Literature DB >> 19780150

Application of DENSE-MR-elastography to the human heart.

Benjamin Robert1, Ralph Sinkus, Jean-Luc Gennisson, Mathias Fink.   

Abstract

Typically, MR-elastography (MRE) encodes the propagation of monochromatic acoustic waves in the MR-phase images via sinusoidal gradients characterized by a detection frequency equal to the frequency of the mechanical vibration. Therefore, the echo time of a conventional MRE sequence is typically longer than the vibration period which is critical for heart tissue exhibiting a short T(2). Thus, fast acquisition techniques like the so-called fractional encoding of harmonic motions were developed for cardiac applications. However, fractional encoding of harmonic motions is limited since it is two orders of magnitude less sensitive to motion than conventional MRE sequences for low-frequency vibrations. Here, a new sequence is derived from the so-called displacement encoding with stimulated echoes (DENSE) sequence. This sequence is more sensitive to displacement than fractional encoding of harmonic motions, and its spectral specificity is equivalent to conventional MRE sequences. The theoretical spectral properties of this new motion-encoding technique are validated in a phantom and excised pork heart specimen. An excellent agreement is found for the measured displacement fields using classic MRE and displacement encoding with stimulated echoes MRE (8% maximum difference). In addition, initial in vivo results on a healthy volunteer clearly show propagating shear waves at 50 Hz. Thus, displacement encoding with stimulated echoes MRE is a promising technique for motion encoding within short T(2)* materials. (c) 2009 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2009        PMID: 19780150     DOI: 10.1002/mrm.22124

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  17 in total

1.  AN OVERVIEW OF ELASTOGRAPHY - AN EMERGING BRANCH OF MEDICAL IMAGING.

Authors:  Armen Sarvazyan; Timothy J Hall; Matthew W Urban; Mostafa Fatemi; Salavat R Aglyamov; Brian S Garra
Journal:  Curr Med Imaging Rev       Date:  2011-11

2.  Frequency-dependent viscoelastic parameters of mouse brain tissue estimated by MR elastography.

Authors:  E H Clayton; J R Garbow; P V Bayly
Journal:  Phys Med Biol       Date:  2011-03-22       Impact factor: 3.609

Review 3.  Myocardial tagging by cardiovascular magnetic resonance: evolution of techniques--pulse sequences, analysis algorithms, and applications.

Authors:  El-Sayed H Ibrahim
Journal:  J Cardiovasc Magn Reson       Date:  2011-07-28       Impact factor: 5.364

4.  Magnetic resonance elastography as a method to estimate myocardial contractility.

Authors:  Arunark Kolipaka; Shivani R Aggarwal; Kiaran P McGee; Nandan Anavekar; Armando Manduca; Richard L Ehman; Philip A Araoz
Journal:  J Magn Reson Imaging       Date:  2012-02-14       Impact factor: 4.813

5.  MR elastography of human lung parenchyma: technical development, theoretical modeling and in vivo validation.

Authors:  Yogesh K Mariappan; Kevin J Glaser; Rolf D Hubmayr; Armando Manduca; Richard L Ehman; Kiaran P McGee
Journal:  J Magn Reson Imaging       Date:  2011-06       Impact factor: 4.813

6.  Elasticity-based determination of isovolumetric phases in the human heart.

Authors:  Thomas Elgeti; Mark Beling; Bernd Hamm; Jürgen Braun; Ingolf Sack
Journal:  J Cardiovasc Magn Reson       Date:  2010-10-27       Impact factor: 5.364

7.  In vivo, high-frequency three-dimensional cardiac MR elastography: Feasibility in normal volunteers.

Authors:  Arvin Arani; Kevin L Glaser; Shivaram P Arunachalam; Phillip J Rossman; David S Lake; Joshua D Trzasko; Armando Manduca; Kiaran P McGee; Richard L Ehman; Philip A Araoz
Journal:  Magn Reson Med       Date:  2016-01-17       Impact factor: 4.668

Review 8.  Review of MR elastography applications and recent developments.

Authors:  Kevin J Glaser; Armando Manduca; Richard L Ehman
Journal:  J Magn Reson Imaging       Date:  2012-10       Impact factor: 4.813

9.  Ultrafast Harmonic Coherent Compound (UHCC) Imaging for High Frame Rate Echocardiography and Shear-Wave Elastography.

Authors:  Mafalda Correia; Jean Provost; Simon Chatelin; Olivier Villemain; Mickael Tanter; Mathieu Pernot
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-02-15       Impact factor: 2.725

Review 10.  Cardiovascular magnetic resonance elastography: A review.

Authors:  Saad Khan; Faisal Fakhouri; Waqas Majeed; Arunark Kolipaka
Journal:  NMR Biomed       Date:  2017-11-29       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.