Literature DB >> 18094981

A cyclic testing comparison of FasT-Fix and RapidLoc devices in human cadaveric meniscus.

J Nyland1, H Chang, Y Kocabey, A Nawab, J Brand, D N M Caborn.   

Abstract

INTRODUCTION: Cyclic testing may provide a more valid depiction of how arthroscopic meniscal repairs will withstand the forces of activities of daily living (ADLs) and therapeutic exercises early post-surgery than single cycle load to failure testing. This study compared the meniscal fixation provided by vertically or horizontally placed FasT-Fix devices to horizontally placed RapidLoc devices under submaximal cyclic test conditions.
MATERIALS AND METHODS: Eighteen human cadaveric menisci were divided into three groups of six specimens. A scalpel was used to create a 2 cm lesion at 3 mm from the outer edge of the posterior third of each specimen. Merselene tape loops were placed around each side of the lesion and the tears were repaired using two vertical FasT-Fix, two horizontal FasT-Fix, or two RapidLoc devices. Cyclic testing (5-50 N at 1 Hz for 500 cycles) was performed on a servo hydraulic device. One-way ANOVA and Scheffe post-hoc tests were used to evaluate group differences (P < 0.05).
RESULTS: The vertical FasT-Fix group had less displacement over the initial ten loading cycles compared to the RapidLoc group (P = 0.004), but did not differ from the horizontal FasT-Fix group (P = 0.07). At 50, 100, 200, 300, 400, and 500 cycles, the vertical FasT-Fix group had less displacement than the horizontal FasT-Fix or RapidLoc groups (P < or = 0.004). At each interval the vertical FasT-Fix group had greater relative stiffness than the other groups (P < or = 0.009).
CONCLUSIONS: The vertical FasT-Fix group had comparatively less displacement (primarily repair site gapping) and greater relative stiffness.

Entities:  

Mesh:

Year:  2007        PMID: 18094981     DOI: 10.1007/s00402-007-0545-y

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  4 in total

1.  Meniscal repair using large diameter horizontal sutures increases fixation strength: an in vitro study.

Authors:  Yavuz Kocabey; Omer Taşer; Onur Hapa; Aycan Güçlü; Ergun Bozdag; Emin Sünbüloglu; Mahmutnedim Doral
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-07-03       Impact factor: 4.342

2.  Determination of the safe penetration depth during all-inside meniscal repair of the posterior part of the lateral meniscus using the FasT-Fix suture repair system.

Authors:  Mohamed Mahmoud Abouheif; Hayatoshi Shibuya; Takuya Niimoto; Wirat Kongcharoensombat; Masataka Deie; Nobuo Adachi; Mitsuo Ochi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-04-06       Impact factor: 4.342

3.  Meniscal repair using the FasT-Fix device in patients with chronic meniscal lesions.

Authors:  Dragos Popescu; Sergi Sastre; Miguel Caballero; Jin Woo Kim Lee; Ignasi Claret; Montserrat Nuñez; Luis Lozano
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-09-26       Impact factor: 4.342

4.  Arthroscopic repair of the meniscal injury using meniscal repair device.

Authors:  Tang Hengtao; Su Xuntong
Journal:  Indian J Orthop       Date:  2015 Sep-Oct       Impact factor: 1.251

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.