01       Impact factor: 4.772

7.  Rating systems in the evaluation of knee ligament injuries.

Authors:  Y Tegner; J Lysholm
Journal:  Clin Orthop Relat Res       Date:  1985-09       Impact factor: 4.176

8.  Meniscal repair using the FasT-Fix all-inside meniscal repair device.

Authors:  Andrew L Haas; Anthony A Schepsis; Joshua Hornstein; Cory M Edgar
Journal:  Arthroscopy       Date:  2005-02       Impact factor: 4.772

9.  Comparison of arthroscopic meniscal repair results using 3 different meniscal repair devices in anterior cruciate ligament reconstruction patients.

Authors:  Alkiviadis Kalliakmanis; Sarantos Zourntos; Dimitrios Bousgas; Pantelis Nikolaou
Journal:  Arthroscopy       Date:  2008-05-05       Impact factor: 4.772

10.  Meniscal healing after meniscal repair: a CT arthrography assessment.

Authors:  Nicolas Pujol; Ludovico Panarella; Tarik Ait Si Selmi; Philippe Neyret; Donald Fithian; Philippe Beaufils
Journal:  Am J Sports Med       Date:  2008-05-15       Impact factor: 6.202

View more
  8 in total

1.  Cyst following meniscal repair.

Authors:  Vinay Kulkarni; Jonathan Mulford
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-12-08       Impact factor: 4.342

Review 2.  All-inside meniscal repair using the FasT-Fix meniscal repair system: is still needed to avoid weight bearing? A systematic review.

Authors:  Alberto Vascellari; Enrico Rebuzzi; Stefano Schiavetti; Nicolò Coletti
Journal:  Musculoskelet Surg       Date:  2012-07-07

3.  Long-term outcome after meniscal repair.

Authors:  Mike Tengrootenhuysen; Geert Meermans; Kathleen Pittoors; Roger van Riet; Jan Victor
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-10-15       Impact factor: 4.342

4.  Long-term follow-up of bucket-handle meniscal repairs: chondroprotective effect outweighs high failure risk.

Authors:  George Kalifis; Vasilios Raoulis; Frideriki Panteliadou; Athanasios Liantsis; Riccardo D'Ambrosi; Michael Hantes
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2021-11-06       Impact factor: 4.342

5.  Comparison of new and old all-inside suture devices in meniscal cyst formation rates after meniscal repair.

Authors:  Takuya Kinoshita; Yusuke Hashimoto; Kazuya Nishino; Yohei Nishida; Shinji Takahashi; Hiroaki Nakamura
Journal:  Int Orthop       Date:  2022-03-15       Impact factor: 3.479

6.  MR-arthrography assessment after repair of chronic meniscal tears.

Authors:  Dragos Popescu; Sergi Sastre; Ana Isabel Garcia; Xavier Tomas; Diego Reategui; Miguel Caballero
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-06-05       Impact factor: 4.342

7.  Meniscal repair by all-inside technique with Fast-Fix device.

Authors:  Leonardo José Bernardes Albertoni; Felipe Conrado Schumacher; Matheus Henrique Araújo Ventura; Carlos Eduardo da Silveira Franciozi; Pedro Debieux; Marcelo Seiji Kubota; Geraldo Sérgio de Mello Granata; Marcus Vinícius Malheiros Luzo; Antônio Altenor Bessa de Queiroz; Mario Carneiro Filho
Journal:  Rev Bras Ortop       Date:  2013-10-19

8.  Predictive Factors for Failure of Meniscal Repair: A Retrospective Dual-Center Analysis of 918 Consecutive Cases.

Authors:  Erik Ronnblad; Bjorn Barenius; Bjorn Engstrom; Karl Eriksson
Journal:  Orthop J Sports Med       Date:  2020-03-27
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.